Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Technically Not Selected |
Tender Value
Refer Docs
EMD Value
₹37,500
Closing Date
7 Oct 2023, 5:00 pmClosed
Director
Regional Cancer Centre Medical College Campus Medical College PO
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF SPLIT AIR CONDITIONERS AT VARIOUS LOCATIONS OF RCC
2023_RCC_586365_3
RCC/ENG-M/2023-24/E-87
Open Tender
Equipments
Item Wise
30 days
RCC-TVM
Please refer Tender documents.
14 documents required · 14 mandatory
₹2,950
Yes
₹37,500
Yes
21 Nov 2023
23 Sept 2023
9 Oct 2023
23 Sept 2023
7 Oct 2023
25 Sept 2023
25 Sept 2023 - 7 Oct 2023
SITC of Split Air Conditioners
Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU),FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU), R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit - 02 TR
Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU), FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU), R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit 1.5 TR
Supply, installation, testing and commissioning of following capacity inverter type Wall mounted Split AC unit having minimum 03 star rating of BEE complete with indoor unit (IDU), Outdoor unit (ODU), surface /concealed copper refrigerant piping with 13 mm thick nitrile thermal insulation up to 3 Mtr. (IDU to ODU), FRLS Power and control cables of copper conductor of suitable size up to 4 Mtr. length (IDU to ODU),R410A refrigerant or refrigerant with better ODP/GWP, Cordless remote controller and suitable for working with 400/230V +10% of 50 Hz, 1/3 phase AC supply. Indoor unit with DX cooling coil, rough filter and air outlet with horzontal and vertical automatic rotating deflecters. Air cooled condensing unit complete with Scroll / Rotary compressor, axial type condenser fans, condenser coil. Unit shall meet relavant IS standards and the installations to be carried out as per relevant CPWD specification and OEM recommendation. Inverter type Wall mounted Split AC unit 1.0 TR
SITC of 2.7 KVA capacity voltage stabilizer for split air conditioners working with 230V +10%, 50 Hz, single phase phase AC supply and all accessories
SITC of 3.35 KVA capacity voltage stabilizer for split air conditioners working with 230V +10%, 50 Hz, single phase phase AC supply and all accessories
Supply and fixing of MS powder coated/GI painted ODU stand for split Air conditioners with all accessories
SITC of extra 40 mm dia PVC drainline with thermal insulation after 4 Mtr
SITC of extra copper piping connecting between ODU and IDU with 13 mm thick nitrile thermal insulation after 3 Mtr
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .