Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC MANOBAL 236 VARDMAN NAGAR SHOBAWATO KI DHANI PAL ROAD JODHPUR | ₹24.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹28.0 L+₹3.8 L (15.8%)Rejected-AOC HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | ₹28.0 L+₹3.8 L (15.8%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹28.4 L+₹4.2 L (17.3%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹28.4 L+₹4.2 L (17.3%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹29.0 L+₹4.8 L (19.9%)Rejected-AOC | ₹29.0 L+₹4.8 L (19.9%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹29.3 L+₹5.2 L (21.4%)Rejected-AOC | ₹29.3 L+₹5.2 L (21.4%) | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No. 2 Jodhpur AFS Jodhpur
Repair to sanitary fittings, CP fittings, tilling, Plastering, GI fittings and other misc BR works at bundela enclave, MES Colony, Dilbag enclave under AGE BR-II at GE (AF) No. 2 Jodhpur
2024_MES_667125_1
8472/E8
Open Tender
Construction Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹70,000
Yes
14 Oct 2024
20 Jul 2024
16 Sept 2024
20 Jul 2024
13 Sept 2024
5 Aug 2024
27 Jul 2024 - 3 Aug 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises as directed by Engineer-in-Charge
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 as directed by Engineer-in-Charge
M&L for glazed ceramic tiles, coloured, 450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces as directed by Engineer-in-Charge.
M&L for light coloured vitrfifed cermaic tiles 10 mm thick area of each tiles not less than 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6 as directed by Engineer-in-Charge
All as per item no.4.00 above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfacesas directed by Engineer-in-Charge
M&L for machine cut kota stone slab flooring 20 -25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigmenst to match the shade of the slab including rubbing and polishing complete including 15 mm screed bed or bedding layer in cement mortar 1:6 as directed by Engineer-in-Charge
M&L for kota-stone slab 15 mm thick in riser of steps skirting dado skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfaces as directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each or as directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each as directed by Engineer-in-Charge)
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site to store complete as directed by Engineer-in-Charge.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site to store complete.
Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipe, jointed in cemented mortar and taking out of trenches or in vertical position of internal dia 100 mm & less all as directed by the Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Demolition of cement concrete (reinforced) in any position not otherwise specifically provided for and removing from site all as specified and directed.
S&F 30 mm thick factory made , second class hard wood flush shutters ,solid core constructions with block board core and plywood face panels, commercial type on both face directed by Engineer-in-Charge
S&F 35 mm thick factory made , second class hard wood and skeleton shutters open rebated and prepared to receive glass gauze etc (without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) supplied and fitted to chowkats as directed by Engineer-in-Charge
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, as directed by Engineer-in-Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing as directed by Engineer-in-Charge
S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed as directed by Engineer-in-Charge
S&F 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts and sliding bolts of extruded sections or casr aluminium alloy as directed by Engineer-in-Charge
S&F for 100 mm long butt hinges, medium weight stainless steel as directed by Engineer-in-Charge
S&F aluminium handles, cast type, anodized, of size 150mm as directed by Engineer-in-Charge.
S&F galvanised steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair 300 mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete as directed by Engineer-in-Charge.
S&F in repairs, 100 mm length door stopper aluminum alloy body and tongue, anodized, with hard drawn steel spring, complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each as directed by Engineer-in-Charge
S&F in repairs aluminium handles, cast type, anodized, of size 150mm as directed by Engineer-in-Charge.
S&F in repairs 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts and sliding bolts of extruded sections or cast aluminium alloy
S&F in repairs 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed as directed by Engineer-in-Charge.
Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mm all as specified and directed by Engr-in-charge
S&F in repair galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples as directed by Engineer-in-Charge
S&F curtain rod, stainless steel chromium plated with fixing brackets stops roller etc of 25mm bore complete all as specified and directed.
S&F stainless steel decorative end cap suitable for 25mm dia curtain rod complete all as specified and directed.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones as directed by Engineer-in-Charge.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square n.exc. 0.5 sqm in each pane as directed by Engineer-in-Charge.
S&F in repairs 15 mm bore bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule as directed by Engineer-in-Charge.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup , screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions as directed by Engineer-in-Charge.
S&F 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions as directed by Engineer-in-Charge.
S&F in repair brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union as directed by Engineer-in-Charge.
S&F in repairs brass chromium plated health faucet of 15 mm bore complete as directed by Engineer-in-Charge.
S&F in repairs PVC connection 15 mm size with nuts of length 450 mm as directed by Engineer-in-Charge.
S&F in repairs stainless steel toilet paper holder fixed to walls with chromium plated (CP) brass screws all as directed by Engr-in-charge
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe PVC connection 15 mm size with nuts of length 450 mm.complete all as specified and as directed by Engineer-in-Charge
S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified and as directed by Engineer-in-Charge
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish and as directed by Engineer-in-Charge.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets all as directed by Engr-in-charge.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete.
Disconnecting existing tanks of any description exc. 250 ltrs and n.exc. 500 ltrs capacity and removing from site complete all as specified and as directed.
Disconnecting existing tanks of any description exc. 500 ltrs and n.exc. 1000 ltrs capacity and removing from site complete all as specified and as directed.
Disconnecting existing tanks, exc. 250 ltrs and n.exc. 500 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. And hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. Measured separately) complete all as specified and as directed.
Disconnecting existing tanks, exc. 500 ltrs and n.exc. 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. And hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. Measured separately) complete all as specified and as directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
Supplying and laying of CPVC pipes 16mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply and fix 16mm outer dia CPVC brass elbow complete all as specified and directed
Supply and fix 16mm outer dia CPVC UNION complete all as specified and directed
Supply and fix 16mm outer dia CPVC Male brass threaded adaptor (MTA/MBTA) complete all as specified and directed
Supply and fix 16mm outer dia CPVC Female brass threaded adaptor (FTA/MBTA) complete all as specified and directed
S&F in repairs, glass corner shelf of fixed with and including chromium plated brass screws and cleats complete all as specified and directed.
S&F in repairs, 15mm bore Bib tap standard of PTMT(Minimum weight 90 gms) any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. Make: Prayag or equivalent as approved.
S&F 2000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layer (ISI marked) complete all as specified and directed.
Dismantling exc 1000 and not exc 2000 ltrs capacity water tanksand removing to store complete all as specified and directed
S&F in repairs, 1000 to 1400 mm long and 20 mm wide door seal incl 10 mm wide cotton complete all as specified and directed .
S&F in repairs, 18/19 mm thick prelaminated particle boards, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work complete all as specified and directed.
S&F in repairs, aluminium (extruded section) body door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F in repairs, brass chromium plated towel ring 200mm dia complete all as specified and directed.
S&F in repairs, continuous piano hinges, mild steel, bright finish or electro galvanised 30mm width of flaps (when open) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially sunkun floor provided for complete all as specified and directed
M&L for plain cement conrete 1:5:10 type E-2 (using 20 mm graded broken bricks aggregate ) as in sunken/foundation and mass concrete complet all as specified and as directed by Engineer-in-Charge
M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specifiaction:-(i) Cleaning of sunken floor surface with mechanical means i.e wire brush/air blower etc and remove all loose/unsound material dirt dust etc. (ii)Applying cement slurry mixed with acrylic based polymer modified cementious composite compund coating Hydroproof Xtra of FOSROC /Equivalent of Dr Fixit of Pidilite industries Ltd in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four partof cement) (iiii) First layer of cement slurry @0.444 kg /sqm mixed with acrylic based modified cementious composite compund @0.222 litre/sqm and allow it to air dry for 4 hour. (iv) Second layer of cement slurry @0.222 kg /sqm mixed with acrylic based dified cementious composite compound @0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polytgen film shall be pasted with help of adhesive over treatment . Note:- Joints of WC/Trap/Soil waste shall be prperly sealed with sealing compund . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Taking down cement plaster in brick walls,stone wall,ceiling of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M& L for 15 mm thick rendering on block masony or concrete surfaces in CM 1:4 on external walls at height upto 12.0mtr from ground level, finished even and smooth without using extra cement complete all as specified.Note:- Necessary formwork required will not paid seperatly.
M& L for 15 mm thick rendering on block masony or concrete surfaces in CM 1:6 on internal walls at any height, finished even and smooth without using extra cement and all as specified.
M& L for 10 mm thick rendering on ceiling surfaces in CM 1:3 on finished even and smooth without using extra cement and all as specified.
Supply only integral water proofing compound.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer, white or tinted, upto 20 m height from ground leven all as directed.
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint upto 12.00 m height from ground leven all as directed.Note:- Necessary formwork required will not paid seperatly.
M&L for preparation of old ceiling surface and applying one coats of white washover and , all as directed.
M&L for preparation of new plastered or unplastered surfaces of ceilings and applying two coats of white wash over and , all as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment/preparation of old surface of walls and applying two coats of oil bound distemper over a layer wall care putty, all as directed.
R B Infrabuilders (BID ID -3095706)
KRISHNA CONSTRUCTION COMPANY (BID ID -3094972)
POOJA CONSTRUCTION (BID ID -3083166)
M/s RKG CONSTRUCTIONS (BID ID -3088063)
Bansal Enterprises (BID ID -3083885)
JAMWAY MATA CONSTRUCTION COMPANY (BID ID -3086265)
GANGADHAN ENTERPRISES (BID ID -3085442)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .