Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹14.4 L+₹55,987 (4.04%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹14.7 L+₹84,457 (6.09%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher bidder | |
| 4 | L4₹16.7 L+₹2.8 L (20.1%)Rejected-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Rejected being higher bidder | |
| 5 | L5₹19.7 L+₹5.8 L (41.7%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jun 2023, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIRS AND REPLACEMENT OF LT CABLE LT PANELS AND CHANGEOVER IN TECH AREA AT AF STN JODHPUR
2023_MES_597527_1
8576/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
30 Jun 2023
22 May 2023
21 Jun 2023
22 May 2023
19 Jun 2023
6 Jun 2023
Amount
Disconnecting and taking out unserviceable Power Factor meter range Zero Lag-Unity-Zero Lead of any description and supply, fixing, connecting, testing and commissioning of digital electronic Power Factor meter suitable as per existing specifications of accuracy +-0.01%, auxilary burden of less then 2.5 VA at 230V,Lag/Lead indication on the 14 mm LED display square type 96 mm x 96 mm with adopter including connected wiring with 1.5 Sqmm PVC insulated and sheathed copper conductor cable ( FRLS ) complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable current transformers of 100/5 amps CT ratio of any description and supply, fixing, connecting, testing and commissioning of 100/5 Amps, test resin cast tap wound current transformer of rating 100/5 Amps on LT panel board and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable ( FRLS ) complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable current transformers of 250/5 CT ratio of any description and supply, fixing, connecting, testing and commissioning of 250/5 Amps, test resin cast tap wound current transformer of rating 250/5 on LT panel board and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable ( FRLS ) complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable current transformers of 400/5 amps ratio of any description and supply, fixing, connecting, testing and commissioning of 400/5 Amps, test resin cast tap wound current transformer of rating 400/5 Amps on LT panel board and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable ( FRLS ) complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable indication lamps and supply, fixing, connecting, testing and commissioning of indication lamps LED type with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable ( FRLS ) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement including necessary connection and commissioning of the following fittings / fixtures/accessories in the existing panel board/feeder pillar box including testing complete all as specified and directed by Engineer-in-Charge.
(b) Aluminium bus bars of any shape and size .
(c) Copper bus bars of any shape and size .
(d) Conical/ single bus bar system epoxy insulator including nuts, bolts and washers suitable for LT 415 Volts, 50 Hz AC supply for mounting of bus bars in LT panels/feeder pillar boxes complete
Supply,fabrication & fixing of doors of LT panel /AMF panel/HT bus bar panel both front /back side made out of GI sheet 2.0 mm to 3.15 mm thick complete with hinges including welding to panel body and locking system, complete including two coat of synthetic enamel paint by spray machine over a coat of red oxide primer all as specified and directed by Engineer-in-Charge.
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (As per existing colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable including taking out existing cable protection cover etc. complete all as specified and directed. Note :- Excavation shall be carried out manually all as directed.
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand cushioning for XLPE cable with tibba sand (one layer of 80 mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable) & punning down to 180 mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- Punned thickness only shall be measured and paid.
Material & labour for stone slab 40 mm to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Labour only for laying of stone slab 40 to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 cm wide and thickness not less than 50 mm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning complete all as specified and as directed.
Supply, Laying, jointing and testing in replacement of XLPE LT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-
a) LT aluminium conductor cable of size 16 Sqmm, 4 core
b) LT aluminium conductor cable of size 25 Sqmm, 4 core
c) LT aluminium conductor cable of size 35 Sqmm, 3 ½ core
d) LT aluminium conductor cable of size 50 Sqmm, 3 ½ core
e) LT aluminium conductor cable of size 70 Sqmm , 3 ½ core
f) LT aluminium conductor cable of size 95 Sqmm , 3 ½ core
g) LT aluminium conductor cable of size 120 Sqmm , 3 ½ core
h) LT aluminium conductor cable of size 185 Sqmm , 3 ½ core
Disconnecting & taking down old existing unserviceable MCCB of any description and in any position complete all as specified and directed by Engineer-in-Charge.
S&F MCCB, 400 Amps, four pole, 36 KA, 415 volt with adjustable type release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
S&F MCCB, 250 Amps, four pole, 36 KA, 415 volt with adjustable type release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
S&F MCCB, 200 Amps, four pole, 36 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
S&F MCCB, 160 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
S&F MCCB, 100 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
S&F MCCB, 63 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and commen salt. PCC (1: 3 : 6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 12 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe light grade for watering and 40mm dia light earth lead protection pipe upto 7.5 m complete all as specified and directed.
Supplying and fixing in repair earth continuity conductor or main earthing lead 32mm x 6mm, GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers and saddling ,welding at every joint complete all as specified & directed
M&L Boring of horizontal holes under road pavement, hardstanding by trenchless technology using boring machine including the HDPE protection pipe of 100 mm bore all as directed as per Engineer-in- Charge.
Supply, install, testing and commissioning in repairs on load change over switch 100 Amps, four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in repairs on load change over switch 125 Amps , four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in repairs on load change over switch 200 Amps , four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in repairs on load change over switch 320 Amps , four pole, 415V AC ,50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in repairs on load change over switch 400 Amps, four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge.
M&L for plain cement concrete PCC1:3:6, type C-2 (Using 40mm graded stone aggregate) for pole coping/foundation of panel/ hard standing complete all as specified and directed by Engineer-in-Charge.
S&F in repair aluminium cable lugs of size 10 sq mm to 25 sq mm complete all as specified and directed.
S&F in repair aluminium cable lugs of size 25 sq mm to 50 sq mm complete all as specified and directed.
S&F in repair aluminium cable lugs of size 70 sq mm to 150 sq mm complete all as specified and directed.
S&F in repair aluminium cable lugs of size 185 sq mm to 240 sq mm complete all as specified and directed.
S&F in repair aluminium cable lugs of size 240 sq mm to 400 sq mm complete all as specified and directed.
S&F in repair aluminium cable lugs of size 500 sq mm to 630 sq mm complete all as specified and directed.
M&L in repair for stay assembly complete with accessories as shown in electric plate No.1 including loop type insulator, stay clamps, stay wire, PCC and excavation etc with diameter of stay 20 mm of stay rod complete all as specified & directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 25 sq mm to 50 sqmm complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 95 sq mm complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 120 sqmm to 150 sq mm complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 400 sq mm complete all as specified and directed.
S&F in replacement GI tubing light grade 80 mm dia for pole cable protection including fixing clamp, nut bolt washer complete accssories etc complete all as specified and directed.
S&F in replacement GI tubing light grade 50 mm dia for pole cable protection including fixing clamp, nut bolt washer complete accssories etc complete all as specified and directed.
S&F in replacment of out door type LT Feeder Pillar box (Kiosk) of size not less than (L) 60 cm x (W) 45 cm x (H) 45cm made out of 3.0 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement, with and inluding Copper Busbar 400 amps rating and one MCCB 250 Amps, 04 pole, 25 KA thermal magnetic release type for incoming and fixed on angle iron 40x40x6mm frame of suitable size and embedded in PCC plinth 45x45x60mm made of PCC 1:4:8 type D-1 using 40 mm graded stone aggregate complete all as specified and directed by the Engr-in-Charge.
Nvimal Engineers and Contractor
M/s R K Enterprises
new india engineers
Achal Sales
LOKESH ELECTRICAL WORKS CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .