| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC F 6 RACE COURSE OPP CENTRAL BANK OF INDIA DEHRADUN 248001 UTTARAKHAND | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹5.6 L Quoted ₹5.8 L | L1 | Accepted-AOC L1 Lowest Reasonable Rate |
| 2 | L2₹6.5 L+₹66,274.50 (11.4%)Rejected-Finance | ₹6.5 L+₹66,274.50 (11.4%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹7.0 L+₹1.2 L (20.1%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹7.0 L+₹1.2 L (20.1%) | L3 | Rejected-Finance 3RD LOWEST |
| 4 | L4₹70.5 L+₹64.7 L (1115.6%)Rejected-Finance LA 35 ROYAL PARK PALLAVPURAM PHASE I MEERUT UTTAR PRADESH 250110 | MEERUT | UTTAR PRADESH | 250110 | ₹70.5 L+₹64.7 L (1115.6%) | L4 | Rejected-Finance 4TH LOWEST |
| 5 | L5₹7.4 L+₹1.6 L (27.4%)Rejected-Finance AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | ₹7.4 L+₹1.6 L (27.4%) | L5 | Rejected-Finance 5TH LOWEST |
| Sl No | Description | Qty | Unit | TARUN ENGINEERING WORKS L3 | expertengineers L1 | S.K ASSOCIATE L5 | GLOBALVISION POWER SOLUTIONS PVT LTD L4 | trinity construction L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and opening of parts for servicing of water cooled /Air cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,ie diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil etc as required at site as per manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Srl No. 1(a) & (b) here in below)
Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc.(ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge
(iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Topping up and supply only” and shall be measured and paid separately under appropriate item of Sch . Its cost of filling is deemed to be included under the rates quoted by the contractor.
(a) 10 KVA TO 125KVA 3 Phase 50 HZ Make:Kirloskar/Kirloskar Green and existing make on site | 8 | Each Job | 5,500 ₹44,000 | 2,000 ₹16,000 | 5,000 ₹40,000 | 900 ₹7,200 Lowest | 4,000 ₹32,000 |
| 2.00 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar Green | 1 | Each Set | 6,000 ₹6,000 | 2,000 ₹2,000 | 5,000 ₹5,000 | 1,400 ₹1,400 Lowest | 5,000 ₹5,000 |
| 3.00 | Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled / fixed under Sch item No 1.00 here in above complete all as specified and directed.
(a)10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each Job | 1,100 ₹8,800 | 350 ₹2,800 Lowest | 3,000 ₹24,000 | 550 ₹4,400 | 1,200 ₹9,600 |
| 4.00 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each set | 700 ₹700 | 500 ₹500 | 3,000 ₹3,000 | 320 ₹320 Lowest | 800 ₹800 |
| 5.00 | Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch tem No 1.00 here in above complete all as specified and directed.
(a) 10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each set | 800 ₹6,400 | 500 ₹4,000 Lowest | 3,000 ₹24,000 | 550 ₹4,400 | 1,500 ₹12,000 |
| 6.00 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each set | 800 ₹800 | 600 ₹600 Lowest | 3,000 ₹3,000 | 850 ₹850 | 1,200 ₹1,200 |
| 7.00 | Supply only Air cleaner element primary and safety for following capacity of DG set dismantled/fixed under Sch item No 1.00 here in above complete all as specified and directed.
(a) 10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each | 2,500 ₹20,000 | 2,000 ₹16,000 Lowest | 3,000 ₹24,000 | 2,200 ₹17,600 | 3,500 ₹28,000 |
| 8.00 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each | 4,500 ₹4,500 | 4,000 ₹4,000 | 3,000 ₹3,000 Lowest | 6,500 ₹6,500 | 5,000 ₹5,000 |
| 9.00 | Dismantling and taking out the radiator fitted in following capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution, including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks.including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator, re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item ’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc.(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
(a) 25 KVA to 125 KVA 3 phase 50 HZ .Make- Kirloskar Green and existing make on site | 1 | Each Job | 6,500 ₹6,500 | 3,500 ₹3,500 | 5,000 ₹5,000 | 2,500 ₹2,500 Lowest | 4,000 ₹4,000 |
| 10.00 | (b) 250 KVA 3 phase 50 HZ. Make- Kirloskar Green | 1 | Each Job | 7,000 ₹7,000 | 4,500 ₹4,500 | 5,000 ₹5,000 | 3,500 ₹3,500 Lowest | 5,000 ₹5,000 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
16 May 2026, 6:00 pmClosed
AGE (i) RAIWALA
AGE (i) RAIWALA
REPAIR/ REPLACEMENT OF DG SETS AND ALLIED WORKS AT MIL STN RAIWALA UNDER AGE (I) RAIWALA
2026_MES_762392_1
8142/26-27/E8
Open Tender
Civil Works
Works
120 days
AGE (I) RAIWALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RAIWALA
₹18,000
Yes
26 Aug 2026
28 Apr 2026
18 May 2026
28 Apr 2026
16 May 2026
10 May 2026
28 Apr 2026 - 9 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and opening of parts for servicing of water cooled /Air cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,ie diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil etc as required at site as per manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Srl No. 1(a) & (b) here in below)
Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc.(ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge
(iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Topping up and supply only” and shall be measured and paid separately under appropriate item of Sch . Its cost of filling is deemed to be included under the rates quoted by the contractor.
(a) 10 KVA TO 125KVA 3 Phase 50 HZ Make:Kirloskar/Kirloskar Green and existing make on site | 8 | Each Job | - | - |
| 2 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar Green | 1 | Each Set | - | - |
| 3 | Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled / fixed under Sch item No 1.00 here in above complete all as specified and directed.
(a)10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each Job | - | - |
| 4 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each set | - | - |
| 5 | Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch tem No 1.00 here in above complete all as specified and directed.
(a) 10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each set | - | - |
| 6 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each set | - | - |
| 7 | Supply only Air cleaner element primary and safety for following capacity of DG set dismantled/fixed under Sch item No 1.00 here in above complete all as specified and directed.
(a) 10 KVA TO 125 KVA 3 Phase 50 HZ Make:Kirloskar | 8 | Each | - | - |
| 8 | (b) 250 KVA 3 Phase 50 HZ Make:Kirloskar | 1 | Each | - | - |
| 9 | Dismantling and taking out the radiator fitted in following capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution, including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks.including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator, re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item ’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc.(iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
(a) 25 KVA to 125 KVA 3 phase 50 HZ .Make- Kirloskar Green and existing make on site | 1 | Each Job | - | - |
| 10 | (b) 250 KVA 3 phase 50 HZ. Make- Kirloskar Green | 1 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8142TED.pdf
Tender Documents • 1.22 MB
MAKEAPPROVAL.pdf
Additional Documents • 15.01 MB
BOQ_854063.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .