Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC 2 FRIENDS ENCLAVE SHAH NAGAR DEHRADUN | ₹1.4 Cr | 1 | Accepted-AOC Lower bid rates |
| 2 | Not Admitted-Fee/PreQual/Technical INDRA NAGAR COLONY DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Rejected-Technical | - | - | Rejected-Technical bidder does not qualified in PQR |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
11 Mar 2024, 1:30 pmClosed
Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),,Dehradun
Construction of 33 KV AAAC AL-59, 241 sqmm covered conductor line from Kargi Chowk to 33/11 KV Substation Pathri Bag Palm city to provide 33 KV supply to 33/11 KV Pathribagh S/s from Deal feeder.
2024_UPCL4_70795_2
Tender No. 42/EDC(U)/2023-24
Open Tender
Electrical Works
Item Wise
120 days
as per tender specification
As Per tender Specificatin
4 documents required · 4 mandatory
₹11,800
Superintending Engineer, EDC (Urban),Dehradun
₹2.8 L
10 Sept 2024
4 Mar 2024
11 Mar 2024
5 Mar 2024
11 Mar 2024
5 Mar 2024
Decentralized Material
33 KV AAAC AL-59, 241 sqmm covered conductor(As per EN. 50397-1:2006) the contractor shall be stranded round, non compacted and water tight non compacted conductor shall comply with all the requirement of EN 50397-1-2003. The Stranded conductor shall be logitudinally water blocked by means ofmater blocking material. the semi conducting sreen, inner insulation and outer insulation should be extruded in one step. The outer covering insulation shall be UV- sablized tracking resistnat black XLPE.
33 KV isolator veritcal type
MVCC Accessories (As per EN 50397-2) as below
cable holding calmp with N&B for SP-55
Al lugs of size upto 400 sqmm
33 KV tension clamp with bari & IPC
33 kv cable ties for pin insulator
33 kv IPC for covered to covered connections
33 kv IPC for covered to Bare connections
33 KV Mid Span jointing kit
IPC with aluminium ball for earthing
PP and clmap for SP-55/33 with N& B
Earth clamp for SP-72 with N&B
stay clamp for SP 72 with N & B
Connector suitable for panther for following equipment
33 KV isolator vertical type
33 KV 630 A 25 KA/1sec SF6 insulated Ring Main Unit with 2 Nos VCB and 1 Nos LBS (Scada enebaled).
33 KV 3 x 400 sqmm pushon termination kit indoor type for 33 KV RMU
Labour Charges
cartage of following material from ESC to Road site of work dist. Apprx 0-55 Km loading/unloading com
ST Pole SP-72
Small material
Head load cartage of following material from road to work site dist. Apprx 0.2 Km loading/ unloading complete.
ST Pole SP-72
Small material
Fabrication of steel by cutting and drilling property.
Excavation of foundation pit of size 0.9 x 0.6 x 1/5th of length of pole in mixed soil of H.T./L.T. support as per UPCL Construction manual.
Erection and grouting of stay set with all acessories with tensioing, tightening and nozzaling complete.
Erection of ST pole SP-72 with all acessories as per UPCL manual.
ST Single Pole SP-72
ST D/Pole SP-72
Grouting of pole with CC as per UPCL norms
Muffing of above supports with CC as per UPCL Norms
Earthing of supports with earth rod as per UPCL Norms
Laying sagging and stringing of 33 KV line in 3 phase of the following wire as phase wire including proper sagging with binding and jumpering as per user manual and sagging com work done inclusive of cartage and head load cartage at work site. Rollers of the appropriate diameter and quantity have to be provided for installation. the rollers shall have smooth clean surface, no sharp edges and shall rotate easily. to prevent the covering from damage any abrasive contact with soil or stone is not permitted. Abrasive contact of the covering with branches or similar shall be avoided. covered conductor shall be pulled by using appropriate pulling devices ensuring that the pulling force is dis is distributed to the conductor recommendations given in EN- 50397-3 should be followed for storage transport and installation of covered conductor and removing of old conductor with opening of existing jumpering and making of bundle with carriage from work site to JE store including loading/ unloading complete.
33 KV AAAC AL-59, 241 sqmm covered conductor
Filling and fixing of 33 KV and termianation cable J.Kit (O/D)
Supply and fixing of GI Pipe (with socket) 6 inch Dia at cable rising at pole etc as per site requirement.
Laying of cable for loop and riser etc
Supply and fixing of danger/numper/name plate
fixing of MS channel, Angle and all accessories on existing/ New Single pole.
fixing of MS channel, Angle and all accessories on existing/ New Double pole.
Erection and fabrication of 33 KV isolator vertical type in proper alignment for smooth operation.
Supply and fixing of special earthing for at pole structure by 450 x 450 x10 mm G.I.Plate vertically 3M below the ground level with alternate layers of charcoal and salt atleast 200 MM thick around connected with G.I. strip running till top of pole complete.
Erection of 33 KV LA on DP before including proper earthing.
Fixing and commissioning of 33 KV SF6 Ring Main Unit including making of foundation and 2 Nos special earthing.
Fixing and commissioning of 33 KV 3 x 400 pushon termination kit Indoor type for 33 KV RMU.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .