Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.7 L+₹15,403.50 (2.04%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹7.8 L+₹21,876.80 (2.90%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹8.2 L+₹67,728 (8.99%)Rejected-Finance 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹87.3 L+₹79.7 L (1058.5%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹10.7 L
EMD Value
₹21,400
Closing Date
7 Jul 2025, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun 248003
PROVN OF LT PANEL UG CABLE AND ALLIED WORKS IN 332 MED REGT UNDER AGE(I) RAIWALA
2025_MES_714059_1
86452/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE (I) Raiwala
Class E Cat b (i)
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Raiwala
₹21,400
Yes
25 Jul 2025
12 Jun 2025
15 Jul 2025
12 Jun 2025
7 Jul 2025
30 Jun 2025
Amount
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Out door type with minimum size 0.9m(L)*0.45m(B)*1.20m(H) , totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded aluminium conductor FRLS cable of adequate size (minimum 1.5 sqmm ), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar is made of aluminium : The incoming as well as outgoing MCCBs is shall have extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link should be supported on DMC/Epoxy insulator and should have provision for termination of incoming and outgoing cables.
Outgoing : (a) (i) MCCB 63 Amps, 16 KA,415Volts, 4 pole 50 Hz, 1with adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete including phase spreader 01 Nos. (ii) MCCB 40Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete including phase spreader-01 Nos.
(i) CPRI Certification Degree of protection IP-54 (should have IEC:61439-1-2 & IEC:60529 tests). (ii) All the electrical switch gear like MCCBs, MCBs should be of same make, (iii) Drawing of panel board should be got approved from AGE(I) before fabrication.
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Out door type with minimum size 0.9m(L)*0.45m(B)*1.20m(H), totally enclosed, dust and vermin proofm suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded aluminium conductor FRLS cable of adequate size (minimum 1.5 sqmme), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar is made of aluminium : The incoming as well as outgoing MCCBs is shall have extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link should be supported on DMC/Epoxy insulator and should have provision for termination of incoming and outgoing cables.
Outgoing : (a) (i) MCCB 100 Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete including phase spreader-01 Nos. (ii) MCCB 63Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete including phase spreader- 01 Nos. (iii) MCB 25 Amps, 415Volts, 4 pole 50 Hz, 10 KA,TPN B Series , Ics = 100%=Icu(1 sec) complete including phase spreader - 01 No complete all as specified and directed.
(i) CPRI Certification Degree of protection IP-54 (should have IEC:61439-1-2 & IEC:60529 tests). (ii) All the electrical switch gear like MCCBs, MCBs should be of same make,(iii) Drawing of panel board should be got approved from AGE(I) before fabrication.
M&L for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Out door type with minimum size 0.9m(L)*0.45m(B)*1.20m(H), totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded aluminium conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar is made of aluminium : The incoming as well as outgoing MCCBs is shall have extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link should be supported on DMC/Epoxy insulator and should have provision for termination of incoming and outgoing cables complete all as specified and directed.
Outgoing : (a) (i) MCCB 63 Amps, 415Volts, 4 pole 50 Hz, 16 KA adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complte including phase spreader-01 Nos (ii) MCCB 40Amps, 415Volts, 4 pole 50 Hz, 16 KA adjustable thermal and adjustable magnetic type ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) - 02 No
(i) CPRI Certification Degree of protection IP-54 (should have IEC:61439-1-2 & IEC:60529 tests). (ii) All the electrical switch gear like MCCBs, MCBs should be of same make, (iii) Drawing of panel board should be got approved from AGE(I) before fabrication complete all as specified and directed.
S&F Bus bar chamber made out of 3.15 mm thickness sheet metal enclousre totaly enclosed outdoor type, vermin proof, powder coated paint, metal clad with porcelain insulator and colour coated tinned aluminium bus bar 415 volts, 200 Amps rated, 4 pole for connecting UG cable, fixed on ground or as per site requirement, in outer site the letters shown Danger 440 volts in black colour all as specified and directed.
Supply and laying , fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 185 Sqmm sqmm 3.5 core including aluminium lugs of suitable size complete with all as specified and directed.
All as per item No. 5 here-in-before but 150 sqmm 3.5 core complete all as specified and directed.
All as per item No. 5 here-in-before but 70 sqmm 3.5 core complete all as specified and directed.
All as per item No. 5 here-in-before but 25 sqmm 3.5 core complete all as specified and directed.
All as per item No. 5 here-in-before but 16 sqmm 4 core complete all as specified and directed.
All as per item No. 5 here-in-before but 10 sqmm 2 core complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus soil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose.
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
M&L for road cutting for laying cable and through GI Pipe of suitable size making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as directed by Enger -in- charge.Note: GI pipe should be deemed to be included in the quoted rate.
S&F galvanized steel water tubing 50 mm bore (GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed. Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.
S&F in LT cable termination straight through joint for 1100 volts grade cable for outdoor termination cold shrink type complete with jointing material and accessories including making all necessary connection suitable for XLPE armoured aluminium conductor cable of size 70 Sqmm 3½ core complete all as specified and directed.
KAPOOR ELECTRICALS (BID ID -3349655)
M/S ROORKEE ENGINEERING (BID ID -3347280)
M/S K K ENTERPRISES (BID ID -3350507)
M/s badrinath Traders (BID ID -3350450)
TARUN ENGINEERING WORKS (BID ID -3348761)
M/S Konark Electric Sales Corporation (BID ID -3350026)
JAGDEEP SINGH (BID ID -3350530)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .