Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.1 L+₹52,450 (3.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹17.6 L+₹2.0 L (13.0%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹18.5 L+₹3.0 L (19.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹17.9 L
EMD Value
₹35,700
Closing Date
23 Mar 2020, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA No CWE/HILLS/EWS/51 of 2019-20REPAIR/MAINTANANCE OF HT CABLE CONDUCTOR WITH TRANSFORMER VOLTAGE STABILIZER AND ALLIED ACCESSORIES UNDER GE 871 EWS
2020_MES_325546_1
CA No CWE/HILLS/EWS/51 of 2019-20
Open Tender
Electrical and Maintenance Works
Works
120 days
Joshimath
CLASS E
11 documents required · 11 mandatory
₹500
Yes
GE 871 EWS
₹35,700
Yes
19 Jun 2020
15 Feb 2020
25 Mar 2020
15 Feb 2020
23 Mar 2020
2 Mar 2020
16 Feb 2020 - 27 Feb 2020
Amount
Taking down old and unserviceable transformer at diffrent locations in the area of responsibility falls under GE 871 EWS from two pole structure/foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location & connecting electrically and commissionig complete all as specified and directed at site of following capacity of transformer:- (a) 63 KVA to 100 KVA Note : - (i) The contractor will take down and refix the transformer at site located at various location as directed by Engineer-in-Charge. (ii) The rate deemed to including transportation of T&P complete. (iii) Supply only spare parts shall be measured and paid separately under respective items.
All as per item No. 1 above but capacity of transformer 160 KVA to 200 KVA
All as per item No. 1 above but capacity of transformer 250 KVA to 315 KVA
Supply only for in replacement of burnt defective HT/LT copper coil of different type capacity winding with superior quality enamelled copper winding wire/strips of approved make of suitable size/guage and number of turns matching with the existing impendence and insulated including all allied materials such as cork sheet, fiber glass insulation/paper insulation/Lathoride paper, cotton, empire tape and wooden blocks, bolts, nuts & washers (Brass) soldering/welding and other packing material etc required for entire winding of coils complete all as specified and directed.
Supply only for in replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber oil seal for transformer of capacity 63 KVA to 100 KVA of any make/type complete all as specified and directed.
All as per item No. 3 above but capacity of transformer 160 KVA to 200 KVA
All as per item No. 3 above but capacity of transformer 250 KVA to 315 KVA
Supply only for in replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber oil seal for transformer of capacity 63 KVA to 100 KVA of any make/type complete all as specified and directed.
All as item No 4 above but capacity of transformer 160 KVA to 200 KVA
All as item No 4 above but capacity of transformer 250 KVA to 315 KVA
Supply only for in replacement of gasket sheet made out of 3.15 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer of any capcity complete all as specified and directed.
Supply only for in replacement of breather assembly CI body of standard size filled with silica -gel for transformer of capacity 63 KVA to 100 KVA of any make/type complete all as specified and directed.
All as item No 6 above but capacity of transformer 160 KVA to 200 KVA
All as item No 6 above but capacity of transformer 250 KVA to 315 KVA
Supply only for in replacement of temperature gauge circular dia type of standard size for transformer of capacity 63 KVA to 100 KVA of any make/type complete all as specified and directed.
All as item No 7 above but capacity of transformer 160 KVA to 200 KVA
All as item No 7 above but capacity of transformer 250 KVA to 315 KVA
Material and labour for filling in with new transformer oil for top up having low viscosity, of approved make as per IS 355 of 1992 and di-electric strength 40 KV (after filtration) complete all as specified and directed. Make : Castrol/Power/Insole/Universal
Filtration & dehydration of existing transformer oil with machine including heating continously to achive results for reuse as per standards including recording its viscosity etc prior & after filtration & dehydration of transformer oil with maintaining its results (approve by GE) complete all as specified and directed.
Taking down old unsrviceable servo voltage stabilizer 15 to 30 KVA, 280 to 480 V oil cooled un balanced or balanced servo control from different locations in the area of responsiblity falls under area of GE 871 EWS and shifting to authorised workshop and getting back after repair/overhauling by way of replacing unserviceable parts and refixing the same at original location & connecting electrically and commissioning complete all as specified and directed. (Repair shall be carried out in authorised workshop, the rate deemed to including transportation of T&P complete). Note:- Supply only spare parts shall be measured and paid separately under respective items.
Supply only for in replacement of servo control motor for voltage stabilizer of capacity 15 to 30 KVA with base plate, condenser, capacitor etc of existing make complete all as specified and directed.
Supply only of auto control unit suitable for fitting to voltage stabliizer of capacity 15 to 30 KVA complete all as specified and directed.
Supply only of carbon bushes suitable for fitting to voltage stabilizer of capacity 15 to 30 KVA complete all as specified and directed
Supply only of main transformer coil for the voltage stabilizer of capacity 15 to 30 KVA complete all as specified and directed
Supply only of dimmer coil 25 to 45 Amps capacity complete all as specified and directed
Supply only of brass bushes and stud suitable for 15 to 30 KVA voltage stabilizer complete all as specified and directed
Taking down old unserviceable servo voltage stabilizer 75 to 100 KVA, 280 to 480 V oil cooled un balanced or balanced servo control from different locations in the area of responsiblity falls under area of GE 871 EWS and shifting to authorised workshop and getting back after repair/overhauling by way of replacing unserviceable parts and refixing the same at original location & connecting electrically and commissioning complete all as specified and directed. (Repair shall be carried out in authorised workshop, the rate deemed to including transportation of T&P complete). Note:- Supply only spare parts shall be measured and paid separately under respective items.
Supply only of servo control motor for voltage stabilizer of capacity 75 to 100 KVA with base plate, condenser, capacitor etc of existing make complete all as specified and directed.
Supply only of auto control unit suitable for fitting to voltage stabliizer of capacity 75 to 100 KVA complete all as specified and directed.
Supply only of carbon bushes suitable for fitting to voltage stabilizer of capacity 75 to 100 KVA complete all as specified and directed
Supply only of main transformer coil for the voltage stabilizer of capacity 75 to 100 KVA complete all as specified and directed
Supply only of dimmer coil 110 to 140 Amps capacity complete all as specified and directed
Supply only of brass bushes suitable for 75 to 100 KVA voltage stabilizer complete all as specified and directed
Taking down old unserviceable servo voltage stabilizer 160 to 200 KVA, 280 to 480 V oil cooled un balanced or balanced servo control from different locations in the area of responsiblity falls under area of GE 871 EWS and shifting to authorised workshop and getting back after repair/overhauling by way of replacing unserviceable parts (parts to be measured & paid under relevent items here-in-after as under) and refixing the same at original location & connecting electrically and commissioning complete all as specified and directed. (Repair shall be carried out in authorised workshop, the rate deemed to including transportation of T&P complete). Note:- Supply only spare parts shall be measured and paid separately under respective items.
Supply only of servo control motor capacity for 160 to 200 KVA voltage stabilizer with base plate, condenser, capacitor etc of existing make complete all as specified and directed.
Supply only of auto control unit suitable for fitting to voltage stabilizer 160 to 200 KVA complete all as specified and directed.
Supply only of carbon bushes suitable for fitting to voltage stabilizer 160 to 200 KVAcomplete all as specified and directed.
Supply only of main transformer coil for unbalanced type voltage stabilizer of the capacity 160 to 200 KVA complete all as specified and directed.
Supply only of dimmer coil for 225 to 285 Amp capacity complete all as specified and directed.
Supply only of brass bushes and stud suitable for 160 to 200 KVA voltage stabilizer complete all as specified and directed.
S & F in repairs Aluminium thimbles for cable connections of size 25 Sqmm to 35 sqmm complete all as specified and directed.
S & F in repairs Aluminium thimbles for cable connections of size 50 Sqmm to 70 sqmm complete all as specified and directed.
S & F in repairs Aluminium thimbles for cable connections of size 95 Sqmm to 120 sqmm complete all as specified and directed.
S & F in repairs Aluminium thimbles for cable connections of size 150 Sqmm to 185 sqmm complete all as specified and directed.
S & F in repairs Digital/Analog type ammeter with 1.0 accuracy class (+)1% of full scale 1 count 0 to 300 Amps, stranded voltage burden 0.25 VA MAX/Phase working on AC auxillary supply voltage 230 volts, Sencing CT 5 Amps flush mounted type of size 96mm x 96mm x 75mm complete all as specified and directed.
S&F in repairs Digital/Analog type voltmeter to measure AC voltage 0 to 500 Volts with 1.0 accuracy class, stranded voltage burden 0.25 VA MAX/Phase working on AC auxillary supply voltage 230 volts, flush mounted type of size 96mm x 96mm x 75mm in repairs complete all as specified and directed.
Taking down old unserviceable Indicator, any type, any colour and supply & fixing new Indicator red/yellow/green including making electrical connection with suitable size of copper lugs duly crimped complete all as specified and directed.
M&L for repairing the GOD mechanism pipe and handle lever, etc. by way of welding, greasing and including supply and fixing of new male and female contact complete all as specified and directed
Supply and fixing in repairs lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, suitable for 11000 Volts complete all as specified and directed. Make : BHEL/Areva/GE
Supply and replacement HT 11 KV outdoor type gang operated air break switch and insulator and steel frame outdoor type suitable for horizontal/vertical insulation single break provided with locking arrangement consisting of MS channel HT post type insulator copper alloys high pressure assembly opening rod of 25mm dia GI pipe medium grade complete conforming to IS-1318 of 1972 rated voltage 11 KV and current rating 200 Amps, 12 insulators, complete all as specified and directed. Make: BHEL/Jaipuria Brothers/MEI/Rashtriya.
M&L in repairs, Anti-climbing device, spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L in repairs disc type insulators, porcelain vitreous white brown or green, 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 11000 Volts complete all as specified and directed.
Supply and fixing in repairs pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line complete all as specified and directed.
Supply and fixing in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supply and fixing in repairs cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
Supply and fixing in repairs cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
M&L for painting of transformer/voltage stabilizer any make/any size including XPM wire mesh complete, by spraying with two coats of synthetic enamel paint of first quality dark grey/ivory colour paint over a coat of red oxide primer after and including complete removal of old paint and primer by scratching, rubbing and marking SM No complete all as specified and directed.
M&L for painting steel tubular pole including cross arms, street light brackets, 'D' clamps, nuts, bolts & GOD complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
Supply, fixing, connecting and testing in repairs of MCCBs in existing LT panel box / feeder pillar boxes (KIOSK) of capacity 630 Amps, 4 pole breaking capacity 50 KA adjustable type with thermal as well as magnetic balance adjustable type complete all as specified and directed. Make : L&T/SCHENIDER/LEGRAND/Havells/ABB
All as per item NO. 31 above but 400 Amps and 36 KA complete all as specified and directed Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
All as per item NO. 31 above but 350 Amps and 36 KA complete all as specified and directed Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
All as per Item No 31 above but 250 Amps and 36 KA complete all as specified and directed Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
All as per Item No 31 above but 200 Amps and 36 KA complete all as specified and directed Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
All as per Item No 31 above but 160 Amps and 25 KA complete all as specified and directed Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
All as per Item No 31 above but 25 to 100 Amps, 3 Pole,16 KA complete all as specified and directed. Make : L&T/SCHENIDER/ LEGRAND/ Havells/ABB
Supply and Replacement in repair of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed.
Supply and Replacement in repair of Earthing complete for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized wire 4.00 mm as earthing lead by means with GI pipe light grade, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering GI pipe 20mm light grade and 40mm dia GI pipe light grade for GI wire protected steel with funnel as shown in electric pate No. 3 of SSR Part I (2009) all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed.
Dismantling of ACSR/AAC conductor complete and supply and fixing aluminium conductor steel reinforced (ACSR) of size 6/1 x 3.35 (Aluminium) 1/1 x 3.35 (Steel) Rabbit as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed.
Dismantling old unserviceable XLPL cable and Supply, laying in trenches, testing and commisioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts earth grade having cross sectional area 95 Sqmm 3 core complete all as specified and directed. Make:- Havells/Polycab/Universal/Gloster
Supply and laying GI steel tube "light grade" of 80mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete all as specified and directed. Make : TATA/Jindal/Advance Steel Tubes
Taking out old unserviceable rubber matting and supply and laying new rubber matting (chequred type), 11000 volts grade of size 2m x 1m x 19 mm complete all as specified and directed.
Dismantling concrete poles/struts, any size complete all as specified and directed.
Supply and erecting in true vertical steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. Make:- Jindal Steel/National Tubing Co. Kanpur/Bharat Conduit (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work).
M&L stay assembly complete with accessories i.e. stay plate 300mm x 300mm x 6mm, galvanised thimbles, GI stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 of MES Schedule Part-I (2009) complete including dismantling of stay assembly complete all as specified and directed. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid separately.
Supply and Replacement in repair of Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete including dismantling and taking down old cross arms, bracings, supports, clamps, etc. complete all as specified and directed.
M& L for Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 4mm dia including dismantling and taking down old Cradles, complete all as specified and directed.
M& L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size Complete all as specified and directed.
Trimming tree branches coming in proximity to HT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 1.5 Mtrs apart from ACSR conductor from all sides all as directed. (Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost ). Note:- Five lines together will be measured as one span from pole to pole Complete all as specified and directed.
Re-streching of loose over head ACSR conductor/AB Cables/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire. Old conductor shall be reused where required for repairing broken length of conductor complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5 m in depth bur not exc. 3.0 m for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
Supply and laying Sand cushioning for the purpose of floors and laying of cables including watering and consiolidation complete all as specified and directed.
Supply and laying Reinforcecd precast concrete cable cover, class HV, type1, flat, size 300mm x 180mm x 40mm laid in trenches flat complete all as specified and directed.
M&L for PCC 1:3:6 (nominal mix), type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Foundation for steel tubular poles (1:4:8) Type D-2 using 40 mm graded aggregate for foundation of poles including necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
Coping for steel tubular poles (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
M&L for calibration (All connections and mechanism) cleaning, servicing, overhauling, testing complete of 11KV vaccum circuit breakers respectively as mentioned below :- (a) Taking out incoming and outgoing HT 11 KV 3 Core cables from the electric system and calibrating the CTs 03 Nos of each VCB with the help of primary injection kit and testing it for proper tripping system in presence of Engr-in-charge and reconnected the incoming and outgoing HT Cables complete of both panels. (b) Inspecting, servicing and checking all the connections of control wiring availability of proper DC supply and AC supply, incoming and outgoing connections and tightening them cleaning the contacts and terminal with CTC solution and using the blower for dusting complete testing it for satisfactory operation raising and lowering mechanism in presence of Engr-in-Charge. (c) Taking out IDMT over relay 02 Nos and earth fault relay 01 No from the 11 KV VCB (3 Nos in each) and calibraing the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge. Note : (i) All the instruments primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rates (ii) Cost of nut bolts, cleaning material, jelly/grease, carbon tetrachloride etc are included in the quoted rate.
Supply and fix in replacement of volt meter Digital type of required capacity complete all as specified and directed.
Supply and fix in replacement of Ampere meter Digital type of required capacity complete all as specified and directed.
Supply and fix in replacement of indicator lamp complete all as specified and directed.
Supply and fix in replacement of tripping coil of VCB 800 Amps capacity cmplete all as specified and directed.
Supply and fix in replacement of closing coil of VCB 800 Amps capacity cmplete all as specified and directed.
S & F of cable route indicator or cable joint mark for 11000 volts made out of mild steel 100mm dia 6mm thick plate welded to 40 x 40 x 6mm angle iron 50 cm long embeded in PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) block of size of 150mm x 200mm x 200mm including applying two coats of synthetic enamel paint over a coat of redoxide primer on steel surfaces complete all as specified and directed.
Amit Engineering
Bedi Refrigeration Works
SEEMA ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .