Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹6.0 Cr+₹19.5 L (3.34%)Rejected-AOC | ₹6.0 Cr+₹19.5 L (3.34%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹6.9 Cr+₹1.1 Cr (18.3%)Rejected-AOC LINK FIRST NEW AIRPORT ROAD NEAR TATA ENGINEERING GARAGE PO HUMAMA SRINAGAR 190014 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | ₹6.9 Cr+₹1.1 Cr (18.3%) | L3 | Rejected-AOC Not lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | M/S SHAH CONSTRUCTION L3 | M/s Muzaffar Ahmad Mir L2 | M/S MANZOOR AHMAD YATOO L1 |
|---|---|---|---|---|---|---|
| 1.00Note: (i) Please refer Schedule 'A' Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii) This Schedule 'A' Part-XI to XIV is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidder, the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained. | ||||||
| 2.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | ||||||
| 2.01 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. | 1 | Each | 1,91,00,000 ₹1,91,00,000 | 1,47,77,777 ₹1,47,77,777 | 1,27,00,000 ₹1,27,00,000 Lowest |
| 2.02 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II. | 1 | Each | 4,50,000 ₹4,50,000 | 4,65,777 ₹4,65,777 | 4,19,000 ₹4,19,000 Lowest |
| 2.03 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-III. | 1 | Each | 19,00,000 ₹19,00,000 | 17,77,777 ₹17,77,777 | 16,00,000 ₹16,00,000 Lowest |
| 2.04 | Lump sum price worked out by the contractor for ROAD/ PATH/ HARD STANDING AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. | 1 | Each | 2,05,00,000 ₹2,05,00,000 | 1,65,43,879 ₹1,65,43,879 Lowest | 1,76,38,000 ₹1,76,38,000 |
| 2.05 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-V. | 1 | Each | 5,00,000 ₹5,00,000 | 3,97,777 ₹3,97,777 | 3,00,000 ₹3,00,000 Lowest |
| 2.06 | Lump sum price worked out by the contractor for RETAINING WALL WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. | 1 | Each | 25,00,000 ₹25,00,000 | 23,99,997 ₹23,99,997 | 20,00,000 ₹20,00,000 Lowest |
| 2.07 | Lump sum price worked out by the contractor for FENCING, SECURITY WALL AND GATE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. | 1 | Each | 1,70,00,000 ₹1,70,00,000 | 1,69,99,999 ₹1,69,99,999 Lowest | 1,70,00,000 ₹1,70,00,000 |
| 2.08 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. | 1 | Each | 8,00,000 ₹8,00,000 | 7,99,999 ₹7,99,999 | 7,50,000 ₹7,50,000 Lowest |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
26 Sept 2025, 6:00 pmClosed
CE 31 Srinagar Zone
HQ CE 31 Srinagar Zone
PROVN OF SECURITY WALL ALONGWITH ALLIED INFRA AT LOWER BANDI GRN UNDER GE 969 EWS
2025_MES_698671_4
800168
Open Tender
Civil Works
Lump-sum
450 days
GE 969 EWS
As per tender documents
12 documents required · 12 mandatory
₹3,000
GE 969 EWS
₹5.9 L
Yes
17 Oct 2025
30 Aug 2025
29 Sept 2025
30 Aug 2025
26 Sept 2025
14 Sept 2025
30 Aug 2025 - 5 Sept 2025
Amount
Note: (i) Please refer Schedule 'A' Notes of tender documents. (ii) Unless otherwise specified, earth work and excavation shall be measured and paid separately. (iii) This Schedule 'A' Part-XI to XIV is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. (iv) In case rate of any item is not quoted by the bidder, the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-II.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-III.
Lump sum price worked out by the contractor for ROAD/ PATH/ HARD STANDING AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-IV.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-V.
Lump sum price worked out by the contractor for RETAINING WALL WORKS carried forward from Pre-Priced Schedule 'A' Part-VI.
Lump sum price worked out by the contractor for FENCING, SECURITY WALL AND GATE WORKS carried forward from Pre-Priced Schedule 'A' Part-VII.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII.
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-IX.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-X.
INTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' PART-XI)
Supply & Fixing of LED light fitting 1 x 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conuctor cable of suitable size from ceiling rose complete all as specified & directed.
Supply & Fixing of LED Lamp 9 Watt , 'T' type, complete all as specified & directed.
Supply & Fixing of LED street light fitting 25 Watt, 230V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, IP 65/66 protection complete all as specified & directed.
SEWAGE DISPOSAL WORKS (SCHEDULE 'A' PART-XII)
M&L for construction of 10 users LLPDE Septic Tank with upflow filter including media designed to carry sewage and sullage water, including excavation in any type of soil in foundation in PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) brick masonry in CM (1:4) RCC (M-30 design Mix) slab including cast iron manhole cover having 6mm embeded plate embeded all around with angle iron frame vent shaft etc. complete all as specified, directed and shown on drawing.
M&L for construction of soakage well of 1.8m internal dia and 3.00m deep below inlet level including necessary earth work filling with brick bats of guage 40 to 60mm, SWG inlet pipe junction 150mm bore including all other relevent works, complete all as specified, directed and shown on drawing.
EXTERNAL ELECTRIFICATION WORKS (SCHEDULE 'A' PART-XIII)
Supply, fixing and erect steel tubular swaged poles, ISI marked, complete with cast iron base plate, finial taper plug, bolts, nuts & screws drilling of holes for continous GI earth wire as specified type 410 SP-31 (9 metres long) including applying two coats of black bituminous paint internally throughout and externally upto embedded portion and applying two coats of synthetic enamel paint over one coat of red oxide primer with nblack and white strip of 30cm each upto 1.50 metre height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after preparation of surfaces and erection in position complete all as specified and directed. (NOTE : Excavation, Earthwork, PCC, channel, clamps, nuts, bolts shall be measured and paid separately under respective items)
Supply and fixing GI pipe, bracket for street light fittings made out of GI pipe medium grade 1.20 m long bent to required angle/shape including necessary clamps, nuts, bolts and washers of suitable size and applying two coats of aluminium paint with a base coat of red oxide primer complete all as specified and directed.
Supply and fixing PVC insulated unshealthed copper cable of size 1.50 sqmm 3 Core FR PVC for service connections from junction box to light fitting complete all as specified and directed.
Supply and fixing loopin loopout fuse junction box made of thermo plastic polycarbonate with IP 66/67 weather proof for outdoor installation of size 155x210x92 mm (with knockouts of cable entry) protection with terminals and locking screw fitted with 3 phase with neutral copper Bus Bar, 415 Volts, 50 Hz and 6A MCB SP, suitable for cables off sizes and fixing on steel tubular pole at height not less than 1.5m above ground level with the help of clamps two Nos. of F1 20 x 3mm and suitable nuts and bolts, complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire with 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or main switch or as directed including earthing pit in PCC (1:3:6) type C1 for chamber and pre-cast RCC cover of size 380 x 380 x 40 mm, frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 8 mm dia MS bar handle made to shape, 20 mm dia GI light grade pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed.
Note : (a) The quoted rate shall be deemed to include the cost of excavation & earth work in any type of soil. (b) The quoted rate shall be deemed to include the cost of charcoal and salt in alternate layers; GI strip and GI light grade protection pipe and GI medium grade watering pipe. (c) The quoted rate shall be deemed to include the cost of funnel, wire mesh, lugs, PCC, RCC, frame work and including provisions of testing of test point, connecting to test point and all the tests on completion. (d) Any variation in length shall be adjusted through deviation order.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire with 20 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or main switch or as directed including earthing pit in PCC (1:3:6) type C1 for chamber and pre-cast RCC cover of size 380 x 380 x 40 mm, frame of angle iron 25mmx25mmx3mm with lugs 02 Nos and with 8 mm dia MS bar handle made to shape, 20 mm dia GI light grade pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2009 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. NOTE:- For Internal Electrification Works = 5 Nos. For External Electrification Works = 6 Nos.
Note : (a) The quoted rate shall be deemed to include the cost of excavation & earth work in any type of soil. (b) The quoted rate shall be deemed to include the cost of charcoal and salt in alternate layers; galvanised wire 4 mm dia and GI light grade protection pipe and GI light grade watering pipe. (c) The quoted rate shall be deemed to include the cost of funnel, wire mesh, lugs, PCC, RCC, frame work and including provisions of testing of test point, connecting to test point and all the tests on completion. (d) Any variation in length shall be adjusted through deviation order.
Supply installation Testing & Commissioning of ECO friendly Diesel Engine driven generating set outdoor type of capacity 10 KVA not less than 16 BHP, latest CPCB-IV norms nearest higher side 400/440 volts, AC 3 phase, 50 HZ, 4 wire, 0.8 PF directly coupled alternator and engine Water cooled with AMF Panel common steel base fixed on cement concrete in foundation as per OEM recommendation DG set of 10 KVA platform with inbuilt AMF panel with 2 Nos suitable size of contactors as 01 no for main supply and 01 No for DG supply as per manufacturer's recommendation and other accessories comprising of following and complete all as specified and directed:- Notes :- 1. The DG Set should be design considering the derating factor of altitude 5204 ft above sea level (Bandi (J&K)) extreme cold climate in winters. The ambient temp varies from (-) 5 degree C (in winter) to (+) 35 degree C (in summer). 2. After considering of derating factor by manufacturer on above mentioned location, the net output is required of 10 KVA DG set. 3. The Plinth should be as per Manufacturer's recommendation and the rate of plinth is deemed to be included in quoted rate. (A) ENGINE- ECO friendly for emisson and noise (PCB NORM COMPLIACE) 4 stoke diesel Engine confirming to BS standard developing, 1500 RPM turbocharged watercooled complete with a provision for 10% overload for one hour on 10 KVA and with following accessories:-
i) Fly wheel with starter ring for generating set. ii) Dry type Air filter. iii) Lub oil cooler assembly with accessories. iv) Exhaust air manifold. v) Exhaust silencer. vi) Expansion bellow. vii) Exhaust gas turbocharger. viii) Fuel filter (pre micro). ix) Lubrication oil filter. x) 12V electrical starting system with starting motor & battery charging alternator with self-starter and other auto electric accessories as recommended by manufacturer. xi) Centrifugal by-pass filter. xii) Front & rear engine mounting supports. xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, electronic Hour meter, speedometer. xiv) Safety against low lub oil pressure. xv) Engine operation/Maintenance, spare parts Manual. xvi) Engine test certificate. xvii) Cold starting kit
(B) ALTERNATOR - Salient pole brushless copper wound type suitable for direct couple to engine self-excited, self-regulated with fast response thermistor type electronic automatic voltage withhold output voltage with in desired limit (+1%) Dynamically balanced 400/415 volts AC 3 phase 50 HZ, 4 wire 0.8 PF lagging 10 KVA 1500 RPM star connected (4 wire) screen protected drip proof enclosures with radial fan mounted on rotor with insulation class- H suitable for ambient temperature varies from (-) 5 degree C in winter to (+) 35 degree C in summer with following accessories:- i) One MS frame suitable for mounting of Engine & alternator. ii) Fuel tank of suitable capacity as per Manufacturer recommendation complete with fuel gauge inlet/outlet connections drain valve with plug etc. iii) Battery of suitable capacity as per manufacturer recommendation with copper leads and terminals of suitable size iv) One set of AVM pads fitted on base frame.
(C) Acoustic enclosure - It shall be suitable for 10 KVA DG set the degree of protection IP-42 conforming to IS - 2147 as under:- i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyester based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated. ii) The doors are gasketed with EPDM gaskets. iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg /M3 covered with fiber glass cloth and perforated powder coats sheet specially designed alienators (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per latest CPCB norms. iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. v) Emergency stop push button outside the container. vi) Provn of light inside the canopy 20W LED fitting with wiring and control switch.
Supply, install and commissioning Servo controlled oil cooled voltage stabilizer 10 KVA for automatic operation, three phase output, naturally oil cooled, indoor type & designed for the following parameters :- Input voltage range : 300V to 480V Output voltage : 415V + 2.5% phase to phase, 230V + 2.5% (phase to neutral) Duty cycle : Continuous (24 Hours) Suitability : All power factor loads Load type : Unbalanced Environmental Protection : IP-30 Class of Insulation : Class E No load Loss : Less than 0.4% Correction Speed : > 25V/sec Correction Motor : Heavy Duty synchronous motor 3 Nos Winding : Copper IS : 9815, 5142 Mounting : Preferably on Wheels Indication : 1. LED for input on (Yellow) 2. LED for output healthy (Green) 3. LED for output Trip (Red)
Supplying and fixing LT End termination joint 1100 V Grade suitable for XLPE cable of size 25 x 4 core complete all as specified and directed.
Supplying and fixing of GI wire 4mm dia for earthing complete all as specified and directed.
INCOMING TPN: (h) TPN, 32 Amp, 50 Hz, 415 V = 01 No. OUTGOING TPN: (j) TPN 16 Amp = 02 Nos. Note : The Cost of MCCB, TPN, Ammeters, Voltmeters, Bus Bar, Indication Lamps, Copper wiring, street light panel, spare slot, construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40mm thick crushed stone aggregates) and earthwork to be included in quoted rate. Drawings shall be approved by Accepting Officer.
Supply & Fixing of 100 Watt LED New Generation energy saving and environmently friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source and electronic drive suitable for pole, dia upto 58mm complete all as specified & directed.
FENCING, SECURITY WALL AND GATE WORKS (SCHEDULE 'A' PART-XIV)
Supply & Fixing of Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 8 RM, having a core wire of high carbon spring steel of high tensile strength. The punched tape and copper wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) to provided protection against outdoor exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm c/c. The weight of each coil shall be 8 + 5% Kgs without packing material and coil lenth of 8 Mtr (maximum) when opened up each coil would with bituminzed hessian cloth for providing protective packing Ref specification No CQAE/5660/1620/a for raw material and drawings IMGA-0112/B (Sheet 1 of 2), IMPD-1821, IMPD-1822 complete all as specified & directed.
M/s Muzaffar Ahmad Mir (BID ID -3429784)
M/S SHAH CONSTRUCTION (BID ID -3425548)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_815619.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .