EXECUTIVE ENGINEER AGRI MECH PURULIA
WILLCOX ROAD, BELGUMA, PURULIA.
Renovation of WTA and Construction of New Pump House of Baramasiya Major RLI Scheme at Mouza- Baramasiya, Block-Ragunathpur-I in the District of Purulia under the EE (A-M), Purulia (A-M) Division under Core-Sector Program for the FY 2025-26
2026_WRDD_986624_2
WBWRDD/EEAM/PUR/eNIT-09(Sl No.-01 - 02)/CS/2025-26
Open Tender
CIVIL WORKS
90 days
At Mouza- Baramasiya, Block-Ragunathpur-I
Please refer Tender documents.
4 documents required · 4 mandatory
₹97,000
17 Feb 2026
10 Jan 2026
29 Jan 2026
10 Jan 2026
27 Jan 2026
10 Jan 2026
RENOVATION OF WTA FOR Baramasiya GOVT. OWNED AND OPERATED MAJOR RLI SCHEME(E) UNDER RAGHUNATHPUR-I BLOCK UNDER PURULIA-I (A-M) SUB-DIVISION UNDER PURULIA (A-M) DIVISION UNDER CORE SECTOR PROGRAMME 2025-26 Please see the details in Sheet Pump House (A)
Procurement of Materials for Baramasiya GOVT. OWNED AND OPERATED MAJOR RLI SCHEME(E) UNDER RAGHUNATHPUR-I DEVELOPMENT BLOCK UNDER PURULIA-I (A-M) SUB-DIVISION UNDER PURULIA (A-M) DIVISION UNDER CORE SECTOR PROGRAMME 2025-26 Please see the details in Sheet Materials (B)
REPAIRING OF PUMP HOUSE AT Baramasiya GOVT. OWNED AND OPERATED MAJOR RLI SCHEME(E) UNDER RAGHUNATHPUR-I DEVELOPMENT BLOCK UNDER PURULIA-I (A-M) SUB-DIVISION UNDER PURULIA (A-M) DIVISION UNDER CORE SECTOR PROGRAMME 2025-26 Please see the details in Sheet Internal wiring (C)
ELECTRICAL CONNECTION TO MOTOR AND INTERNAL WIRING IN THE PUMP HOUSE REQUIRED FOR ENERGISATION OF Baramasiya GOVERNMENT OWNED & OPERATED MAJOR RLI SCHEME WITHIN RAGHUNATHPUR-I DEVELOPMENT BLOCK UNDER PURULIA-I (A-M) SUB-DIVISION UNDER PURULIA (A-M) DIVISION UNDER CORE SECTOR PROGRAMME 2025-26: Please see the details in Sheet WTA (D)
BoQ_Ver3.0
Tender Reference No : WBWRDD/EEAM/PUR/eNIT-09(Sl No.-01 - 02)/CS/2025-26, (Sl No- 02)
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
RENOVATION OF W.T.A AT Baramasiya GOVT. OWNED AND OPERATED MAJOR RLI SCHEME UNDER RAGHUNATHPUR-I BLOCK UNDER CORE SECTOR PROGRAMME 2025-26
Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. a) 315 mm dia PVC Pipe
b) 200 mm dia PVC Pipe
c) 140 mm dia PVC Pipe
Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. B) Do by Fibe sand
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur vareity .
250 mm thick Brick work with Fly Ash Bricks(250mmx125mmx75mm) as per IS 12894:2002 in cement mortar (1:6), (a) In foundation and plinth.
(a) 125 mm. thick Flyash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. Complete.
Labour charges for fitting and fixing 150 mm. dia Alfa-Alfa valve with 160 mm. dia class-II U.P.V.C riser pipe with the help of flanged P.V.C tail piece by joining the P.V.C end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion , nuts and bolts etc. complete (Rate inclusive of transportation from departmental store to work site)
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.
(xxviii) 150 mm dia sluice Valve
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of ordinary cement concrete (1:2:4) with graded stone chips (20mm. nominal size) of pakur varity of 1250 mm X 1250 Each 2263.08 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all aterials and labour and as per direction of Engineer-in-Charge.
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme ( one at rode side and other at site) the board will be made 3 mm thick MS plate of 300 mm X 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-I) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soilng. This will include one materials and labour complite as per drawing and direction of EIC.
Installation of Diesel Engine pumping set/Electro Motor Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally).
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge.
Carriage charge on every item from Sl. no-1 to 18 excluding Sl. No-1, 2, 4 & 18.
1. Total of Item No. (1 to 19)
2. Add GST @ 18 % (On Sl No. 1)
3. Sub Total (Sl No. 1+On Sl.No. 2)
4. Add Labour Cess @ 1 % (On Sl No. 3)
5. Sub Total (Sl No. 3+On Sl.No. 4)
6. Say Total
Rupees Nine Lakh Sixteen Thousand Seven Hundred and Eighty Four only.
BoQ_Ver3.0
Tender Reference No : WBWRDD/EEAM/PUR/eNIT-09(Sl No.-01 - 02)/CS/2025-26, (Sl No- 02)
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
(A) P.V.C. PIPES & ACCESSORIES
315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II)
200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II)
140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II)
140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II)
200 mm dia P.V.C. Equal Tee
140 mm dia P.V.C. Equal Tee
315 mm dia F.T.P.
200 mm dia F.T.P.
160 mm dia F.T.P.
160 X 140 mm P.V.C. Reducer (Class-II)
200 X 140 mm P.V.C. Reducer (Class-II)
200 X 60º P.V.C. Bend
140 X 90º P.V.C. Bend
140 X 60º P.V.C. Bend
140 mm dia P.V.C. End Cap(Cl-III)
315 mm dia P.V.C.Extra Coupler (Class-II)
200 mm dia P.V.C.Extra Coupler (Class-II)
140 mm dia P.V.C.Extra Coupler (Class-II)
150 mm dia P.V.C. Flexible Suction & Delivery Hose pipe duly ISI certification mark & CIPET Tested.
Solvent Cement(Exra)(Medium duty)
B. M.S. ACCESSORIES
150 mm dia ISI marked Sluice valves pressure designation P.N.1.6 with hand wheel for water works purpose, C.I flanged type conforming to IS 14846/2000 with Amdt. No. 1&2. Components/parts of Sluice valves shall be manufactured from basic materials given in Table 1 of IS 14846/2000 with Amdt 1& 2. The valves shall be tested for (closed end test) against hydrostatic test requirement.150 mm Nominal Size C.I. Sluice Valve.
150 mm dia C.I (Nipple type)Alfa Alfa valve, type C with hand wheel, one wheel for four nos of valves.
300 mm dia MS "" Z "" bend made from MSERW pipe both end flange welded. Pipe as per IS 1239 and flange asper IS 6392/71,table 17
300(NB) x 150(NB) MS Reducer (300 mm length) with both end flanged (300 NB flange 20 mm thick, 12 hole & 150 NB Flange 12 mm thick, 8 hole in horizontally at 180 degree apart.
G.I 150 mm dia 90º M.S bend both end flanged as per IS Specification.
M.S. Hexagonal Head Bolts & Nuts bearing IS –1363(Part-I)/1992 of product Grade-C with latest amendments for Bolts & IS-1363(Part-3)/1992 of Product Grade-C with latest amendments for Nuts Properties/Class for Bolt-4.6 & for Nut-4,5. Both Bolts & Nuts.
C. ELECTRICAL MATERIALS
25 HP 3Ø Electromegnatic Star-Delta Motor Controllers with 4 pole heavy duty Power contactor, Single Phasing preventer and normal protective features, MCB, Indicators, Push bottoms, Ammeter & Voltmeter, All in IP54 enclosure of min 16swg, C R sheet steel, 10 tank process power coat painted and as per technical specification.
Main Switch 200 Amps AC TPN Sheet Metal enclosed rewireble type fuse main switch 415 volt 3 phase 50 cycle AC supply conforming to IS 13947 ( Part-3)/1993.
Main Switch 63 Amps AC TPN Sheet Metal enclosed rewireble type fuse main switch 415 volt 3 phase 50 cycle AC supply conforming to IS 13947 ( Part-3)/1994.
Busbar unit 200A, 4 copper bars 415 V, sheet metal(16 SWG) enclosed generally conforming to latest IS 8623:1993 & IS/IEC: 60947.
Synthetic Insulated Mat (6 mm thickness, size: 0.9 m X 0.6 m) of elastomeric Polymer material of mat class B, 11 KV as per IS 15652: 2006 ISI marked with Manufacturer’s Test & Guarantee certificate.
D. OTHER MATERIALS
Foundation Bolt manufactured from 20 mm nominal diameter MS rod as per IS 2062/1992. Total length of the bolt is 375±10 mm having welded head 80±10 mm in length & 20 mm in nominal diameter with nut
Rubber Insertion (for raised surface of Flange as per IS-6392)
Grand Total Rs.
Say Rs.
Rupees Thirty Three Lakh Sixty Thousand Four Hundred & Twenty Four only
BoQ_Ver3.0
Tender Reference No : WBWRDD/EEAM/PUR/eNIT-09(Sl No.-01 - 02)/CS/2025-26, (Sl No- 02)
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
1. PROCUREMENT OF RESOURCE MATERIALS FOR Baramasiya MAJOR RLI SCHEME(E) UNDER RAGHUNATHPUR-I DEVELOPMENT BLOCK
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). (B) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. A) Pakur Variety iii) For Purulia
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(d) with local hard black stone verity chips(churser broken)
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild Steel II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. a) In foundation & plinth.
b) In superstructure ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone a gregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [Bitument to be supplied by the Agency]
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thick
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. (a) 15 mm thick (1:6) proportion.
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
Supplying, fitting, fixing approved quality asbestos cement quality down pipe in positin with necessary clamps, nails including making holes in wall, floor etc. and cutting trenches in any soil or through masonry, concrete structures etc. if necessary and mending good damages including jointing materials complete. (i) 76.2 mm Dia.
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.
Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar, mending damages to wall and plaster two coats of paint of approved brand sand shade. Payment of mending good damages of wall & plaster and painting to be mase seperately. b) RCC ventilator of 20 mm thick upto 0.10 sqm area.
(a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I.Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rollingshutter in the room, painting two coats of approved aluminium paintover a coat of red lead primer complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats
1. Total of Item No. (1 to 22)
2.Add 4% carriage ( on item no- 2 to 22 except item nos 16 )
3. Sub Total (On Sl No.1+ On Sl.No.2)
4. Add GST @ 18 % (On Sl No. 3)
5. Sub Total (On Sl No.3+ On Sl.No.4)
6. Add Labour Cess @ 1 % (On Sl No. 5)
7. Sub Total (Sl No. 5+On Sl.No. 6)
8. Say Total
Rupees Four Lakh Eighty Four Thousand Two Hundred & Forty Six only
BoQ_Ver3.0
Tender Reference No : WBWRDD/EEAM/PUR/eNIT-09(Sl No.-01 - 02)/CS/2025-26, (Sl No- 02)
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
1ɸ Wiring ( For Lighting Load )
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection Lagrand Double Pole 32 A.
Wiring from MCB SS Enclosure to Busbar by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. as required.
b) 2X 22/0.3 (1.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. to light/fan point with piano key type switch (Anchor Make ) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works. [PVC casing capping and Switch board both on surface] (c) Avg Run 8 run meter
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. with S & F 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on PVC switch board on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (a) Onboard
Supplying and fixing of 6 -32 Amp Single Pole MCB on Switch Board as per direction of E.I.C.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
3 ɸ Wiring ( Motor Wiring )
Fixing only of 200 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall.
Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall .
Fixing only of 63 A, 415 V sheet steel TP main switch on Angle iron Frame on wall .
Fitting & fixing of Starter (Direct on Line or Star-Delta/Auto- Transformer) with Nuts & Bolts fixed on Angle iron frame on wall and making necessary connection with the electrical cables. iii) Star-Delta 1Auto-Transformer Starter (Above 15 HP upto 25 HP)
Meter loop connection with 1.1 K.V. Gr. 3½ core / 4 core 50 Sqmm P.V.C./ XLPE insulated & sheathed and armoured Aluminium Cable from Meter to incomming TPN Main Switch / Terminal. (Brand: Gloster/Havells/Finolex) d) For MAJOR RLI Scheme i) 50 Sqmm 3% Core Aluminium Cable
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex). [a] For Major RLI
(i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to Bus-bar]
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor]
Suppling & fixing of EI danger Board 20 cm x 30 cm (8"x12") in two distinguishing position . As per IEE regulation.
Excavation of soil for installation of Earth Electrode and filling & ramming (b) For Morrum Soil
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
Earthing with 50 mm dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr. long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm dia X 80 mm long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. below the ground level. a) By TATA-Medium G.I. Pipe.
(b) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. (a) Solid GI wire (i) No. 4 SWG
Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of Engineer-in-Charge. (iii) 20 H.P. Capacity
Fitting, fixing of wooden pannel board of size 6'X4'X1" on M.S clamp on wall.
Supply of wooden pannel board of size 6ft. X 4 ft. X 1 inch. With 6 nos M.S. Clam for Pump House wall mounting (As per relevant IS Code)
1. Total of Item No. (1 to 22)
2. Add GST @ 18 % (On Sl No. 1)
3. Sub Total (On Sl No. 1+ On Sl.No. 2)
4. Add Labour Cess @ 1 % (On Sl No. 3)
5. Sub Total (Sl No. 3+On Sl.No. 4)
6. Say Total
Rupees Forty Three Thousand Nine Hundred & Nineteen only
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
Tendernotice_2.pdf
PDF • 0.51 MB
Tendernotice_3.pdf
PDF • 3.23 MB
BOQ_2408717.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid