GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
COMPREHENSIVE MAINT AND REPAIR OF AC PLANTS DG SETS CONTROL PANELS LIGHT AND PANEL AT CQA (I) AREA UNDER GE (I) RND DEHRADUN
2022_MES_540818_1
GE(I)RND/9153/E8/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEAL DEHRADUN
Class E Category c (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹46,000
Yes
14 Sept 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
22 Aug 2022
8 Aug 2022
25 Jul 2022 - 8 Aug 2022
Amount
Disconnecting, dismantling of air cooled Packaged type AC Plant 16.5 TR capacity complete with indoor and out door unit, strip opening, cleaning & descaling complete with dust cleaning equipment and servicing of the AC plant with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective minor parts & wiring , painting the bottom with one coat of black synthetic enameled paint of out-door unit, replacement of air filters, belt and replacement of the unserviceable and defective minor parts, heater, brazing, reassembling and testing of the AC plant complete all as specified and directed. NOTE :- (i) The defective/nonfunctional minor parts will be replaced by the contractor under the unit rate quoted for this item. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 1 complete,all as specified and directed. Make: Servo froze -68-10c of IOC.
Supply fixing and testing in replacement of UNSV liqude line filtter driers of suitable size for Package type AC plant 16.5TR complete all as specified & directed.
Supply and fixing/testing in replacement of UNSV V belt 'A' type as per existing for blower fan of packege type unit complete, all as specified and directed.
Supply and fixing/testing in replacement of UNSV compressore 5.5 tr make denfoss/copland scroll compressore R-407 with pressure testing complete, all as specified and directed.
Disconnecting & taking out existing defective blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts strip opening for rewinding, removing for rewinding to & from to workshop, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) including suitable bearing, insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation & fixing the motor at site including necessary connecting & testing at site complete all as specified and directed.
Supply and fixing/testing in replacement of UNSV blower motor Package type AC Plant of any description & in any position of size 2/3 HP, 415 volts suitable for package type plant 16.5 TR
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Package type AC 16.5 TR three phase capacity complete all as specified and directed . (Make : Carrier/Hitachi/LG )
M&L for replacement of unserviceable condensing coil unit for Package type AC of any type/ any capacity complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply, fixing, connecting and testing in replacement of UNSV thermostate heating/cooling of any description complete,all as specified and directed.
Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any position complete, all as specified and directed.
Supply fixing and testing in replacement of UNSV Pre filter with GI sheet frame of size 1000mm x 500mm x 8mm deep suitable for Pakage type units of air conditioning plants including efficiency 90% , down to 10-20microns, Initial Pressure drop- 2.5 mm WG, filter media shall be Synthetic Non Woven with Both Side HDPE Mesh, and t testing complete complete, all as specified and directed.
Dismantling & opening of GI sheet ducting from AHU for cleaning & descaling complete with air compressor, vacuum cleaning unit, dust cleaning equipment. The cleaning of duct to be started from AHU to different brances in different room. All the grills and diffusers are to be cleaned befor re-fixing. The rate shall also include cost of dismantling of false ceiling and its refixing, repair leakage ducts and refixing of ducts after complete cleaning process and testing etc. complete all as specified and directed. Note :- (i) Old disturbed insulation / leackage of ducts shall be made good by the contractor.
Supply fixing,connecting and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 16 Amps. Complete all as specified and directed .Make L&T or equievelent model of specified and directed.
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 50 Amps. Complete all as specified and directed . Make L&T or equievelent model of specified and directed. .
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 70 Amps. Complete all as specified and directed . Make L&T or equievelent model of specified & directed
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Volt meter 0- 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Amp meter 0- 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
Supply fixing and testing in replacement of UNSV indicator light red/yellow /green complete in the existing panel Complete connecting electrically all as specified and directed
Supply, fixing, connecting and testing in replacement of UNSV MCB four pole, 100 Amps 415 volts, 50 Hz having breaking capacity 10 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete all as specified and directed. Make : L&T /INDO ASIAN/Havells
Supply, fixing, connecting and testing in replacement of UNSV MCCB four pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells
Dismantling and opening of spare parts for servicing of water cooled DG set of 75 KVA to 100 KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,i.e diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil/distilled water etc as required at site and as per manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction complete all as specified and directed. (including mentioned in Note here in below) Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item No 23 to 26, 32 & 33 of Sch `A’ as supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under appropriate item of Sch ‘A’ . Its cost of filling is deemed to be included under the rates quoted by the contractor for above item.
Supply only element diesel filter with gasket suitable for 75 KVA to 100 KVA, 3 phase 50 HZ, capacity of DG set dismantled / fixed under Sch `A` item No 1.00 here in above complete all as specified and directed. Make: CUMMINS/Kirloskar
Supply only element Oil filter with gasket suitable for 75 KVA to 100 KVA, 3 phase 50 HZ, capacity of DG set dismantled/fixed under Sch `A`item No 1.00 here in above complete all as specified and directed. Make: CUMMINS/Kirloskar
Supply only Air cleaner element primary and safety for 75 KVA to 100 KVA, 3 phase 50 HZ, capacity of DG set dismantled/fixed under Sch `A` item No 1.00 here in above complete all as specified and directed. Make: CUMMINS/Kirloskar
Supply only element bypass filter with gasket for 100 KVA capacity DG Set dismantled/fixed under Sch `A` item No 22.00 here in above complete all as specified and directed.
Suply,installation,testing and commissioning in replacement of unserviceable AVR unit suitable for 3 phase 50 HZ alternator suitable for 75 KVA to 100 KVA KVA capacity of DG set complete all as specified and directed.
Dismantling and taking out the radiator fitted in 75 KVA to 100 KVA, 3 phase 50 HZ, capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution, including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks. including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator, re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item 29 to 31 of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. Make: CUMMINS/Kirloskar
Supply only Radiator hose set with clamp complete set for 75 KVA to 100 KVA 3 phase 50 Hz DG Set.
Supply only Water pump assembly complete set for 75 KVA to 100 KVA, 3 phase 50 Hz DG set
Supply only concentrated coolent suitable for radiator of DG set any capacity drained out / filling under Sch `A`item No 28 here in above complete all as specified and directed.
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) suitable for Engine of DG set any capacity drained out / filling under Sch `A` item No 22 here in above complete all as specified and directed.
Supply only distilled water Complete, all as specified and directed by Engr-in-Charge,
Dismantling and taking out the PT fuel system including injectors assembly fitted in 75 KVA to 100 KVA 3 phase 50 HZ, capacity of DG sets 3 phase 50 HZ of DG set and strip opening of PT fuel system including injectors assembly for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and calibration of Fuel Injection after repair/ servicing /overhauling and re-assembling and fixing the same in position and testing complete all as specified and directed . Notes :- (i) Repairs/servicing / reassembling and testing of Fuel injector pump shall be carried out through a authorised service center on testing machine. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item No 35 to 50 of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre. Make: CUMMINS/Kirloskar
Supply only Kit injector barrel plunger
Supply only Kit Gasket Governor set
Supply only Ball Bearing
Supply only Gasket fuel pump .
Supply only Screen filter .
Supply only Ball check .
Supply only Gasket Injector .
Supply only Seal ‘O’ ring .
Supply only Pump gear fuel .
Supply only Shaft fuel pump drive .
Supply only Shaft tachometer drive .
Supply only Bushing tachometer drive.
Supply only Plunger governor .
Supply only Supply only Plug injector orifice.
Supply only Seal dust.
Supply only Kit seal .
Supply , fixing, connecting and testing in replacement of following unserviceable spare parts of suitable for DG set of 75 KVA to100 KVA capacity,3phase,50HZ complete all as specified and directed.
Seal key way.
Water separator .
Oil temperature gauge.
Water temperature gauge.
Oil pressure gauge 0 to 7 kg/cm2 .
Hours meter.
Hump hose & bend
Toggle switch
Elbow male union.
Dust cap.
Ignition switch along with duplicate keys.
Switch Temp .
Switch pressure .
Diaphram Pulley
Shut Down Valve
Hose fuel suction suitable for 75 KVA to 100 KVA DG set.
Hose fuel Return suitable for 75 KVA to 100 KVA DG set.
Hose Fuel, Water sperator to filter suitable for 75 KVA to 100 KVA DG set.
Hose Fuel, Filter to Fuel pump suitable for 75 KVA to 100 KVA DG set.
Dismantling and taking out the self starter,12 Volt DC fitted in 75 KVA 3 phase 50 HZ of DG sets and strip opening of Self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling of Self starter 12 Volt DC after repair/ servicing /overhauling and fixing the same in position and testing complete all as specified and directed . Notes :- (i) Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service center . (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item No 53 to 58 of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Solenoid switch suitable for self starter, 12 Volt DC
Commutator suitable for self starter, 12 Volt DC
Carbon brush suitable for self starter, 12 Volt DC
Field coils suitable for self starter, 12 Volt DC
Bendix pinion assembly suitable for self starter, 12 Volt DC
Bushe suitable for self starter, 12 Volt DC
Dismantling and taking out the self starter, 24 Volt DC fitted in 100 KVA 3 phase 50 HZ of DG sets and strip opening of Self starter 24 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling of Self starter 24 Volt DC after repair/ servicing /overhauling and fixing the same in position and testing complete all as specified and directed . Notes :- (i) Repairs/servicing / reassembling and testing of Self starter 24 Volt DC shall be carried out through a authorised service center . (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item No 60 to 65 of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Solenoid switch suitable for self starter,24 Volt DC
Commutator suitable for self starter, 24 Volt DC
Carbon brush suitable for self starter, 24 Volt DC
Field coils suitable for self starter, 24 Volt DC
Bendix pinion assembly suitable for self starter, 24 Volt DC
Bushe suitable for self starter, 24 Volt DC
Disconnecting existing non functional armature of self starter, 24 Volt DC fitted in 100 to 285 KVA DG set , dismantling and strip opening of the armature of self starter, 24 Volt DC, removing the old existing burnt windings, cleaning the slots & rewinding of the armature of self starter, 24 Volt DC, including supply with existing gauge super enameled copper conductor , including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc as required at workshop and transportation to site & refixing on same position & testing complete all as specified and directed .
Dismantling of Old unserviceable batteries 12 Volt, 180 AH, from DG set and supply & fixing maintenance free batteries of 12 Volt, 180 AH capacity with electrolyte fully charged battery including interconnection, commissioning and testing complete all as specified & directed.
Disconnecting and taking out the exhaust system of DG set of any capacity between 75 KVA to 100 KVA and carrying out cleaning of choked, carbonized exhaust pipe including exhaust silencer , including soldering / welding of leakage of pipe.and assembling the complete exhaust assembly including replacement of exhaust manifold gasket side pieces, metallic flexible pipe, nut bolts, and testing for making it leak proof and fixing the same in position and testing the system complete all as specified and directed complete all as specified and directed.
M & L for Cleaning of MS fuel tank of DG sets of 100 to 300 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Disconnecting and taking out old unserviceable belts of the DG set and supply and fixing new belt suitable for following capacity of DG set engine match the existing complete all as specified and directed.
V Belt for Fan drive ,Charging alternator and water pum complete set suitable for DG Set 75 to 100 KVA
Disconnecting and taking out engine fitted in 75 KVA to 100 KVA 3 phase 50 Hz of DG set ( Make: Cummins/Caterpillar/Kirloskar/ Greaves) , dismantling and strip opening of complete engine of water cooled DG set of suitable capacity 3 phase 50 Hz for carrying out repair and complete over hauling , mechanically and electrically, cleaning,oiling/greasing , and fixing of serviceable parts in position, and removing & replacement of unserviceable/ defective parts /spares with new parts,as per manufacturer's instructions cleaning , oiling /greasing,descaling of water jackets,decarbonizing cylinder heads including refacing and lapping of valves, valve-seats, grinding of crank shaft or any other machining work required at site, allingment of connecting rods including matching with crank shaft. and reassembling the engine of DG set at position ensuring proper alignment and coupling the engine with alternator, complete all as specified and directed. (including mentioned Note in here in below). Notes for Sch A item No. 72 here in above : (i) Repairs/Overhauling / reassembling and testing of engine of DG set shall be carried out through a authorised service center . (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under item No 73 to 91 of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of loading, unloading & transportation to and fro authorized service centre and machining job etc.as required (iv) The element for connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge shall be included/covered under the rates quoted in Sch A item No.72 here in above consider for Maintenance and servicing.
Liner cylinder
Piston
Pin Piston
Ring Snap
Gasket cylider head (Front)
Gasket cylider head (Rear)
Gasket cylider head Cover
Valve Intake (ALTV)
Valve Exhaust (ALTV)
Guide Valve
Seal valve steam
Cotter valve
Bearing con rod
Bearing Main
Overhaulling Gasket Packing kit full
Valve seat
Valve Sprng
Spring cup
Oil Pump
Chemical Earthing with copper pipe electrode 3.0 M long having outer pipe dia 50mm & inner pipe dia 44mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical compostion Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with Copper earth strip 20x3mm upto 7 meter length, making PCC pit of size 0.3mx0.3mx0.3m (inner size) in mix 1:3:6 type CI with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 8mm dia bar and testing on completion to acheive value not more than 0.5 ohm complete all as specified and directed.
M&L in replacement of eathing continuity conductor to wall on batten or buried in ground or drawn in conduit or fixed to pole or any other indicated situation for loop earthing etc, as required 20x3 mm dia copper strip, all as specified and directed.
Supply, fixing, connecting and testing in replacemnt of UNSV turbo charger service kit suitable for 75 to 100 KVA 3 phase 50 HZ capacity of DG sets as per existing shape and size complete all as specified and directed.
Supply and replace of defective existing battery lead (Heavy duty) PVC insulated copper conductor single core multi stranded minimum 25 Sqmm one side fixed with clamp and other side fixed with brass battery terminal of heavy duty for 3 Mtr length (Set of two)
Supply and fixing in repairs for unserviceable MS sheet of suitable thickness for DG sets/ panel boards and similar works, cut to size / shape, hole punched, including round headed screws, clout nails or rivets, bending and welding as necessary, etc.conforming to Fe.290.Gde-E-165, with and including applying two coats of synthetic enamel paint over a coat of red oxide primer with lap of 40 mm joints complete all as specified and directed.
Labour only for daily basis complain for minor repair of engine ,panel,alternator and its testing on installation complete, by employing one DG set mechanic on receving the complaint slip from MES Service Centre and returning the same after dully completing the job to MES Authority complete,all as specified and directed.
Supply and replacement of Rotary pump with suction pipe not less than 1 Mtr complete all as specified and directed.
Supplying, fixing, testing and commissioning in replacement ofof front operated ON Load type changeover switch 4 pole, 415 volts, 200 Amps without sheet enclosure complete all as specified and directed. Cat part No: IHCNFO0200 of make Havells or Make: Indo Asian equivalent in Legrand/Indo Asian/Schnieder / L&T
Material & ,labour in replacement of UNSV Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC complete, all as specified and directed.
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed. Note: (Applicable for Sch ‘A’ Item No.102 & 103). (i) Window/Split type AC's shall be taken from department on "as and where installed" basis. (ii) Window/Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.102& 103). (iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (vi) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed.. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 1.5 TR window/Split type AC complete, all as specified and directed (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 2.0 TR window/Split type AC complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for window type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for Window type AC 1.5 ton/2.0 ton capacity 1/5 HP, 220 Volts, single phase complete,all as specified and directed.
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed.
Supply only cooling coil unit for window type AC of any type/ any capacity complet, all as specified and directed .
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
M&L for replacement of unserviceable door Invertor type PCB suitable for 1.5/2.0 TR split type AC complete, all as specified and directed. (Make : Blue Star / Alloyds )
M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed. (Make : Universal/Sarda )
M&L for replacement of unserviceable indoor Invertor type PCB suitable for 1.5/2.0 TR split type AC complete, all as specified and directed. (Make : Blue Star / Alloyds )
M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable thermostat suitable for window type Ac 1.5 ton/2.0 ton capacity complete, all as specified and directed. (Make : Indofoss or equivalent as approved).
M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable operation knob fro window type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable PVC air filter for window type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable fan blade for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed . (Make : Carrier/Hitachi/LG )
M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed.
M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed.
M&L for replacement unserviceable wiring for AC window type /split type 1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete, all as specified and directed.
Supply and fixing in replacment of UNSV refrigerant copper tubing 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed.
Supply and fixing in replacment of UNSV foam type insulation sleeve for copper tubing 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed.
M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific
M&L for replacement of unserviceable PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed (Make : KDK/Nicco/Finolex/Havells)
M&L for replacement of unserviceablePVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed. (Make : KDK/Nicco/Finolex/Havells)
M&L for dismantling of storage type water cooler of 40/80/150 ltrs capacity of existing model in various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and sticking a sticker mentioning the “No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified. (NOTE: The spare parts ( ie compressor, blower motor) measured & paid separately as supply only rates. Rates for fixing of spares parts under the unit rate quoted by the contractor for this item.
Supply only new compressor sealed unit of 40/80 ltrs capacity of existing model in the unit properly for storage type water cooler of any type complete, all as specified and directed . (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new compressor sealed unit of 150 ltrs capacity of existing model in the unit properly for storage type water cooler of any type complete, all as specified and directed. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed.
Supply only blower motor including fan blade, capacitor complete suitable for 150 ltrs capacity, 220 volts, single phase all as specified and directed.
Supply only new condensing coil unit suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed.
Supply only new condensing coil unit suitable for 150 ltrs capacity, 220 volts, single phase complete, all as specified and directed.
M&L for charging refrigerant gas in the system of water cooler of any capacity complete, all as directed. Note : The refrigerant gas measured and paid separately under relevant items as applicable as supply only).
M&L for replacement of unserviceable capillary tube and stainer for storage type water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable overload protection coil 230 volts for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable relay suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed. ( Make : Indfoss / Usha / Arvind)
M&L for replacement of unserviceable thermostat suitable for water cooler of 40/60/150 ltrs capacity icomplete, all as specified and directed. (Make : Indfoss/Asian).
M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 Volts AC for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed. (Make : Indfoss/Sarda )
M&L for replacement of unserviceable running capacitor suitable for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed. (Make : Indfoss/Sarda).
M&L for replacement of unserviceable fan blade for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable capacitor for blower motor suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed.
M&L for replacement of unserviceable internal wiring of AC, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete.
M&L for replacment of UNSV of head cover gasket for water cooler of 40/60/150 ltrs capacitycomplete, all as specified and directed.
M&L for dismantling of storage type refrigerator/freezers of 165/212/310 ltrs capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and eassembling, testing, checking and shifted to existing location including masonry work complete, all as specified and directed. (NOTE: The spare parts ( ie compressor, cooling unit ) measured and paid separately as supply only rate. Rates for fixing of spare parts under the unit rate quoted by the contractor for this item.
Supply only new compressor seal unit of 165/212 ltrs capacity of existing model in the unit properly for domestic refrigerator/freezers of any type all as specified and directed.
Supply only new compressor seal unit of 310 ltrs capacity of existing model in the unit properly for domestic refrigerator/freezers of any type all as specified and directed.
Supply only freezer coil unit for domestic refrigerator of any type/ any capacity complet, all as specified and directed.
M&L for charging refrigerant gas in the system of domestic refrigerator of any type/ any capacity complete, all as directed. (Note : the refrigerant gas measured and paid separately under relevent items as applicable as supply only ).
M&L for replacement of unserviceable capillary tube and stainer for any type and capacity complete for domestic refrigerator/freezer,complete, all as specified and directed.
M&L for replacement of unserviceable timer/bimetallic relay of existing type for domestic refrigerator/freezer, complete, all as specified ans directed.
M&L for replacement of unserviceable over load relay for domestic refrigerator/freezer of any type/ any capacity complete, all as specified ans directed.
M&L for replacement of unserviceable thermostat for domestic refrigerator/freezer of any type/any capacity complete, all as specified ans directed.
Supply only refrigerant gas R-22.
Supply only refrigerant gas 134A.
Supply only refrigerant gas R-407/R-410/R-32 (HYDRO CARBON)
M&L for replacement of angular valve of size 1/2" suitable for split type AC complete, all as specified ans directed.
M&L for replacement of angular valve of size ¼" suitable for split type AC complete, all as specified ans directed.
M&L for replacement of angular valve of size 5/8" suitable for split type AC complete, all as specified ans directed.
M&L for replacement of angular valve of size 3/8" suitable for split type AC complete, all as specified ans directed.
Supply only Remote control for split/ Window type AC of LG/Samsung/existing make of 1.5 TR/2 TR with battery complete, all as specified ans directed.
M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/4 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition complete, all as specified ans directed. (Note :- The spare parts measured and paid separately as supply only rates. Rates for fixing of spare parts under relevant items shall be included in item)
Supply only transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 3/4/5 KVA of approved make complete all as specified and directed. .
Supply only relay 12/24 volts suitable for 3/4/5 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make complete all as specified and directed.
Supply only electromechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round for stabilizer as per requirement complete all as specified & directed. Make – AE or equivalent approved.
Supply only DC electronic circuit for relay of capacity 24/12 volts stabilizer for 3 to 5 KVA of approved make complete all as specified & directed.
Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp of approved make & existing shape and size complete all as specified and directed.
Supply only toggle switch 20/30 Amp two way of approved make complete all as specified and directed.
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.102 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete, all as specified ans directed.
Supply &Fixing in replacement of unserviceable Oudoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity, complete, all as specified ans directed.
Supply &Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity, complete, all as specified ans directed.
M & L for preparation of the steel surfaces of desert cooler and applying one coat of synthetic enameled paint on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces and writing MES No of the desert cooler in the pattern as approved with different tint / colour complete all as specified and directed.
Supply &Fixing in replacement of unserviceable PVC distributor 3 way, suitable for 15mm dia water distribution complete all as specified and directed.
Supply &Fixing in replacement of unserviceable wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply &Fixing in replacement of unserviceable Water circulating pump 1/ 70 H P capacity single phase 230 volts, 1340 RPM, 1.5 Mtr head suitable fot any make any capacity of Desert cooler Make : AUE / CG/ Kaithan
Supply &Fixing in replacement of unserviceable plug top 3 pin, 15/16 Amp capacity complete all as specified and directed. Make : Anchor (Penta deluxe) or equivalent as approved by GE.
Supply &Fixing in replacement of unserviceable Fan motor double speed 230 volts, 50 HZ 1/13 HP complete suiable for any make and any capacity of Desert cooler make Cool Home/AUE.
Supply &Fixing in replacement of unserviceable Capacitor suitable for any type any capacity of desert cooler fan motor complete
Supply &Fixing in replacement of unserviceable Regulator for any type any make of Desert cooler
Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location.Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.complete, all as specified ans directed. Note :- Spare parts if any requires replacement shall be measured and paid for separately.
Disconnecting and taking down the existing Geyser of any description and any capacity (25 / 50 Ltrs) and any position from the existing location and Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , base assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved , brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction Note :- Spare parts if any requires replacement shall be measured and paid for separately
Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete, all as specified and as directed.
Supply only MS base plate cup any type with screws of suitable size as per requirement complete, all as specified ans directed.
Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified ans directed.
Supply only Steel inner tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified ans directed.
Supply only Steel inner tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified ans directed.
Supply only Insulating material (glass wool for Geyser)complete, all as specified ans directed.
Supply only Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only Base assay complete with inlet, out let and pipes with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut, bolt and washers fsuitable for 25 Liters cap to 50 Liters cap complete, all as specified ans directed.
Supply only Non return valve 15 mm dia cast copper alloy ISI mark complete, all as specified ans directed.
Supply only Safety valve/Fusible plug 15mm complete, all as specified ans directed.
Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified ans directed.
Supply only PVC connecting tube 450 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by GE.
M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed.
M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing type complete all as specified and directed.
M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
M&L for Painting of geysers size 25/50 liter any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed.
Disconnecting , taking down & removing carefully the existing ceiling fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engr-in-Charge complete, all as specified ans directed.
Disconnecting , taking down & removing carefully the existing exhaust fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction complete, all as specified ans directed.
Disconnecting,taking down and removing carefully the existing table fan, Air circulator wall mounting fan,pedestal fan, of any description, any sweep and from any position / locations for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting the fans to existing electric sources and testing at site to the entire satisfaction complete, all as specified ans directed. Note for item 205 to item 206 here in before : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under item No 208 to 223 of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above. (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
Supplying only ball bearing No 6200 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6201 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6202 (Make SKF/NRB/NBC)
Supplying only ball bearing No 6203 (Make SKF/NRB/NBC)
Supply only gun metal bushes of any description and size to suit existing motor shaft.
Supplying only capacitor of capacity 2.5 mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA)
Supplying only capacitor of capacity 4 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)
Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts,bolts with lock pins suitable for any type of fans & down rods of length 300mm.
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for ceiling fans of any descriptions & of 1200/1400 mm sweep. Note: (i) Set of three blades shall be measured as one unit (ii) Make of the blade assembly shall be as approved by GE
Supplying only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 300/450 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for air circulator/wall mounting/table ans of any descriptions & of 400/610 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
Supply only PVC insulated and sheathed, round flexible cable, three core of size 0.50 Sqmm with copper conductor in pieces for connecting fans. ( Make :Havell’s / Finolex / Gloster / National/ Plaza )
Supply only MS nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete.
Supply only rubber reel bushof suitable size of hanging assembly complete.
Supply only MS tube medium grade 15mm dia duly finished with white colour two coats over a coat of red oxide cutting in desired length from 300mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction for the following Fans:-
Rewinding of motor of ceiling fans 1200 mm sweep.
Rewinding of motor of ceiling fans 1400 mm sweep.
Rewinding of motor of exhaust fan of 230/300 mm sweep.
Rewinding of motor of wall mounted fan of 400 mm sweep.
Rewinding of motor of air circulating fan of 610 mm sweep.
Rewinding of motor of table fan/ pedestal fan of 400 mm sweep.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 230/300mm sweep all as specified & directed. (Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers made out of MS sheet 22 gauge thick suitable for exhaust fan of 450mm sweep all as specified & directed ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
Disconnecting & taking out old existing unserviceable ceiling fan regulator of any description & in any position / location and Supply and fixing ceiling fan regulator electronic, step type suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified & directed. (Make :- Anchor/Cona/Leader)
Disconnecting and taking out old existing unserviceable ceiling fan modular regulator of any description and in any position/ location and supply and fixing ceiling fan modular regulator electronic, step type, 1M size modular type , suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified and directed. (Make :- Anchor/Cona/Leader)
Disconnecting & taking out old existing unserviceable ceiling fan modular regulator of any description & in any position / location and Supply and fixing ceiling fan modular regulator electronic, step type, 2M size piano type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified & directed. (Make :- Anchor/Cona/Leader)
M & L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including numbering etc, complete, all as specified ans directed.
M & L for painting of existing fans of any description of exhaust fan of 230/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans including numbering etc complete, all as specified ans directed.
M & L for painting of existing fans of any description Air circulators of 610 mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces including numbering etc complete, all as specified ans directed.
Supplying and fixing GI tubing 40mm, medium grade for hanging of ceiling fans including cutting holes in walls built in cement mortar and making good in cement sand mortar 1:4 and finish the surface to match with existing complete, all as specified ans directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed (NOTE : Thickness after punning shall be measured for payment)
M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed
Fixing / laying only old retrieved bricks of any description as obtained from dismantling of the cable complete all as specified and directed.
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BST or any other ISI marked make approved by GE. (Note : PCC work shall be measured and paid seperatly under Sch "A' relevent item)
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed . Make of pipe TATA / Jindal / Swastik / Prakash / BST or any other ISI marked make approved by GE. (Note : PCC work shall be measured and paid seperatly under Sch "A' relevent item)
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete, all as specified ans directed. Make :Havells/GLOSTER/Polycab) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
10 Sqmm 2 core
16 Sqmm 2 core
16 Sqmm 4 core
25 Sqmm 4 core
95 Sqmm 3½ core.
120 Sqmm 3½ core.
150 Sqmm 3½ core.
Re-laying LT cable Obtained form Item No.249 to 255 ( Any size)
Supplying, Fixing, jointing and testing in replacement of UNSV straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade of size 120 Sqmm 3.5 core cables complete, all as specified ans directed. (MAKE : M.SEAL/DENSON/ MAHINDRA CHEMICALS/3M) :-
Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED,HPSV, Metal Halide, flood light fittings etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed here in after in notes. NOTES FOR SCH `A’ ITEM NO : 258:- (i) Replacement of parts i.e Drivers,SPD, LED board,lamps, choke, Igniter, Condenser, Holder, covers etc for Street/Flood light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A' as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A' item No 258 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
Supply only the following parts for LED fittings complete all as specified and directed. NOTES: (i) Fixing element of these items is deemed to be included in the rates quoted by the contractor for Sch `A' item No 258 (ii) Spare parts/items shall be of make Crompton Greaves/Philips/Bajaj/Havells & suitable for the existing fittings. (iii) The above items shall be operated with prior written approval of GE and when required spares are not available with the deptt to issue to contractor under Sch ‘B’ “Free for fixing” and Contractor shall have no claim on account of non execution of above items.
Driver Suitable for 45/48Watt LED fittings.Make:C&S/Havells/Bajaj/Crompton
Driver Suitable for 60Watt LED fittings, Make:C&S/Havells/Bajaj/Crompton
Driver Suitable for 90Watt LED fittings,Make:C&S/Havells/Bajaj/Crompton
Driver Suitable for 100/120/150Watt LED fittings. Make:C&S/Havells/Bajaj/Crompton
Safety Protection Device (SPD). Make:C&S/Havells/Bajaj/Crompton
M&L for making holes in electric/street light poles of any height or in any shape, by means of drill machine and drawing of drawing of 1.5sqmm x3 core cable through the hole from junction box to the hole on the top of pole near the street light fitting complete with all electric connections complete all as specified and directed (Rates of the cable deemed to be included)
Taking down existing unserviceable bracket complete and S&F 40 mm dia GI light grade pipe bracket 1.50 m long bent to shape by cutting & welding as required & directed and fixed to pole with two No,s of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make of pipe TATA / Jindal / Swastik / Prakash / BST or any other ISI marked make approved by GE.
Supply and fixing in replacement of UNSV 20W LED Post top lantern complete accessories to be fixed on pole/wall including connecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed. Make : Crompton/ Havells/ C&S/Bajaj/ Surya). (Note :PCC work shall be measured and paid seperatly under Sch "A' relevent item and rate of cable deemed to be included )
Supply and fixing in replacement of UNSV 40W LED Post top lantern complete accessories to be fixed on pole/wall including connecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed. Make : Crompton/ Havells/ C&S/Bajaj Surya). (Note :PCC work shall be measured and paid seperatly under Sch "A' relevent item and rate of cable deemed to be included )
Taking down old unserviceable MS junction boxes from the pole with disconnectiong all connections, Supplying and fixing in position new Pole box made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, dust proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/ 60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-moulded knock out /or plan wall depending on requirement. Box dimension shall not be less than 200 X 160 X98 MM (LXBXH). Box shall be suitable for 16/25Sqmm cables including one no. MCB SP 230 volts 6 amps of make Havells/Legrand/ABB and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps,nuts,bolts & washers complete all as specified and directed. Make: Hensel/GE/Legrand/ Sintex
Material & labour of PCC 1:3:6 type C-2 using 20 mm graded stone aggregate (4 stay). in mass concrete and filling complete for foundation/hard standing , complete all as specified and directe
M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of cutting and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed.
Supplying,erecting and fixing in replacement of UNSV steel tubular swaged pole (410 SP – 31), 9 mtr long,in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete all as specified and directe (Note : Excavation and PCC work shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 15W LED street light with corbonate cover with high inpact resistance, 15 W-1500 lumens with efficacy of 100 lumans /wall at system level, ingress protection of IP65 PF-0.9 & with input resistanct i.e.IK 09 surge protectin upto 4KV,compiled with IS 10322 CCT is greater than 5000K,complete with all accessories duly prewired, supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade bent to shap and including MS FI clamp of 20X3 mm nut and bolts and connected with flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete, all as specified and directed. (Make- Crompton / Havells/C& S/Bajaj Surya).). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 45W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. (Make- Crompton / Havells/C& S/Bajaj Surya).). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 60W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. (Make- Crompton /Havells/C& S/Bajaj). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. (Make- Crompton /Havells/C& S/Bajaj /Surya) (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 120W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. (Make- Crompton / Havells /C& S/Bajaj/Surya). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV 120W LED Flood light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS frame/ bracket including connecting the fitting complete all as specified and directed. (Make- Crompton/Havells/C& S/Bajaj/Surya). (Note : GI pipe bracket shall be measured and paid seperatly under Sch "A' relevent item)
Supply, fixing & testing in replacement of UNSV LED highbay/mediumbay LED IP 65 luminaire with high efficiacy light fittings 150 watts with all aecessaries complete on Pole and building wall/ ceiling complete, all as specified and directed. (Make- Crompton/Havells/C& S/Bajaj/Surya).
Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 9 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole complete all as specified and directed.
Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 11 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole complete all as specified and directed.
Supply only earth enhancing compound resistance lowering GEL complete all as specified and directed. Make:- DSS
MAHADEV ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .