Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹78.4 L+₹1.3 L (1.73%)Rejected-Finance OPP KIRYAPA PARK NATIONAL HIGHWAY ROAD BARAMULLA J K 193101 | NA | NA | 193101 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹79.8 L+₹2.7 L (3.49%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹80.0 L+₹2.9 L (3.75%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹80.3 L+₹3.3 L (4.24%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
1 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
SPL REPAIR TO HT UNDER GROUND CABLE AOR OF INF BDE NAUGAM UNDER GE 969 EWS BARAMULLA
2022_MES_500538_1
CWEK-65/2021-22
Open Tender
Electrical and Maintenance Works
Works
180 days
GE 969 EWS
Class C Category b ii
7 documents required · 7 mandatory
₹1,000
GE 969 EWS
₹1.5 L
HQ 133 WORKS ENGRS
15 Mar 2022
10 Jan 2022
8 Feb 2022
10 Jan 2022
1 Feb 2022
25 Jan 2022
10 Jan 2022 - 20 Jan 2022
21 Jan 2022
60 days
Amount
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5m deep any type of soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil, complete all as specified
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for dismantling earth wire or copper conductor, any type and any size, complete all as specified and as directed by the Engineer-in-Charge
M & L for dismantling cross-arms of M. S. channel or angle sections including nut,bolt and washers etc complete and removal from site complete all as specified and as directed by the Engineer-in-Charge
Dismantling insulators any type, any size complete all as specified and directed.
Dismantling of exisiting old underground cable any size any type from trench and handed over to contractor as Sch of credit complete all as specified and directed.
Dismantling of old unserviceable pipe any size from pole /road /wall and removing from site complete all as specified and directed.
Dismantling and taking down of ACSR/AAC conductor of any size from HT/LT over head line and removing from site complete all as specified and directed.
Dismantling stay assembly complete including demolition of concrete, necessary earth work ,returning filling, complete all as specified and directed.
M & L for dismantling air break gang operated switches vetical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. or carrying to MES store, spare/components for replecement to be provided free by department, complete all as specified and as directed by the Engineer-in-Charge
M & L for Gang operated air switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts, complete all as specified and as directed by the Engineer-in-Charge
M & L for expulsion fuse single pole, 11000 volts grade above 25 & upto 50 Amps, complete all as specified and as directed.
M & L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, , complete all as specified and as directed by the Engineer-in-Charge
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and directed.
M & L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25X20cm size, , complete all as specified and as directed by the Engineer-in-Charge
M & L for dismantling and taking down steel poles/struts, any type and size, from site and handed over to contractor as Sch of Credit complete all as specified and as directed.
Supply and fixing of 02 pole structure on 11 meter steel tublar pole consisting of pole with anti climbing device,PCC foundation and cross aram etc for one incoming and one out going complete all as specified and as directed.
Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-55 (11.0 metres long) including drilling of holes of reqd size foe fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and making pole NO.with black paint at suitable height complete all specified and directed.
Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-31 (9.0 metres long) including drilling of holes of reqd size foe fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and making pole NO.with black paint at suitable height complete all specified and directed.
Repairing / Servicing to gang oprating devices 11000 volts upto 200 Amps including gressing all the moving parts and applying white petroleum jelly at the contact points including dismantling and replacing all the unserviceable parts/spares complete all as per specified and directed. Note :- All the spare parts replaced will be measured and paid seprately.
(a) Supply only Moving contact blades copper
(b) Supply only Fixed contact jaw copper.
(c ) Supply only Tinned copper flexible jumper.
(d ) Supply only Jumper carrier..
(c ) Supply only Back connecter plate.
M&L for jumper connections between GOD and drop out fuses and transformer with ACSR conductor 6 of 1/3 not exc 2 mtr long including cable and binding properly without any loose contact after removing the old jumper complete all as per specified and directed by Engr-in-Charge.
All as per Srl Item No 25.00 above but length exc 2 mtr but not exc 3.5 mtr long complete all as specified and directed.
Supply and insert PVC sleeve of suitable size,HT electrical grade,ACSR conductor jumpers in the 2 pole /04 pole structure in red,yellow ,blue colour code and incerting to the ACSR jumper complete all as specified and directed by Engr-in-Charge.
Supply and fixing the breather only duly filled with silica jel suitable for the transformer of capacity 200 KVA after dismantling the old unserviceable jel container complete all as per specified and directed.
Supply and fixing the silica jel container ( breather) suitable for the transformer of capacity 100/63 KVA after dismantling the old unserviceable jel container complete all as per specified and directed.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of aluminium paint over one coat of red oxide primer, "as in repair" complete all as specified and directed.
M & L of ACSR conductor of any size and any type including stretching/tightening and disconnect/re-connect the incoming/outgoing cable, fixing and binding to insulator on OH/HT/LT line services feeder including aluminium binding wire or aluminium tapes fixed "as in repair" complete all as specified and directed.
M & L for Loop type insulator,vitreous porcelain,white, brown or green, large size, with overall dimensions 90 x 140mm clearance of hole 25.5mm, , complete all as specified and as directed.
M & L for disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, fixed "as in repair" complete all as specified and directed.
M & L of shackle type, porcelain (or polymer insulator if required , vitreous,white brown or green insulators for working pressure in 1100 volts , Height in 75 mm and Max 90 mm dia, Galvanised steel fittings Section of straps in 31 x 3 mm and 12 mm dia of bolts,fixed "as in repair" complete all as specified and directed.
M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade 150mm height 150mm dia for 11000 volts grade, fixed "as in repair" complete all as specified and directed.
M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade 100mm height 65mm dia for 1100 volts grade, fixed "as in repair" complete all as specified and directed.
M & L for Cradles, hexagonal/rectangular, fabricated with galvanized steel wire 3.15 or 4mm dia, , complete all as specified and as directed.
S&F cable route indicator(11KV) above the trench after refilling the soil complete all as specified and as directed.
M & L for painting to HT poles, 13/11/9 mtr , one coat of aluminium paint over one coat of red oxide primer including preparation of the old paint carefully to make smooth complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30 cm height with one coat of synthetic enamel paint all as specified and directed.
Restrectching of LT/HT OH line with necessary tripod stand etc complete keeping permissible sag complete all mas specified and directed. Note :- Three line together will be measured as one length
Cutting/Trimming/Chopping of tree branches along the overhead lines upto 3 m from elctric lines clearance on both sides of HT/LT,OH lines and disposing off the cut tree/branches site to a distance not exc 50 m and clearing the site complete as specified and directed.
M & L for UG cable for XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,HT 11000 volts, grade cross sectional area 95sq mm, 3 core, complete all as specified and as directed.
M & L for UG cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,LT 1100 volts, grade cross sectional area 95sq mm, 3.5 core, complete all as specified and as directed.
M & L for UG cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,LT 1100 volts, grade cross sectional area 70sq mm, 3.5 core, complete all as specified and as directed.
M & L for UG cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,LT 1100 volts, grade cross sectional area 50sq mm, 3.5 core, complete all as specified and as directed.
M & L for UG cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,LT 1100 volts, grade cross sectional area 16sq mm, 4 core, complete all as specified and as directed.
M & L for UG cable XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,LT 1100 volts, grade cross sectional area 10sq mm, 2 core, complete all as specified and as directed.
M & L for Cable Jointing Kit for 11 KV (Earthed) Grade cable for Outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 95 Sqmm complete as specified and directed.
M & L for Cable Jointing Kit for 11 KV (Earthed) Grade cable for Straight Through Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 95 Sqmm complete as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe
M & L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
M & L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp (suitable for 3300 volts), suitable for 11KV Volts, complete all as specified and as directed by the Engineer-in-Charge
M & L for stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), Diameter of stay rod in 20 mm, complete all as specified and as directed.
M & L for MCCB 3 pole, 415V, fixed type, 100 Amps with breaking capacity 16 KA fixed "as in repair" complete as specified and directed.
M & L for MCCB 4 pole, 415V, Adjustable type, 250 Amps with breaking capacity 36 KA fixed "as in repair" complete as specified and directed.
S & F for 80mm bore `Light grade` GI tubing with cutting as required and bend to shape for fixing with electric poles as cable protection complete all as specified and as directed by the Engineer-in-Charge
M/S GHULAM RASOOL LONE
M/s Lal Enterprises
Concept Engineering & Constructions
M/S M.A. Construction
Rajindera Enterprises
M/s Pall Constructions
M/S Razdan Buildersand suppliers
ALCO ENGINEERSPVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .