Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC JOTANKUR TEGHORIJOTEVIRAM PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721627 | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹13.7 L+₹1.5 L (12.6%)Rejected-Finance H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹14.0 L+₹1.8 L (15.1%)Rejected-Finance 0 3 SHASTRI STREET FEROZEPUR CITY PB PIN 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹14.6 L+₹2.4 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹18.4 L
EMD Value
₹36,874
Closing Date
1 Feb 2022, 6:00 pmClosed
Garrison Engineer Ludhiana
Military Engineer Services Garrison Engineer Near Jagraon Bridge Ludhiana-141001
SPECIAL REPAIR TO BLDG NO P-28/01 TO P-28/04 OF LT AD REGT (COMP) AT DHOLEWAL MIL COMPLEX UNDER GE LUDHIANA
2022_MES_499317_1
GE/LDH-54/2021-22
Open Tender
Civil Works
Item Rate
180 days
Dholewal Cantt under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹36,874
Yes
21 Feb 2022
4 Jan 2022
3 Feb 2022
4 Jan 2022
1 Feb 2022
18 Jan 2022
4 Jan 2022 - 17 Jan 2022
Amount
Sch 'A' sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level).
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc.
Dismantling floor, hearth or wall tiles including cement mortar bedding(but not backing) and removing serviceable tiles to stores and rubbish off the premises.
Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each.
Taking down shutters of any desciption area exc 1.0 Sqm but n.exc 2.0 Sqm each and refixing in the same opening after easing and minor adjustment.
Taking down Shutters of any description area exc 1 Sqm but n.exc. 2 Sqm Each
Taking down chowkats or frames(without taking off shutters from the frame) area n.exc 1.5 Sqm each.
Hacking out old broken glass (any thickness) , size, quality or description from metal frame including punching or drilling out old glazing pins and providing and fixing new ones.
Demolition of reinforcement cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (reinforcement cut as reqd to facilitate demolition)
M&L for reinforced Cement Concrete type B1 1:1.5:3 (M20) (nominal mix ) (using 20 mm graded stone aggregate) in Beams, cantilevers, lintels etc.
M&L for reinforced Cement Concrete type B1 1:1.5:3 (M20) (nominal mix ) (using 20 mm graded stone aggregate) in Chajjas etc.
Use and waste rough finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc.
Use and waste rough finished Form work to edges of concrete floor and roofs and similar work exceeding 5 Cm but not exceeding 10 Cm wide.
S&F for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality.
M&L for 25mm thick cement concrete type B-O, 1:2:4 (20mm graded agg ) as in flooring finished even and fair.
Dismantling of stone slabs and tiles of any description or thickness in floors, approns and laid bedded and pointed in any mortar atc.
M&L for granite slab (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20 mm thick screed bed of cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite.
M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing
Ditto- all as per item No 18 above but in one piece as in treads of stair
Ditto- all as per item No 18 above but in skirting / dado laid over 10mm thick cement screed in CM 1:4
Ditto- all as per item No 18 above but in one piece as in riser of of stair
M&L for Non skid cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over 15mm thick screed bed in cement mortar (1:6) all as specified and directed.
Ditto- all as per item No 22 but in skirting/dado laid over 10mm thick cement screed in cm 1:4 complete all as specified.
M&L for glazed ceramic coloured / printed tiles (450X350mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:4
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n,exc 0.5 Sqm, each pane. Complete all as specified and directed.
S&F for sheet 4.0 mm thick frosted glass, squares exc 0.5 sq. m each pane.
M&L for 12mm thick rendering on brick work or concrete surfaces in cement mortar 1:6 finsihed the surfaces even and smooth without using extra cement.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling, Complete all as specified and directed.
M&L for 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finsihed the surfaces fair and even Complete all as specified and directed.
M&L for two coats of Oil bound distemper over a coat of chalk whiting on wall surfaces inclduing prepration of newly plastere surfaces.
M&L for three coats white wash on ceiling surfaces inclduing prepration of newly plastered and undecorated surfaces.
M&L for two coats of cement base paint including preparation of newly plastered surfaces on walls, Complete all as specified and directed
M&L for 40mm thick cemnt concrete type B-1, 1:2:4 (using 20 mm graded aggregate) as in floorings , finished even and smooth without using extra cement complete all a specified and directed laid in alternate bay.
M&L for 50mm thick PCC 1:3:6Type C-1 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement complete all as specified.
S&F for 38mm width of strip glass dividing strips, 3mm thick and inserted in position to confirm to design.
S&F for solid PVC door frame of sixe 50mmx47mm made out of 5mm wood grain printed PVC Sheet reinforced with MS square tube in opening as per specification and drawing.
S&F for factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded wood grain printed PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm used instead of exposed portion of PVC sheet beading as per specification and drawing.
S&F for pressed steel frames,size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete ,as specified.
S&F for pressed steel frames,size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete ,as specified.
M& L for providing cement concrete type C-0 1:3:6 (12.5 mm graded agg) as for pressed steel chowkhats.
S&F for 2nd class 35mm thick hard wood,Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces, and fitted to chowkats.
S&F for 35mm thick first class hard wood Glazed and skelton door shutters , open rebated and prepare to receive glass, gauge etc, size of members of shutters as specifed in SSR part I
M&L for two coats of synthetic enamel painting on wooden surfaces over a coat of pink primer including prepration of newly untreates surfaces.
M&L for box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F for box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F for box type steel ventilator side/top hung with glazing bars dovetailed or welded and treated with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07.
S&F for mild steel framed work such as grills, framed guard bars, grating and like confirming to FE 410 or FE 310
M&L for painting two coats of synthetic enamel paint including preparation of new steel surfaces of any description over 10cm in width or grith not other wise described. Complete all as specified and directed.
S&F for 150mm aluminium anodised barrel tower bolts of extruded section and fixed.
S&F for 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F for butt hinges, 100mm medium weight, cold rolled mild steel.
S&F for 125mm aluminium handles, cast type , anodised.
S&F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm
S&Ffor galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in repair.
S&F in repair door helical spring mild steel 300mm, ordinary rat tail rod patteren including roller and roller plate complete.
Dismantling brick work or stone/boulder masonary, built in cement mortar or cement lime mortrar incl all qupins, arches, pillars, etc,but incl. ashlar fencings, dressed stone works and precast concrete articles
M&L for brick work with sub class B brick straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 all as specified and directed.
Ditto- all as per item No 57 but except bricks
Taking down eaves gutter and rain water pipes (of any size and patern), incl all fittings and, heads, shoes, bends, swan-necks, etc incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accesaries)
S&F for 110mm bore PVC (SWR) soil, waste and vent pipe, in any length , with rubber joints, laid in trenches or in floors
S&F for PVC (SWR) 110mm dia bend of any radius.
S&F for 18/19mm block boards grade two, interior grade, commercial type with decorative face veneer on both faces and fixed to timber frame work with screws complete all as specified.
Demolition of mud in roofs, any thickness, incl plastering and leeping (whether full thickness removed or only part thereof)
Dismantling of brick tiles laid on mud mortar and jointed and pointed in any cement mortar
M&L for PCC( 1:3:6 ) type C-2 using 20mm graded stone as in padding on roof correction of slope all as spfd
M&L for 15mm thick rendering on terrace, sides of parapet in cement mortar 1:4 with water proofing compound , finished even and fair.(Note water proofing compound will be measured and paid separately under other item.
Supply only integral water proofing compound.
M&L for cleaning the new plastered surfaces with wire brushes, brooms etc and applying a priming coat of bitumen primer @ 0.30 ltrs/Sqm consisting of 3/4 part bitumen of grade 85/25 and 1/4 part of kerosene oil.
M&L for providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/Sqm ) land on after applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2Kg per Sqm by forced application complete all as specified.
M&L for applying a coat of industrial bitumen 85/25 at the rate of 1.2Kg per sqm with forced application above APP based polymeric membrance
M&L for 40mm thick brick tiles laid on 15mm thick cement mortar 1:6 and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement
Ditto- all as per item No 71 but except tiles after clening and removing old mortar from bricks.
M&L for flush pointing to brick laid flat or brick tiles in paving cement mortar in 1:3 complete all as specified.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, benching rounded or chamfered on edges complete.
M&L for PCC 1:5:10 type E-2 using 40mm graded brick aggregate as filling under (sunken slab) floors complete all as specified.
S&F for 20mm bore Brass ball valve with polythene float and fly nut fixed in repairs
S&F for stop valves 20mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle etc complete fixed in repairs.
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store.'
Ditto- all as per item No 78 above but 20 mm bore.
S&F for 15mm GI tubes, medicum grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors.
Ditto- all as per item No 80 above but 20mm bore.
Refixing old steel tubing and connections in new or old postion (wall, ceiling , floors ,etc) 15mm bore.
Ditto- all as per item No 82 above but 20mm bore.
S&F for PVC valve less, syphonic action type low level flushing cistern of capacity 10 Ltrs with inlet, ball valve, float and handle and fixed to IWC on existing brackets, fixed in repairs.
S&F in repair vitreous china washbasin, white, flat back, size 550 x 400mm, including brackets & incl 32mm bore waste fitting brass, CP for glazed ware basinetc with long screwed shanks and fly-nuts flange end bedded in red lead cement and other end fixed.
S&F for viterous china squartting pan orrisa pattern , size 580x 440mm white, interged foot rest including connection to trap and to flush pipe, anti syphonic pipe etc complete making good to floor.
S&F for soap dish, any type, fixed to plugs with chromium plated brass screws in repair complete all as specified.
S&F for fancy type pillar taps 15 mm bore cast copper alloy with capstan heads chromium plated ,scrwed down high pressure, with or without lettered hot or cold with long scrwed shanks and fly nuts-nuts scrwed for iron pipe and fixed in repair complete all as per specified.
S & F for fancy type bib tap of 15 mm bore cast copper alloy chromium plated with crutch or butterfly handle ,screwed down, scrwed for iron pipe or for brass ferrule and fixed in repair complete all as per specified.
S&F for 15mm bore stop valve/angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles fixed in repairs.
S&F for chromium plated shower roses with or without swivel join ts 100mm size incl fixing to steel pipe all as per directed .
S&F for 15mm stop cock cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated with long shank and cup (concealed type), complete all as specified.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia D-type, 60cm long between flange.
S&F in repair PVC bathroom cabinet mirror size 350mm x 450mm all as specified & directed by Engineer-in- charge
S&F for PVC connections 15mm size with PTMT nuts of lenth 450mm
Supply & fixing for glass self assembly with stainless steel frame Corner glass shelf etc complete all as specified & directed by Engineer-in-charge.
Dismantling water tank & removing to store of capacity exc 250 and n exc 500 Ltr
S&F in repairs Rotational moulded polythylene water strarge tanks 500 ltr (Cylinderical vertical with closed top ) hoisted and fiexed in position all as per specified in SSR Pt-1.
Taking down eaves gutters and rainwater pipes (any size or pattern), Cast iron said, waste and vent pipes including all fittings,heads, shoes, bends, swan-necks, etc. all as speicified and directed by Engineer in Charge
S&F for 100mm bore cast iron soil, waste and vent pipe, in any length with or without ears, with cement joints, laid in trenches or in floors.
S&F for 75mm bore CI branch pieces with oval access door, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches.
S&F for 75mm bore cast iron soil, waste and vent pipe, in any length with or without ears, with cement joints, laid in trenches or in floors.
S&F for 75mm bore cast iron cowls.
S&F for CI floor traps 75mm bore and jointing to waste pipe in cement concrete 1:2:4 type B-1.
M&L for Endura chequered cement concrete tiles 30cmx 30cmx 10mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6
Taking down curatain rods along with wooden pallmate laid on wall.
S&F in repair curtain rod made out of 25mm dia(outer dia )pipe having thickness 0.63mm , PVC coated and colour/pattern, over all dia 28 to 29 mm complete all as specified and directed, Make :- Aerolux/MEC.
S&F for plastic finial of 28 to 29mm bore, decorated type, of any colour/pattern, best quality to suit the curtain rod and fixed at the end of curtain rod with suitable adhesive complete all as specified and directed, Make:- Aerolux/MEC or VISTA
S&F for mild steel prepainted bracket to hold the curtain rod and fixed to wall(Concrete/brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the disturbed surfaces complete all as specified and directed.
M&L for one coats white wash on wall undecorated surfaces including prepration of Old plastered surfaces.
M&L for One coats white wash on ceiling undecorated surfaces including prepration surface, plastered or un plastered of Old undecorated surfaces.
M&L for one coat of oil bound distemper to old surfaces of walls after preparation complete all as specified.
M&L for one coat of cement base paint to old surfaces of walls after prepration complete all as specified.
S&F in repairs stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen or laboratory, with plug, waste pipe, washers incl. cantiliver cast iron brackets, connecting union etc overall size 915mm X 460mm with bowl size 410mm X 330mm X 160mm.
S&F in repairs stainless steel kitchen plate rack fixed in wall having overall size 600mm X 750mmX 250mm complete. ( Cat No.P-330: Make Prayag or equivalent)
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
Taking down Ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Refixing only ceiling fan and connecting up including provision sutiable of new down rod for ceiling fans,of cable from celling rose/ connector to fan incl painting all as specified and as directed.
Taking down Exhaust fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Refixing only exhaust fan and connecting up including provision of cable from celling rose/ connector to fan incl painting all as specified and as directed.
M &L for point wiring with PVC FRLS insulated and PVC sheathed cable with copper conductor single core size of 1.5 sqmm in and including heavy duty PVC conduit ISI marked in concealed in walls, ceiling etc, for one light / fan / bell point controlled by one switch including replacing exisiting switch boards/boxes with new MS concealed terminal boxes with 3mm plastic laminated sheet top cover,earth contiunity wire PVC insulated sheathed 1.5 sqmm solid copper conductor cable connected to common earth dolly all as specified. :-
One light/fan/call bell point controlled by one, one way switch
One switch socket outlet point 5 Amps on independent board
One 3 Pin socket outlet , 5 Amps on the same board with other switch
One light point controlled by two 2-way switches, with cables 1.5 sq. mm size
All as per item No. 121 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix for LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix for LED tube light fittings 600 mm, 10W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix for bulk head fittings 10W, 240V, 50Hz,rated input current- 0.070-0.110, oprating voltage range- 140-270, P.F- not less then 0.95, LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix for LED 10 Watt, B-22 type complete all as specified and directed.
Supply and fix for lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent fittings type complete all as specified and directed.
M & L for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed. Note:- Three run of cable shall be measured in one unit.
Supply and fix for TV Socket complete all as specified and directed.
Supply and fix for SPN MCB DB 12 ways with 200 Amps rated bus bar 240Volt, Double door type all as specified
Supply and fixing for MCB SPN 32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed.
Supply and fixing for MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed
Supply and fix for ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and as directed
Supply and Fix for Switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed.
Supply and Fix for Socket outlet 3 pin, 5 A flush Piano,Flush type complete all as specified and as directed.
Supply and Fix for switch Socket combenation 2 in 1 outlet 3 pin, 5 A flush type complete all as specified and as directed by Engr-in-charge
Supply and Fix Switch for socket combenation 2 in 1 outlet 3 pin, 16 A flush type complete all as specified and as directed.
S&F for fan regulator , flush stapped type ,electronic ,230 Volt, complete all as specified and directed
Supply and fix for Buzzer , ding dong AC 230 Volt single pole complete all as specified and as directed .
Supply and fix for bell push flush type 5 Amp, complete all as specified and as directed .
M &L for Earthing including excavation complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 4 core complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
M & L for Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M & L for Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. Note:- The punning down thickness shall be measured in 18 cm.
M & L for Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified
Taking down of any size of bldy security light fittings complete all as specified and directed.
Supply and fixing for bldg security light fitting LED 30 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, oprating range- 90V to 340V AC. LED life -1 Lac burning hrs , fixture should with stand 320V upto 48 Hrs , auto cut off>320 V & restart ,440V sustain upto 8 Hrs, NABL acreddited LM 79 report, IP66 with high power LED lamp incl with suitable size of bracket compete all as specified and directed. Make :- Crompton/ Havells/Halonix/ Polycab/everday
ANUJ ABROL CONTRACTOR
Marwaha Builders
JAY ANN CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .