Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 3 333 F M P ARCS VENGACHUVADU VAZHAKKULAM P O CHAITHANYA BUILDING SA ROAD KADAVATHRA MUVATTUPUZHA ERNAKULAM 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.2 L+₹1.5 L (3.73%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹74.7 L+₹35.0 L (88.1%)Rejected-AOC | L3 | Rejected-AOC L3 REJECTED |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
23 Dec 2022, 5:00 pmClosed
MANAGING DIRECTOR
SILK FOUNDRY UNIT Ottapalam, Palakkad Kerala - 679103
Standardization of existing electrical installation, additions in HT Panel, Installation of 866 kVA Furnace transformer and MV additions at SILK Foundry Unit, Ottapalam, Palakkad, Kerala
2022_SILK_537322_1
SILK-FUO/CP/24C
Open Tender
Miscellaneous Works
Item Rate
90 days
Ottapalam
As per the tender documents
10 documents required · 10 mandatory
₹2,950
₹50,000
Yes
3 Feb 2023
7 Dec 2022
24 Dec 2022
7 Dec 2022
23 Dec 2022
7 Dec 2022
7 Dec 2022 - 23 Dec 2022
Amount
Supply and installation 866kVA 11kV/ 2 x 290 V Delta star Secondary with 6 Phase Ddy0 11 Vector group.
od106394/2022_2023 : Installation in the existing foundation and Testing at site Oil cooled indoor type 11kV/(290V) 6 Phase converter type Furnuce application Transformer with Minmum 866 kVA capacity with Onload tap changer (OLTC) and remote control operation, Protectioon and monitoring system as per State Electrical inspectrate norms .
Supply and installation of HT Panel
od106459/2022_2023 : Installation of HT panel consisting of Indoor One number 11kV, 630A, 350MVA indoor VCB Panel with CT,PT, relay, Meters as Incomer and Three number 11kV, 630A, 350MVA indoor VCB Panel with CT, relay, meters as outgoings with Aluminium bus bar mentioned in ANNEXURE 1 (Bill of Materials 4 panel) Indoor One number 11kV, 630A, 350MVA indoor VCB Panel with CT,PT, relay Meters as Incomer with KSEB metering cubicle with 3no Class 0.2S CT,1No (suitable for 1100kVA contract demand) three phase class 0.2PT with provision for 11KV ABT meter with Aluminium bus bar mentioned in ANNEXURE 2 (Bill of Materials 1panel + Provision for ABT Meter)
Panel
od106469/2022_2023 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure 8 Way 4 Pole MCCB Incomer and 4 Pole MCCB Out Going Double Door Load bank ( Power Safe Panel) suitable for 100A MCCB as incomer Panel including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing 4P 100 A 18kA MCCB with suitable spreaders as incomer and 16A/20A/32A/40A/50A/ 63A 4 Pole (FP) MCCB as outgoing. with suitable spreaders Meter Module with digital multi function meter (V, A, F, KWHr), 100/5 Class 1 resin cast CT's 3 Nos LED Indicators, control MCBs and corner box on both side at the top, Add on module of the same size of the panel at the bottom and 2 nose of cable alleys in both sides complete. fixed on wall / MS Frame work using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way double cover (L & T make Enersys / Havells Load line or equivalent ready made sub board)
od106592/2022_2023 : Providing anf fixing 32-63A Four pole MCCB with spreader set.
od106593/2022_2023 : Providing and fixing 20-50A Triple MCCB with spreader set.
od106594/2022_2023 : Providing and fixing 25A Double MCCB with spreader set .
od106595/2022_2023 : Providing and fixing 25A Single Pole MCCB with spreader set as out going.
od106596/2022_2023 : Providing and fixing 125A 4 pole 15kA MCCB with spreader set as Incomer.
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Industrial Light Fittings
od107396/2022_2023 : Supply and Installing on Truss WELL GLASS LED Fitting 70 Watts 130 lm/W 140 -270 V AC input range 6kV in build Surge protection 50k Burning Hrs @ L70 B50 standards 340mm Dia THD <10% 5700K Colour Temp (CCT) 60 Degree lenses IP 66 and IK 08 compatible Panasonic
od107397/2022_2023 : Industrial Batten IP 20 LED batten for surface and suspended application. White powder coated CRCA housing with LEDs. Seamless front frame is with white high transmission acrylic cover and decorative end cap. 20 W 5700 K (CCT) Panasonic Make HARROW Model No PBTM12208 or equivalent.
od107398/2022_2023 : Supply and Installing on Truss Bay Light Fitting LED Circular 180 Watts 150 lm/W UV Stabilized IP PC Lens, 140 -270 V AC input range 4kV in build Surge protection 50k Burning Hrs @ L70 B50 standards 340mm Dia THD <10% 5700K Colour Temp (CCT) 60 Degree lenses IP 66 and IK 07 compatible Panasonic Make ENVISO PRO PBYM14KL8 or equivalent.
Transformer to Furnace Panel
3.13.7 : Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required1600 amps 50 KA SC for 1 sec
MS Powder Coated Cable Tray with Cover
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.5 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.1.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
4.2.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required100 mm width X 50 mm depth X 1.6 mm thickness
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness
4.2.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required225 mm width X 50 mm depth X 1.6 mm thickness
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness
4.2.5 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required375 mm width X 50 mm depth X 2.0 mm thickness
4.2.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required450 mm width X 50 mm depth X 2.0 mm thickness
4.3.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.3.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.4.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.4.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.4.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.4.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.5.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.5.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.5.5 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.5.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Cable Laying & Termination
od107855/2022_2023 : Supplying and making indoor cable end jointing with Heat shrinkable Kit , including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required: 300 Sq mm HT Cable End Termination indoor HT panel and Transformer
od153502/2022_2023 : Supplying and making end termination with Double compression whether proof Cable gland and Heavy duty aluminium lugs and Earth Tag of suitable size for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Semi open environment.Above 63 mm size Double compression Gland size
od153503/2022_2023 : Supplying and making end termination with Double compression whether proof Cable gland and Heavy duty aluminium lugs and Earth Tag of suitable size for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Semi open environment.Up to and Including 50 mm size Double compression Gland size
od153504/2022_2023 : Supplying and making end termination with Double compression whether proof Cable gland and Heavy duty aluminium lugs and Earth Tag of suitable size for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Semi open environment.Up to and Including 40mm size Double compression Gland size
od153505/2022_2023 : Supplying and making end termination with Double compression whether proof Cable gland and Heavy duty aluminium lugs and Earth Tag of suitable size for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Semi open environment.Up to and Including 32 mm size Double compression Gland size
od153506/2022_2023 : Supplying and making end termination with Double compression whether proof Cable gland and Heavy duty aluminium lugs and Earth Tag of suitable size for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Semi open environment.Upto and including 19mm Size Double compression Gland size.
7.3.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
7.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 35 sq. mm and upto 95 sq. mm
7.3.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 95 sq. mm and upto 185 sq. mm
7.3.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 185 sq. mm and upto 400 sq. mm
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
od157631/2022_2023 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 33 KV<br>grade of following size on cable tray as required.<br>Above 185 sq. mm and upto 400 sq. mm
od127514/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988. 3.5core 50 sq mm armoured aluminium
od127515/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.4 core 16 sq mm armoured aluminium
od127516/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.4 core 10 sq mm armoured aluminium
90.12.2.42 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
od127517/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.4 core 6 sq mm armoured aluminium
od127887/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.3.5 core 150 sq mm armoured aluminium
od127888/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.3.5 core 95 sq mm armoured aluminium
od127889/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988.3.5 core 35 sq mm armoured aluminium
od128260/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988. 3.5core 400 sq mm armoured aluminium
od128261/2022_2023 : Supply at site Power Cables, Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour(Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanised wire for cables up to 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed,650V grade as per IS 7098(Part 1) 1988. 3.5core 240 sq mm armoured aluminium
od128412/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.1.5 sq mm 2 core armoured copper control cable
od128450/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.1.5 sq mm 4 core armoured copper control cable.1.5 sq mm 3 core armoured copper control cable
od128451/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.1.5 sq mm 4 core armoured copper control cable
od128452/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.2.5 sq mm 3 core armoured copper control and Light cable.2.5 sq mm 2 core armoured copper control cable
od128453/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.2.5 sq mm 3 core armoured copper control and Light cable
od128454/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.2.5 sq mm 4 core armoured copper control and Light cable
od128455/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.2.5 sq mm 5 core armoured copper Power cable
od128456/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.4 sq mm 5 core Un armoured copper Power cable
od128457/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.4 sq mm 10 core Un armoured copper Power cable
od128458/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.6 sq mm 5 core Un armoured copper Power cable
od128459/2022_2023 : Supply at site Power and Control Copper Cables, Solid Copper conductor,XLPE Insulated, cores laid up, PVC tape innersheathed,Unarmoured/Armour (Galvanised wire for cables up to 14 x 1.5 sqmm, 9 x 2.5 sqmm, 2x16 sqmm, 3x10 sqmm,4x10 sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988.10 sq mm 5 core Un armoured copper Power cable
od157689/2022_2023 : Supply of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 3.3 KV grade of the following sizes making good the damages , colour washing etc. as required.<br>3 core 300 sq mm
14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.2 : Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
Walk way electrical works
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
14.16.1 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
14.16.2 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.16.3 : 120 mm dia (OD-120 mm & ID-103 mm nominal)
14.16.4 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)
od117206/2022_2023 : Supply of suitable size Polyamide flexible conduit with IP67 End coupling fixed using Polyamide Bracket having 105 Degree Celsius Temperature as per UL 94V0 Protection for exposed cables.
Walk way civil works
od119207/2022_2023 : Supply and Providing FRP walk ways up to 12 Mts height truss purling of existing space frame Industrial shed construction. All light cables fittings and Bus Trunking shall be accessible from the walk way the width of the wake way shall be 45 cms with 2 side Z purling using Hot dipped GI Z sections having minimum 2 mm thickness to accommodate 2 labours working capacity. Including Providing FRP Bracket below the walk way to accommodate Well Glass fitting up to 4KG weight as per lighting layout plan
od119208/2022_2023 : Supply and providing FRP Indoor Transformer fencing using 46 x 46 mm FRP pillars in every 1.2 mts span FRP grills with 100 x 100 mm Mesh gap at a height of 1.8 Mts including 2 Nos SS hinged doors with lockable mechanism on top of 60 cms Solid concrete block curb wall as directed by the Engineer in charge
od119209/2022_2023 : Supply and providing wall supporting type fixed FRP ladders to access the walk way from plant 6 Nos<br>
MSB, SSB and Motor control centres, (Additional works attached to the existing enclosure, factory built assemblies as per site requirements. )
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
od119683/2022_2023 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure 8 Way TP Motor Control Centre (MCC1) Provision to install 80 A 4P MCCB as Incomer and Out Going 3 Pole MPCB ICU 100kA Rotary type with suitable spreaders + 13 A Power Contactor having coil voltage of 220V including copper /brass bus bar, earth bus and DIN rail with 2 NO 2 NC for remote operation and indication suitable for Up to 5 HP inductive load having coil voltage of 220V including copper /brass bus bar, earth bus and DIN rail Meter Module with digital multi function meter (V, A, F, Whir), 100/5 Class 1 resin cast CT's 3 Nos LED Indicators, control MCBs with factory made copper bus bar links the fabrication of panel should be suitable for wall mounting in nature and should comply form 4 defined by IEC 61439 - 2.
od119684/2022_2023 : Supply Fabricate and erect 100 x 50 mm ISMC Base frame with 8 mm tapped/ Client rivet hole to accommodate panels and 6 nose 16mm holes to mound the panel to ground as required duly painted using anti rust rubber based black paint. Over 2 coat of zincromate base coat or using epoxy any rust coating on base frame.
od119685/2022_2023 : Supply Fabricate and erect 35 x 35x 6 mm ISLA Wall frame with 8 mm tapped/ Client rivet hole to accommodate SMDB/MCBDB/VDB/ MCC/PBS/ Starter Panel panels and 6 nose 16mm holes to mound the panel to ground as required duly painted using anti rust rubber based black paint. Over 2 coat of zincromate base coat or using epoxy any rust coating on base frame.
od119686/2022_2023 : Supply and providing suitable sized SS 202/GI/ Brass bolt nut washers hardware as required
Earthing and Miscellaneous Works
od120044/2022_2023 : Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with Lockable GI /CI Manhole cover plate 600 x 600 Heavy duty having locking arrangement and watering pipe of 2.0 metre long etc. (but without charcoal/ coke and salt ) as required.
od120046/2022_2023 : Supply and providing Back fill using Electrafill (Carbon Based) Earth Enhancing Compound conductive material which improves earthing effectiveness, especially in areas of poor conductivity (rocky ground, areas of moisture variation, sandy soils etc.) by enhancing its absorption power and increasing its richness with charge carrying ions. as per RoHS (TC No: (8714)337-0050), TCLP (TC No: CGR0000898925) Tested and certified
od120049/2022_2023 : Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
od120050/2022_2023 : Providing and fixing 40 mm X 4 mm Nical Sealed Copper Bonded Earthing Strips 250 microns copper Bonded on surface or in recess for connections etc. as required.
od120051/2022_2023 : Providing and fixing 50 mm X 5 mm copper Bonded strip (250 micron)on surface or in recess for connections etc. as required.
od154425/2022_2023 : Supply and Changing roof sheet for MSB room 0.45 mm TATA/JSW colour coated Tripode sheet roof laying sheet using self taped SS/Aluminum Alloy Hex head screws with rubber gasket as required.
od154426/2022_2023 : Supply and providing Heat shrinkable sleeves up to 40 x 4mm earth conductors Green colour. Duly inserted in the exposed earth strips.
od154454/2022_2023 : Supply and providing wall cladding and inner separation using wall cladding sheet switched 0.35 x 035 with 12 mm PUF insulation TATA/JSW colour coated Tripode sheet roof laying sheet using self taped SS/Aluminum Alloy Hex head screws with rubber gasket as required.
od154455/2022_2023 : Supply and providing Heat shrinkable sleeves for 50 x 6 mm earth conductors Yellow Green striped colour. Duly inserted in the exposed earth strips.
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.18.3 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair
14.7 : Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
14.14.4 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
14.15.2 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.15.3 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
Repair Works
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
od139837/2022_2023 : Supply and providing Multy function meters with Power and Energy parameters with suitable class 1 CT energy management Panel wise with communication port . L&T MFM4405 LED with RS485 communication or similar reputed make Schnider/Risheb/Socomec
od139838/2022_2023 : Supply providing, fixing interconnection links and earth connections Medium voltage arrester 15 10 1 L Medium voltage arrester without shield for protection of transformers,switching systems and transmission lines against atmospheric and switching surges according to IEC 99-4 / EN 60099-4 High temperature vulcanised (HTV), hydrophobic silicon enclosure Pregreg sheet High bending resistance Unbreakable at overloads Rated voltage: Ur = 15 kV Continuous operating voltage: Uc = 12.0 kV Nominal discharge current: In = 10 kA (8/20) Line discharge class: 1 Rated frequency: (15 - 62) Hz Ambient temperature: (-40 - +55) °C Design: indoor Creepage distance: 138 mm HTV-silicon enclosure h = 162 mm; RAL 3013 Supply and mount Brand: DEHN Type: DMI 15 10 1 L Part No.: 990005 or equivalent.
od139839/2022_2023 : Supply and providing Impulse meter IZ 100 Impulse meter with counter for registration of discharge currents Quick data acquisition Corrosion resistant Min. count current: 100 A (8/20) Max. high current withstand capability:100 kA (4/10) Terminal bolt: M12 Aluminium enclosure: IP 67; grey Supply and mount Brand: DEHN Type: IZ 100 Part No.: 994001 or equivalent.
od139840/2022_2023 : Supply providing, fixing interconnection links and earth connections type 1 SPD in the MSB as per BS EN/IEC 60305 Dehn Part No 952320 – DEHN guard M DG M TT 320 Type 2 Surge Arrester (3Ph+1N Circuit) or equivalent.
od139841/2022_2023 : Supply providing, fixing interconnection links and earth connections type 1 + 2 (T1 +T2) SPD in the MSB as per BS EN/IEC 60305 Dehn Part No 900360 DEHNVAP CSP DVA CSP 3P 100FM having Uc 255 V In 100 kA Up1.5kV SPD NPE or equivalent.
od139938/2022_2023 : Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with Electrical Inspectorate Department and avail KSEB service connection application form and submitting to the consumer for up grading HT Contract demand up to 1100 kVA Three phase service connection/Load regularization and Additional CD etc (Actual amount paid on production of Original bill/ Invoice or demand letter from KSEB department)
od154673/2022_2023 : A3 Drawing for scheme to Electrical inspectorate as fitted
od154674/2022_2023 : 2mm Electrical garage rubber mat
od154675/2022_2023 : 12.5 HP FASD State panel with out enclosure (Enclosure will be measured separately as per item No 25.1)but with base plate and control fuses. MN type AC 3 Duty coil voltage 415 V Relay 14-23, with illuminated push button station on aluminium dia cast post button station housing with IP 67 mounted and wired on motor control gear box fabricated out of 16 gauge CRCA sheet steel duly powder coated with handed door and neoprene beading as directed by Engineer in charge.
od154772/2022_2023 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
od154773/2022_2023 : Smart demand controller with class 0.5 CT -/1 or -/5 and communication protocol as per EN 50160, 61000-2-4 watchdog RCM report and power Quality Report including gateway for 1 year rental charges With alarm and status indication display. Janitza UMG 512 –PRO or similar reputed Class A device as per EN 61000-4-30. or similar reputed make GFUVE/BENDER/MEGGER
od139838/2022_2023 : Supply and providing Multy function meters LCD display with Power and Energy parameters including THD and K Factor up to 31st Harmonies with suitable class 1 CT for energy management in Transformers LT side with communication port RS 485 and gateway for monitoring remotely. L&T MFM4430 LCD with RS 485 or similar reputed make of Schnider/Risheb/Socomec
Supply & Providing Electrical accessories for MV Panel Boards
od154118/2022_2023 : 80A 4P 16kA MCCB with spreader set as Incomer Conforms IS/IEC 60947-2, IEC 60947-2 & EN 60947-2
od154119/2022_2023 : 16A MOG-H1M Rotary Type Thermal Release range 1.6-2.5A ICU 100kA
od154120/2022_2023 : Auxiliary and Alarm left side mounding
od154121/2022_2023 : DOL starter Link up to 13A
od154122/2022_2023 : AC3 Rating 13 A Power contactor with 230 V coil voltage IS / IEC 60947-4-1 & IEC 60947-4-1
od154123/2022_2023 : ON / OFF Push button station with illuminated push button on dia cast aluminum enclosure IP54
od154124/2022_2023 : 8 mm Metal body R/Y/B and G Led Indication lamp with in line glass control fuse
od154125/2022_2023 : Protective relays as per Electrical Inspectorate requirements MC12 A with 5 P10 CT
Civil Works
26.77.1 : Erection & Installation of Precast/Prestressed Concrete elements in correct & final position with proper line level and plumb at site making all arrangements (i.e cranes, push-pull jacks & all another T & P for lifting Placing & Alignment of elements, within erection tolerance as per IS 15916 as per approved shop drawings and all complete as per the direction of Engineer-in Charge but excluding the cost of sim pads, non shrink grout and steel works i.e hangers. All work up to fifth floor.Prestressed hollow core Slab up to 200 mm thickness
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
14.1 Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.15.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal
od Supply and unloading at site. Pre cast U drain of 1 m depth 100 mm wall thickness for laying HT cable with cover slab having load bearing capacity of 20 MT including back filling on side and make the area good as required RCC M 40 grade 2 meter long at road crossing area as per IS: 10297/1982
Standardization Works on existing Installation
Dismantling Sub panels from existing control room shifting placing re errection floor mounting panels to proposed control room at Plant re arranging feeder cables as required.
Retrieval of existing cables from SSB to Starter panels re arranging to MCC and SMDB including re glanding end termination after re installation of panels as required.
Dismantling MCC from the plant re locating to proposed control room cable re arrangement termination and eathing using dismantled materials .
Labour charges for Re arranging existing LT cables to Existing Induction Furness and control panel using Cable supports /Cable tray as required.
Supply and providing LT side of MV/SSB Panel cables end re termination using new cable lugs as required .
Earthing and re termination of Motors Panels starter Box Gland earthing Push button stations MCB DB 's as per Inspectorate requirements ( Earth Copper and SS Hardware will be measured separately).
Providing cable protection, PUF sealing to entry holes plastering and minor repair works associated with the alteration and re arrangement.
DIXON PAUL K
HELSA ELECTRICALS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .