Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 31 A AVANTIKA ENCLAVE SEC 2 ROHINI NORTH WEST DELHI DELHI 110083 | NORTH WEST DELHI | DELHI | 110083 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | Admitted-Finance |
| 5 | Rejected-Technical D 52 FIRST FLOOR OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Rejected-Technical Technically Not Qualified |
Tender Value
₹27.1 L
EMD Value
₹54,237
Closing Date
9 Oct 2023, 5:00 pmClosed
EE (E)
Room No. 141, Engineering Department, Admin. Building, JNU, New Delhi-110067
Round the clock operation and Annual Maintenance Contract for repairing, maintenance of Fire Pump House near Central Library, Fire Alarm and Fire Fighting System in the various Academic, hostel and Residential buildings at JNU.
2023_JNU_772729_1
JNU/Engg./13/2023-24
Open Tender
AMC/ Maintenance Contracts
Item Rate
365 days
JNU
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹54,237
Yes
19 Oct 2023
21 Sept 2023
11 Oct 2023
21 Sept 2023
9 Oct 2023
22 Sept 2023
Amount
(A) Round the clock operation and checking, repairing & maintenance of Fire Pump system installed at Fire House near Central Library complete with replacement of minnor defective parts of pumps like bearing /gland / Nuts & bolts/ Packing/ Oil-seal, removal of pipe line leakages, part pertaining to electrical panel such as relay/ contractors/ indicating lamps/ lugs/ lubricants for blowers, Maintenance of 105 HP/77.28KW Diesel Engine(Kirlosker make Model 4R1040TA) including B&C check, Maintenace of software for PA /Fire Alarm system, equipments as per inventory and scope of work attached. (B) Routine checking, repairing & maintenance of addreseble/non addreseble fire alarm system & P.A. System installed in the following buildings complete with replacement of minnor electronics defective parts, repairing of control card, cleaning of smoke/heat detectors, fire control panels & associated accessories like MCP, RI, Hooter, SMF batteries etc. complete with preventive maintenance, breakdown maintenance as and when required at site as per the scope of work & inventory attached. (C) Complete checking, routine maintenance & minnor repairing of down commer type fire fighting system comprising of fire fighting pumps, Automatic electrical control panel, First Aid hose reels, landing valves, Non return valves, RRL hose pipe with 63 mm dia. Male & female coupling etc. in the following buildings complete with preventive maintenance, breakdown maintenance, gressing, oiling of pumps, replacement of gaskets, nut bolts, gland/mechanical seal etc. as and when required at site as per the scope of work & inventory attached.
Providing and fixing of following accessories complete with testing and commissioning complete as required at site i/c removing of defective one, connection, interconnection, thimbling, ferrulling etc. as required
Optical conventional smoke Detector
Optical Addreseblel smoke Detector suitable for ESSER make panel
Providing and fixing of following items in main panel/system of automatic F/D and F/A system complete with testing and commissioning etc. as required at site i/c removing defectiv one, connection, interconnection, thimbling, ferrulling etc. as required
Manual call Point (Conventional type)
Manual call Point (Addreseblel type) suitable for ESSER make panel
Hooter/Speaker (Conventional type)
Hooter/Speaker (Addreseblel type) suitable for ESSER make panel
Microprocessor Display board (up to 10 Zone)
Microprocessor Mother board (up to 10 Zone)
Microprocessor Mother board for ESSER make Addresable Fire Alarm Panel
Microprocessor Display board for ESSER make Addresable Fire Alarm Panel
Control Module 12 Relay suitalble for ESSER make Addresable Fire Alarm Panel
Monitor Module 4 in 2 out suitalble for ESSER make Addresable Fire Alarm Panel
Loop card suitalble for ESSER make Addresable Fire Alarm Panel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required i/c dismenteling the defective one etc. complete as required.
80 mm dia.
100 mm dia.
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required i/c dismenteling the defective one etc. complete as required.
80 mm dia.
100 mm dia.
150 mm dia.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required
Single headed Stainless steel
Supplying and fixing of 25 mm Air release valve complete with testing, commissioning i/c dismenteling the defective one etc. complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required i/c dismenteling the defective one etc. complete as required.
80 mm dia.
100 mm dia.
150 mm dia.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.
Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing of following items for swinging type first-Aid hose reel complete with testing, commissioning etc. as required.
30 Mtrs. Long 20 mm (nominal internal) dia. Water hose thermoplastic ( Textile reinforced) Type-2 as per IS: 12585.
25mm dia gun metal globe valve & nozzle
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supply, installation, testing & commissioning of following capacity power contactor & other accessories in the existing firecontrol panel for automatic operation of fire fighting pumps including dismenteling of defective parts, connection, interconnection, thinbling, ferruling etc. complete as required.
63 Amp. 415 V, 10 kA, TP MCB
32 Amp. 415 V, 10 kA, TP MCB
25/22 Amp. 415 V TP Contactor with NO/NC
Over load Relay for upto 10 HP pump
Rewinding of motor/ pump set with suitable copper conductor wire including replacement of defective parts, ball bearing, gland, testing etc. as required.
7.5/10HP 2800 RPM , three phase mono block motor pump set
Jocky pump 15HP, 2990 RPM
100 HP, 1480 RPM, three phase mono block motor pump set
Repainting on existing fire hydrant pipes and fittings with one coat of synthetic enamel paint of approved brand and manufacture and required colour to give an even shade etc.complete as required.
80 mm diameter pipes
100 mm diameter pipes
150 mm diameter pipes
NATIONAL SAFETY ENGINEERS
M/s Dogra & Dogra Enterprises
FACT SYSTEMS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .