Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.8 LAccepted-AOC | ₹17.8 L | 1 | Accepted-AOC L1 Hence accepted |
| 2 | 2₹17.8 LSame as 1Rejected-AOC INFRA HOUSE CHURCH ROAD PALLINADA ERNAKULAM KERALA 682025 | ERNAKULAM | KERALA | 682025 | ₹17.8 LSame as 1 | 2 | Rejected-AOC L2 Hence rejected |
| Sl No | Description | Qty | Unit | INFRA ELEVATORS INDIA PVT LTD L2 | ATLAS ELEVATOR INDIA PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00Estimate | |||||
| 1.00 | OD302317/2024-2025:Supply and installation one 13 passenger Lift (Gear less and with machine room), Rated speed .1 M / Sec., Travel 16.0 metre (approximately), No. of floor and entrance served 3 Floors , 3 Landings (3 Doors), with / with out attendant with Micro Processor controller, Stainless Steel 304 hairline cabin with rear side one panel mirror
finish and mirror finish false ceiling, led lighting, strong air axial flow fan with diffuser and flooring with 20 mm thick granite slab. Available well size - 2100mm W x 2500mm D, Car size - 1100 mm Wide x 2000 mm Deep, Car entrance 900mm width x 2000 mm. Position of counter weight - left/right side of car. Construction of design and finishing of car body work - Stainless steel car with stainless steel car door false ceiling, led lighting, Strong air axial flow fan with diffuser, mirror and flooring with 20 mm thick granite slab. Car entrance - Automatic centre opening sliding stainless steel door as per ISS with provision for mechanical opening key and emergency vision panel. Call indicator and position - UP/DN direction indication shall be provided at all landings-LCD indication. Electric supply - Suitable for operating in three phase 415 V 50 Hz AC supply. 230V,50Hz , Single Phase 2 Wire system. Voltage stabilizer - Suitable capacity servo stabiliser for motor and controller. Indications, digital push buttons and other requirements - a)Car position ( Inside the car and at all landings-LCD indication), b)Call indicator ( Inside the car LCD indication), c)Push button for Door close, Door open ( Inside the car ), d)Emergency stop button( Inside the car ), e)Flush mounted switch for fan and light. ( Inside the car ), f)Non stop button (Inside the car ), g)Battery operated emergency LED lamp with rechargeable batteries, h)Battery operated alarm bell, i)Intercom wiring with one master unit with two slaves, j) Fireman's switch at main lobby, k)Auto /Attendant control ( Inside the car ). Door opening system - Infra red door opening system shall be provided for the entire length. Automatic Rescue Device - Automatic rescue device with an electronic controller and with suitable maintenance free batteries. The rescue operation shall act within 10 seconds of power failure. Winding handle - Manual winding wheel for car in case of an emergency. Safeties - a) Over speed governor, b) Buffers, c) Motor over speed protection, d) Phase reversal protection, e) Single Phase preventer, f) Final limit switch, g) Other safeties as per ISS. Control panel - Control panel shall be accommodated on dust and vermin proof of sheet metal enclosure. Tests - At site test as per IS to be carried out before handing over. Scope of work1)Supply of lift materials, 2)Minor civil works such as construction of buffer block in the pit machine room, foundation necessary for mounting the control panel, cutting pockets and grouting brackets for guide rails, grouting boxes for control units in the front side. This does not include correction of wall opening on the front side of the wall, 3) Scaffolding, 4) Door frame, 5) Supporting steel, 9) Free servicing for 36 months after handing over, 6) Electrical Inspectorate approval for lift installation, preparation of scheme and remittance of all fees and obtaining energization sanction from electrical inspectorate. Guarantee - Three year free warranty and maintenance after handing over. Company shall carry out free maintenance during warranty period & includes. a)Cleaning lift equipment, b)Lubrication of all parts, c)Replacing of lubricating oil when required, d)Checking and adjusting contacts, e)Replacing fusible items, alarm etc., f)Re charging batteries in case of drain / and or renewing of batteries if required, g)Replacing / rewinding motors if required. | 1 | no | 17,32,943 ₹17,32,943 | 14,03,000 ₹14,03,000 Lowest |
| 1.00 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 17,554 ₹17,554 | 3,500 ₹3,500 Lowest |
| 1.00 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door | 1 | each | 4,463 ₹4,463 | 1,800 ₹1,800 Lowest |
| 1.00 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 5 | each | 318 ₹1,590 Lowest | 400 ₹2,000 |
| 1.00 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | 2 | each | 1,554 ₹3,108 | 500 ₹1,000 Lowest |
| 1.01 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 20 | each | 50 ₹1,000 | 25 ₹500 Lowest |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 576 ₹576 Lowest | 1,000 ₹1,000 |
| 1.01 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 1,240 ₹1,240 Lowest | 2,400 ₹2,400 |
| 1.01 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | 1 | each | 3,237 ₹3,237 | 2,600 ₹2,600 Lowest |
Tender Value
₹18.0 L
EMD Value
₹45,091
Closing Date
7 Apr 2025, 6:00 pmClosed
Regional Manager, KSCC, Thtrissur
KSCC Regional Office, Thrissur
Fire lift work
2025_KSCC_756604_1
PWD/KS/TR/5760/2025_15_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
vyttila
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹45,091
9 Sept 2026
29 Mar 2025
10 Apr 2025
29 Mar 2025
7 Apr 2025
29 Mar 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1228953.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .