Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹8.7 L+₹80,971 (10.3%)Rejected-Finance D NO 28 12 17 1 SURYA BAGH VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹9.0 L+₹1.1 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹9.5 L+₹1.7 L (21.1%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
14 Aug 2023, 6:00 pmClosed
Nitesh Kumar Singh, IDSE AEE(Civ)
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8465 REPAIRS/ REPLACEMENT OF LT UG CABLE, MCCBS, CABLE JOINTS, EARTHINGS AND CONNECTED EXTERNAL ELECTRICAL WORKS AT NSTL UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2023_MES_610520_1
AGE I R AND D NSTL VIZAG 8465
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Visakhapatnam
Class E Category b(i)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹19,600
Yes
30 Aug 2023
25 Jul 2023
16 Aug 2023
25 Jul 2023
14 Aug 2023
31 Jul 2023
Amount
Supply, laying and fix in repair LT Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including taking down old cable & testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size 16 sq mm 4 core. Note :i) The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. ii). The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items. Make of Cables:Polycab,Universal,Havells,Gloster
All as per item No.1 above but of size 35 sq mm X 3.5 core
All as per item No.1above but of size 50 sq mm X 3.5 core
All as per item No.1 above but of size 95 sq mm X 3.5 core
All as per item No.1 above but of size 185 sq mm X 3.5 core
All as per item No.1 above but of size 240 sq mm X 3.5 core
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: Siemens/ Legrand/ ABB/ L&T/ Havells/ Schneider
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, suitable to be fixed in LT panel complete all as specified and directed MMake: Siemens/ Legrand/ ABB/ L&T/ Havells/ Schneider
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: Siemens/ Legrand/ ABB/ L&T/ Havells/ Schneider
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: Siemens/ Legrand/ ABB/ L&T/ Havells/ Schneider
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 400 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 50 to 95 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5/4 core XLPE armoured, alluminum conductor cable of size 10 to 35 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
Supply and fixing cable jointing out door/indoor termination JOINT kit for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 400 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
Supply and fixing cable jointing out door/indoor termination JOINT kit for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5/4 core XLPE armoured, alluminum conductor cable of size 10 to 185 sq mm and all as directed by Engineer-In-Charge. Make :- 3M/ RAYCHEM/ COMPAQ
S&F of Aluminium lugs suitable for XLPE UG cable size of 10/16/25 sq mm
S&F of Aluminium lugs suitable for XLPE UG cable size of 35/50 sq mm
S&F of Aluminium lugs suitable for XLPE UG cable size of 70/95/120 sq mm
SS&F of Aluminium lugs suitable for XLPE UG cable size of 185/240 sq mm
S&F of Aluminium lugs suitable for XLPE UG cable size of 400/630 sq mm
Cutting trench of width 30cm and depth n.exc. 60cm through road/ hard standing for laying cable through GI pipe and returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm after laying the cable complete including provision of PCC type B1 filling for top 100mm layer all as directed.
GI Tubing light grade 40 mm dia for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified. Make: JINDAL/TATA/SURYA
All as per item No. 23above but of GI Tubing light grade 80 mm dia
All as per item No. 23 above but of GI Tubing light grade 100 mm dia
All as per item No. 23 above but of GI Tubing light grade 150 mm dia
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32x6 mm by mean of bolts, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe of suitable size including testing on completion all as specified and directed.
M&L Earthing continuity galvanised iron strip 32x6 mm dia or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth including taking down old cable all as specified & directed in any soil complete all as specified and directed.
M & L for Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm in thick all as specified and directed.
M & L for Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified by the Engineer-in-charge.
Supply and laying un-reinforced precast concrete cable cover Class LV type I, size 250 x 150 x 40mm
M&L for river dry sand cushioning to under ground cable intrenches including spreading, levelling and hand punning complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. Including taking down of old existing mat.
S&F in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make: C&S / L&T/ SCHIENDER
M&L for PCC earth pit chamber with cover suitable as per site requirement making good to disturb area complete as specified and directed by Engr-in-charge.
RK Associates
R AND A ASSOCIATES ENGINEERS CONTRACTORS
M/s SAI GANESH ENGINEERING ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .