| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr | L1 | Accepted-AOC Being L1 and found in order |
| 2 | L2₹5.2 Cr+₹34.3 L (7.07%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹5.2 Cr+₹34.3 L (7.07%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹5.3 Cr+₹41.5 L (8.56%)Rejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹5.3 Cr+₹41.5 L (8.56%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹5.3 Cr+₹42.9 L (8.86%)Rejected-Finance | ₹5.3 Cr+₹42.9 L (8.86%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹5.5 Cr+₹66.3 L (13.7%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹5.5 Cr+₹66.3 L (13.7%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
25 Mar 2024, 9:00 amClosed
Chief Engineer S C Negi
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly
PROVN OF KLP OF ESSENTIAL OTM ACCN FOR 116 INF BDE AT DEHRADUN
2024_MES_639014_1
CEBZ/DDN/T-23 OF 2023-24
Open Tender
Civil Works
Lump-sum
456 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE Project
₹5.9 L
Yes
1 May 2024
25 Jan 2024
1 Apr 2024
25 Jan 2024
25 Mar 2024
9 Mar 2024
25 Jan 2024 - 2 Feb 2024
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of Single JCO's Accn ( For 02 x JCOs) (D/S) with car and scooter shed (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Single living Accn for OR's ( For 03 Hav & 41 Ors) (T/S) with car and scooter shed (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Cook House and Dinning Hall for 21 to 50 OR's (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Drying and Ironing Room (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Barber Shop (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Armouries and Armourer Shop (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Storage Accn (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Dhobhi Ghat with permanent specification all as shown on drawings and as specified.
Construction of Garbage Bin (Refuse Bin) with permanent specification all as shown on drawings and as specified.
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II-B (Internal Water Supply)
S&F Brass Chromium Plated Wall Mixer 3 way fancy type for mixing hot and cold water screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated health faucet with 1 mt long flexible cord complete all specified and directed.
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE A PART III-B (Internal Electrification)
M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS-H grade) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of chases in wall (MS/ Galvanised Iron boxes for hanging of ceiling fans and for light points along with conduit be fixed in ceiling while casting slab for fan point and for light points,in rigid pvc conduit will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick and including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and -
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
(c) One 3/5 pin 5 Amps socket outlet on indepandant board.
(d) One light point controlled by two (two way switch )
All as per item No 6 above but 2.5 sqmm FRLS-H grade cable PVC for 15 Amp 3/5 pin socket power point including 2.5 sqmm copper conductor green as colour for earth continuity all as specified and directed.
All as per item No 6 above but 4 sqmm FRLS-H grade cable PVC for 15 Amp 3/5 pin socket power point including 2.5 sqmm copper conductor green as colour for earth continuity all as specified and directed.
S & F 125 Amp, 415 Volts four pole MCCB adjustable type with breaking capacity 16 KA and incl connections, testing and commissioning complete all as specified and directed.
Supply and fixing of MCB TPN, 100 Amps, 415 Volt,10 KA 'C' curve complete all as specified and directed.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) Vertical TPN, , 415 V, With 250 Amps rated copper bus bar, double door 8 way IP-54, IK-09 suitable for one MCCB as incomer and MCB TPN as outgoing mounted flush including cutting the wall surfaces for flush mounting of DB and making good with cemenet plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) Vertical TPN, , 415 V, With 250 Amps rated copper bus bar, double door 4 way IP-54, IK-09 suitable for one MCCB as incomer and MCB TPN as outgoing mounted flush including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) SPN 240Volt with 200 Amps rated copper bus bar, double door 8 way IP-43, IK-09 suitable for one MCB SPN as incomer and MCB SP as outgoing mounted flush, including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) SPN 240Volt with 200 Amps rated copper bus bar, double door 4 way IP-43, IK-09 suitable for one MCB SPN as incomer and MCB SP as outgoing mounted flush, including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S & F MCB SP, 5 - 32 Amp, 10 KA, single pole, 'C' curve, 240 V, 50 Hz, complete all as specified and directed
S & F MCB SPN, 40-63 Amp, 10 KA, single pole, 'C' curve, 240 V, 50 Hz, complete all as specified and directed
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 1.5 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 1.5 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 2.5 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 2.5 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 4.0 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 4.0 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 10.0 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 10.0 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 16.0 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 16.0 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
S& F LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and dfirected.
S& F LED light fitting high output diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders including LED lamp connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and dfirected.
Supply & fix LED lamp 12 watt, 220 volt AC decorative type connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
S&F ceiling fans 1200mm sweep 230 volt, Brushless direct current motor (BLDC) copper wound complete with blades, down rods, clamps, real insulator, nut, bolt, pin & washer, and other accessories, minimum air delivery 245 CFM, five star rated with squirrel cage induction motor complete all as specified and directed.
Supply, installation, testing and commissioning of 25 Litre capacity Water Heater Storage type, five star rating, electric, suitable for single phase , 50 Hz, AC supply, stainless steel inner assembly, 2 KW heating element, twin thermostat for water temperature and safety thermostat ,stove enamel outer body including minimum 1 M of three core 2.5 sqmm twisted copper cable PVC sheathed, three pin plug top, PVC connection 450mm long of 6 kg/sqcm with two sets of chromium plated adopter at each end suitable for 15 mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopters at ends at hot water outlet, with safety fusible plug conforming to IS complete all as specified and directed.
Supply, installation, testing and commissioning of 50 Litre capacity Water Heater Storage type, five star rating, electric, suitable for single phase , 50 Hz, AC supply, stainless steel inner assembly, 2 KW heating element, twin thermostat for water temperature and safety thermostat ,stove enamel outer body including minimum 1 M of three core 2.5 sqmm twisted copper cable PVC sheathed, three pin plug top, PVC connection 450mm long of 6 kg/sqcm with two sets of chromium plated adopter at each end suitable for 15 mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopters at ends at hot water outlet, with safety fusible plug conforming to IS complete all as specified and directed.
S & F building LED Light fittig 35 watt made up with pressure die cast aluminium housing,, heat resistant toughened glass, with IP66 protection and impact resistance of Ik07 with 10 KV built in surge device, better optics for uniform distribution complete with electronic driver including connecting up with three core copper conductor cable 1.5 sqmm size copper wire from ceiling rode to connector of light fitting complete all as specified and directed.
S & F building LED Light fittig 70 watt made up with pressure die cast aluminium housing,, heat resistant toughened glass, with IP66 protection and impact resistance of Ik07 with 10 KV built in surge device, better optics for uniform distribution complete with electronic driver including connecting up with three core copper conductor cable 1.5 sqmm size copper wire from ceiling rode to connector of light fitting complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed/ surface steel conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule) (a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
All as per item No- 6.28 above but point wiring with 2.5 Sqmm copper conductor FRLS-H
S&F flameproof DB SPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-65, IK-09 including flameproof MCB SPN 20 Amps-01 No, and Flameproof SP 6 to 10 Amps-02 Nos, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
SCHEDULE A PART VA (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART VB (Road, Path and Culvert)
M&L for 150 mm thick (compacted thickness) WMM in two layers (each layer of 75 mm thick), with broken stone coarse aggregate (Granite,Basalt or Trap stone) of grading 2 (63 to 40 mm size for 1st layer) and (50 to 20 mm size for 2nd layer) grading 3, spread, rolled and consolidated to required gradient, camber, level and super elevation with 8 to 12 tonne power roller complete all as specified and directed.
M&L for applying thermoplastic reflective paint as in road marking of minimum 2.5mm thick single coat of 100/150 mm wide using HOT MARK thermoplastic paint (Hot application) white or golden yellow by indigenous modern properly road marking machine as directed incl all ingredients such as binder glass beads shall titanium dioxide calcium carbonate inter filler thermoplastic complete all as specified and as directed.
Supply & fixing of (100 x100x20) mm (Cat eyes) made of non-breakable polycarbonate with electronically welded primatic Retro reflective in wet and dry condition body dust proof complete all as specified and directed.
Manufacturing,suppling and fixing retroreflective cautionary / warning sign boards ofequilateral triangle shape having each side of 900mm with support length of 3650 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-Lingual), symbols and borders etc as per IRC;67 : 2001 , pasted on substrate by an adhesive backing which shall be activated by appling heat pressure conforming to class-2 of ASTM-D 4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of MS angle iron of size 25 X 25 X 3 mm along with theft resistant measures, mounted and fixed with 2 Nos MS angles of size 35 X 35 X 5mm to a vertical post made up to MS tee section ISMT 50 X 50 X6 mm welded with base plate of size 100 X 100 X 5mm at the bottom end and including making holes in pipes, angles,flats, providing and fixing MS message plates of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours) backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc complete as per drawing , specification and direction of Engineer-in-charge.
Manufacturing, supplying and fixing retro reflective Overhead informatory road signage and boards, made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTMD-4956-01 as approved by Engineer-In-Charge, letters, borders, etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge. (Structural frame work including M.S. plate to be provided separately, Rectangular area of the sheet only shall be measured for payment)
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VI B (Sewage Disposal)
M & L for construction of septic tank 25 Users with class 'B' brick masonry wall, PCC in foundation floor, RCC cover slab including sludge chamber, CI vent pipe, CI cowl, inlet and outlet pipe, RCC baffle wall and necessary excavation and earth work complete all as specified and as directed. Note : Ref TD - 217, Sheet No 1/7 to 7/7
M & L for construction of septic tank 50 Users with class 'B' brick masonry wall, PCC in foundation floor, RCC cover slab including sludge chamber, CI vent pipe, CI cowl, inlet and outlet pipe, RCC baffle wall and necessary excavation and earth work complete all as specified and as directed. Note : Ref TD - 217, Sheet No 1/7 to 7/7
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete , RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 3 M effective depth all as specified and as directed.. Note : Ref TD - 309, Sheet No 1/4 to 4/4
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII (Fencing, Gate, Compound wall & Security wall) for details refer pdf folder
SCHEDULE A PART IX A (External Water Supply) for details refer pdf folder
SCHEDULE A PART IX B (External Water Supply)
Cutting cast iron pipes and reducing to required length in position for insertion of new Tee, branches etc dia 150 mm including CI fitting Tee, Reducer,Tail Piece ,Joints & required earth works. complete all as specified.
Supply and fix CI sluice valve 80 mm dia, flanged on both ends, class 1.5 PN complete all specified and directed.
Material and labour for construction of valve chamber of size (750x750x750) mm (internal dimensions) built in brick masonary 230 mm thick on 150 mm thick PCC foundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masonary in cement mortar 1:4 using 'B' class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 3 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge.
SCHEDULE A PART X A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART X B (EXTERNAL ELECTRIC SUPPLY)
Supply and Installation of Tubular steel poles shall be swaged type & shall conform to IS 2713 (Parts 1 to 3) 1980. A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arrangements. Finials and base plate shall be of cast iron and conform to the details given in fig. 3 and 4 of the Standard (IS-2713 Part 1*3 of 1980). Protection Against Corrosion The poles shall be coated with two coasts of black bituminous paint throughout internally and externally up to the planting depth. The remaining portion of the exterior with one coat of red oxide/emulsion paint & two coat of aluminium paint to GI bracket for street lights and two coats of zebra marking with enamel from ground level and upto 1 mtr hight including white washing the coping and cleaning the bushes surrounding the pole bottom upto 1 mtr width with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 31,(9.0 Mtr long) all as directed. Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600x600x 6 mm earth electrode buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 32x6mm earth strip as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 40 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
Supply and fix 11 KV outdoor type gang oprated air break switch suitable for horizontal or vertical mounting type fixed type complete on insulators of rating 200 Amps,operated by handle ,located at approchable height from ground level,all specified and directed.
Supply and errect steel tubular pole swaged ISI Marked 11 Mtr long type 410 SP-55 complete with MS base plate 450 x 450 x 6mm pole cap finial taper plug, nuts, washers etc and including Anti climbing device and danger notice plate,painting two coats of aluminium paint over one coat of red oxide primer, 3 Nos band straps with yellow and black colour (300mm wide 2 Nos each) synthetic enameled paint including one coat on steel surface embeded in concrete all as specified and directed Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.
Supply and fix cable jointing kit for 11 KV garde cable for outdoor termination, cold shrinkble type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm
M&L for laying dry clean sand filling in trenches / ducts for cushioning to under ground cable complete all as specified and directed. Note : Punned thickness shal be measured and paid.
M&L for laying un-reinforced precast concrete cable covers, class HV type -1, flat size (300x300x40) mm complete all as specified and directed.
M&L for laying well burnt old size, sub class 'B' bricks, in trenches, as protection of under ground cable complete all as specified and directed.
S&F Lightning arresters HT 11KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp with galvanised iron strip 32x6mm as earth lead connection upto earthing .
Supply, install, test and commissioning of transformer, outdoor type, step down 11/0.433KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC,50 HZ, 100KVA copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT bushing on primeyr side complete in all respects with standard accessories and fitments confirming to IS 1180 Energy efficiency level 2 transformer as specified and as directed including the following:-
(a) Earthing terminal and rating the diagram plate. (b) Air release device (c) Oil filling inlet pipe with plug (d) Drain outlet pipe with brass gate valve with dummy plug (e) Conservator with level guage (f) Silica get with breather (g) First Oil fill up to recommended level by the manufacturer with new oil conforming to IS 335 (h) Type of connection : Delta/Star (j) Type of cooling : ONAN (k) Vector Group : DYN 1 (l) Type of connceting arrangement cable termination boxes on HT side and on LT side. (m) Provision of thermometer with pocket
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including GI pipe mediam grade bracketwith clamp nut bolts and connected with three core multistranded aluminium conductor cable 2.5 sqmm from pole to fitting as required length complete all as specified and as directed.
S & F sheet metal enclosure IP-54 made out of MS sheet not less than 02 mm factory fabricated front openable duly painted of size 300×250×100mm deep having aluminium Bus bar 1 Ph and Neutral including one MCB SP 6 Amps with two Nos MS 25×3 mm clamps made to shape with required nut bolts washers etc for stree light fittings.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick burried directly in ground. (earth it not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below normal ground level connecting to galvanised wire of 4.00mm dia by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover RCC (1:2:4) reinforced with XOM (weight not less than 4 KG/Sqm) and frame of angle iron 25×25×3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. (FOR LT POLE & GOD) Note : Item of earthing includes cost of 7.5mm long galvanised wire 4mm dia and protection pipe of 15mm bore GI medium grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with
SCHEDULE A PART XI A (Cooling Appliances) for details refer pdf folder
SCHEDULE A PART XI B (Cooling Appliances)
Supply and installed desert cooler steel body electric driven (single phase), having nominal air flow capacity of 4000 Cum per hour (or nearest size). complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 volt with accuracy +2.5 % and capacity upto 2 KVA,with suitable size and length of wire complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 volt with accuracy +2.5 % and capacity upto 3 KVA,with suitable size and length of wire complete all as specified and directed.
Supply , installed and testing of Refrigerator with non CFC refrigrent type, electric driven Single phase of capacity 310 ltr air cooled sealed unit compressure BEE 4 star rated complete with PVC bottom stand complete all as specified and directed.
Supply , installed and testing of Deep freezer hard top 320 ltr air cooled sealed unit compressure BEE 4 star rated complete with PVC bottom stand complete all as specified and directed.
SCHEDULE A PART XII (Hot water supply)
Supply and fix electric water heater,storage type steel body with glass lined inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
M/s Arihant Builders
A.S. CONSTRUCTION CO.
M/s Ravindra Kumar Gupta & Sons
MOHAN LAL GUPTA
G and G Infratech Private Limited
SANJEEV CONSTRUCTIONS
VEE SONS BUILDERS PVT LTD
CHITTER MAL & CO
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .