Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC accepted |
Tender Value
₹2.6 L
EMD Value
₹6,596
Closing Date
18 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Revathy C V
ffice of the Assistant Engineer, LID-EW Section, Vanimel Grama Panchayat
VANIMEL GRAMA PANCHAYATH RETENDER Vanimel GP Vadayar Kunnu Water scheme-Vanimel Grama Panchayath. Vadayar Kunnu water scheme S0116/24-General Electrical Work-Drinking water project
2025_LSGD_735101_50
04-2024-AE-LID-EW-VNML
Open Tender
Electrical Works
Item Rate
VANIMEL GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹585
Yes
₹6,596
Yes
6 Mar 2025
10 Feb 2025
20 Feb 2025
10 Feb 2025
18 Feb 2025
10 Feb 2025
Amount
Vadayar kunnu
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD212160/2024-2025:Supply , Installation and testing of TP MCB , 40 to 63 A
OD212162/2024-2025:Supply ,installation , testing and commissioning of 3 Phase 10HP submersible motor starter complete with fully automatic star delta starter, protection from Overload , single phasing ,, Phase reversal ,, Phase un balance , ON OFF indication lamps, push buttons, volt meter and ammeter etc. in sheet steel enclosure duly wired in the existing panel board and giving connection etc. as required. LT LK make MU-G15 FASD ( 9-22 A)or equivalent
OD212172/2024-2025:Supply and fixing 50mm (2") GI flange in the existing suction/delivery pipe line using required leak proofing materials etc. as required
OD212173/2024-2025:Supply, laying and fitting 50 mm 80 Sch ASTM pipe with suitable type solvent etc. as required at site,
OD212176/2024-2025:Supply and fixing 50mm 80 Sch ASTM Union Code
OD212178/2024-2025:Supply, installation, testing and commissioning of 2 1/2" Cast Iron Non Return Valve in the existing PVC/ ASTM pipe
OD212181/2024-2025:Supply and providing suitable iron hook grouted on wall for binding the service wire.
OD212182/2024-2025:Supply and providing 32 A HRC fuse holder with suitable nut , bolt etc
OD212183/2024-2025:Supply and providing32 A 2 way neutral link on existing meter board using suitable nut.bolt etc as required.
OD212186/2024-2025:Supply and providing the following types and power rated lamps in the existing fittings as required 9 w, LED bulb
OD212188/2024-2025:Supply and fixing 50mm B class GI pipe as support for hanging submersible motor pump set in open well
OD212193/2024-2025:Supply and fixing 50 mm GM Ball valve in the existing ASTM pipe Zoloto make or equivalent
OD212194/2024-2025:Supply and providing 6 mm stranded steel rope for hanging submersible motor pump set
OD212195/2024-2025:Supply and providing 20-63A offset staggered HRC fuse link
OD212196/2024-2025:Supply and fixing 63 A bakelite fuse holder with necessary bolt and nut etc. as required
OD212198/2024-2025:Supply and installation of dust and vermin proof, 3 phase Syntax meter Board (GS-MB-6535) and to fix KSEB meters, fuse units,CT etc as required including fixing it on wall , making good the damageds colour washing et as required.
OD212201/2024-2025:Providing and fixing 25 mm x 3 mm GI Strip on surface or in recess for connections etc as required.
OD212202/2024-2025:Supply and providing Danger 415 V, 150x100mm Enameled danger plates
OD212203/2024-2025:Painting letters or figures with enamel paint as identification mark to SB,DB panel board etc as required
OD212205/2024-2025:Supply and providing LED indicator lamp (Red, Green, Black, Yellow, Orange colours)in the existing panelboard and giving connectionRed ,Green, Black, Yellow, Orange
OD212206/2024-2025:Supply and providing 25x6 mm brass nut and bolt etc. as required
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.14.24.19:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
OD212410/2024-2025:Supply , installation , testing and commissioning of 3 phase 10 HP vertical open well submersible pump set with a maximum head of 213 metre , discharge 10,500 litre per hour at 158 metre head ( Head range 53 to 213 metre. ) in the existing open well using suitable tools and plants . Deccan make 10DLM/11 model, 11 stage or equivalent.
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
OD355048/2024-2025:Supplying and fixing flat iron clamps made of 40x6mm flat iron clamp of 40cm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
Bidder Name
DINEESH M.P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1178555.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .