| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.7 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹83.0 L+₹6.5 L (8.51%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L2 | Rejected-AOC REJECT | |
| 3 | L3₹87.4 L+₹10.9 L (14.2%)Rejected-AOC | L3 | Rejected-AOC REJECT | |
| 4 | L4₹1.2 Cr+₹41.0 L (53.6%)Rejected-AOC | L4 | Rejected-AOC REJECT | |
| 5 | Rejected-Technical 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | - | Rejected-Technical Reject |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
10 Nov 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
PROVISION OF REPAIR STREET LIGHT FITTING WITH LED STREET LIGHT AND PROVISION OF LED SECURITY LIGHTS ALONG PERIMETER FENCING OF CLEMENT TOWN
2021_MES_480547_1
85025/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Clement town
Class C cat b i
6 documents required · 6 mandatory
₹1,000
GE Clement Town
₹1.8 L
Yes
24 Nov 2021
8 Oct 2021
12 Nov 2021
8 Oct 2021
10 Nov 2021
28 Oct 2021
8 Oct 2021 - 13 Oct 2021
Amount
Taking down existing U/S HPSV/MH light fitting any size /cap for further disposal complete all as specified and directed.
All as per item No 1 above but serviceable fittings of any size/cap complete all as specified and directed.
Taking out old unserviceable Under Ground LT cable of Size 10 x 02 core from Trench/GI Pipe/ Wall/Floor/Pole for further disposal complete all as specified and directed.
Taking out old unserviceable Under Ground LT cable of Size 16 x 04 core from Trench/GI Pipe/ Wall/Floor/Pole for further disposal complete all as specified and directed.
Taking out old unserviceable GI breacket of 40mm dia fixed to steel tubular pole including MS clamp of size 40x5 mm flat iron and nuts, bolts etc complete all as specified and directed.
Supply and fix new LED street light fitting with DPSD energy saving dimming system (to reduce down the light output upto 50% after certain period of time ) of 60 watts housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiciency> 120 lumens /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K on bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade from distribution / pole box to light fitting complete all as specified and as directed by Eng-in-Charge. Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No (iv) 1.5 sqmm PVC insulated copper condctor cable 1100 volts grade will be measured and paid seperatlely .Make of fittings - Havells , wipro , Shakti
Supply and fix new street light fitting with DPSD energy saving dimming system (to reduce down the light output upto 50% after certain period of time ) of 75 watts housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K on bracket including necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution/ pole box fitting to light complete all as specified and as directed by Eng-in-Charge. Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No (iv) 1.5 sqmm PVc insulated copper condctor cable 1100 volts grade will be measured and paid seperatlely .Make of fittings - Havells , wipro , Shakti
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 10 sqmm 2 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 10 sqmm 4 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 4 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
S&F thermoplastic cable junction box /enclosure (distribution box) for outdoor installation with knockouts for cable entry suitable for cable size 10-16 sqmm of dimension 300 x 200 x 100 mm with cable terminals and 01 No MCB(0-5 Amp) 10 KA, B curve ,230 volts complete fitted on pole with suitable size MS clamps FI nuts bolts and washers and painting with two coats of synthetic enamelled paintover one coat of red oxide Zink crome primer on clamps complete all as specified and directed. Make of box :- Sintex/Hensel
Supply and lay in trenches/fixed on wall GI tubing light grade of Size 40 mm dia with necessary fittings such as bend, tee,elbow etc complete all as specified and directed.
Supply and fix cord flexible 2 core 1.5 Sqmm copper conductor PVC insulated from pole box to connector of street light fitting through PVC conduit complete all as specified and directed.
S& F digital timer switch box made out of 3 mm thick CRCA sheet powder coated degree of protection IP 54suitable for 3 phase 415 V AC supply for street light feeder programmable 1 minute with backup of 6 years,28 memory location weekly programe with one changeover total 28 programe DIN type daily/weekly with 32 Amps rating contractor with controller MCB triple pole 40 Amps inside of appropriate size with locking arrangement complete including mounting/grouting on angle iron frame or fixed to LT pole with MS clamps 40X5mm FI nuts bolts and washers and painting with two coats of synthetic enamelled paintover one coat of red oxide Zink crome primer on clamps complete all as specified and directed. Make of Box-Indoasian Cat part No. TL032DB0, Havells Cat Part No. IHXTS03060 or equivalent in BCH
S&F Bus bar chamber factory made outdoor type powder coated , degree of protection IP-54 made out of 3.00 mm CRCA sheet of size 700x450x300mm Pedestal type with 200 Amp rated aluminium bus bar TPN system including 40x40x6 mm angle iron frame for mounting and comprising with one No of MCB (6-32) Amp 4 Pole,10 KA complete all as specified and directed.Note -The drawing of bus bar chamber shall be got aproved from GE. Make- Indoasian Havells , BCH
M&L for replacement light grade GI bracket made out of 32 mm dia light grade pipe 1.2 mtr long bend to shape as directed fixed to steel tubular pole with two number MS clamp made out of 40x5 mm flat iron duly painted with two coats of synthetic enamelled paint over one coat of red oxide Zink crome primer with and including nuts, bolts etc complete all as specified and directed.
Dismantaling of existing old U/S steel tubular pole carefully by breaking PCC coping Excavation and stacking proprerly for further disposal complete all as specified and directed.
Supply, transporting, errecting in truely vertical position , steel tubular swaged pole 9.0 Mtrs long , type 410-SP-31 complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts washers and hooks for earthwire duly ISI marked as per IS :2713 including necessary earthwork and excavation PCC foundation in PCC 1:4:8 type D2 using 40mm graded stone aggregate and PCC 1:3:6 type C2 using 40mm stone aggregate as in plinth block,disposal of surplus soil to a distance not exceeding 50m painting two coats of Al paint over one coat of red oxide primer including 05 nos band/strips with different color (250mm wide each) synthetic enamel paint ( two coat over a coat of red oxide primer) at a distance 250mm from plinth block,marking poles number with black synthetic enamel paint including tarring one coat on steel surface embeded in concrete complete all as specified and directed.Note :- Earthtwork (excavation, returning filling, Removal of soil , PCC 1:4:8 and PCC 1:3:6 will be measured and paid seperately
M&L steel work in FE-410-S grade for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer, one under coat and two finishing coat of aluminium paint complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size of PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Supply and fix medium grade rigid PVC conduit ISI Marked of size 20 mm exclusive of boxes(junction/terminal)but inclusive of all tees, bends, elbows, reducers,bell mouth tube ends and fixing acessaries such as couplers lock nuts,saddles, pipe hooks etc complete all as specified and directed.
M&L for PCC/ road cutting for laying of pipe/cable exceeding 500 Sqcm & not exc 1000 sqcm in cross sectional area and making good with PCC 1:2:4 type B-1 using 20mm graded stone aggragate, complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M&L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable (measurement to be taken after punning down consolidated thickness). complete all as specified and directed.
Supply and laying , un-reinforced factory fabricated precast concrete cable cover ISI Marked ,class LV,Type I,flat,size 250mmX150mmX40mm with breaking load capacity 200 KG complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggrigate) as in coping of poles above grounding including necessary form work, complete all as specified .
Material and labour for cement concrete 1:3:6 (40mm graded aggregate ) type C-2 for foundation of poles including necessary form work complete all as specified and directed.
M/s Kamal Traders
Ravi Electrical
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .