12605-PATNA LPG RO
PAINTING WORKS AT RAJAHMUNDRY LPG PLANT
22000033-HD-12605
22000033-HD-12605
Open Tender
East Godavari, Andhra Pradesh
₹0
Exempted
29 Oct 2022
12 Oct 2022
29 Oct 2022
29 Oct 2022
11 Oct 2022 - 27 Oct 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | PAINTING OF PIPELINE | PAINTING OF PIPELINE — FINAL PU COAT PAINTING FOR MODIFIED/REROUTED PIPELINE-SUPPLY AND APPLICATION OF 100 MICRON DFT (TO BE ACHIEVED IN MINIMUM TWO COATS) OF EPOXY PU HB COATING OF APPROVED MAKE BY HPCL WITH APPROPRIATE SHADE IN TWO OR MORE NO. OF COATS TO PIPELINE OF FOLLOWING SIZE INCLUDING ALL FITTINGS LIKE VALVES, STRAINERS, BENDS, FLANGES ETC. COMPLETE. RATE TO INCLUDE WASTAGE'S, MIXING THE PAINT PROPERLY AS PER MANUFACTURER'S SPECIFICATIONS, APPLYING FIRST COAT WITH CONVENTIONAL SPRAY/BRUSH TILL 100 MICRON DFT OF PAINT THICKNESS IS ACHIEVED, TESTING FOR THICKNESS ETC. COMPLETE. RATE TO INCLUDE LOADING, HAULING, PROVIDING NECESSARY STEEL PIPE DOUBLE SCAFFOLDING FOR ALL HEIGHTS, HANDLING, AND TRANSPORTATION OF THE OWNER/CONTRACTOR SUPPLIED PIPES, PIPE FITTINGS, FLANGES ETC. THE JOB INCLUDES PROVIDING AND APPLYING ADDITIONAL COATS (FREE OF COST) TO THE SATISFACTION OF HPCL EIC IN CASE DESIRED THICKNESS (100 MICRON) OR PROPER SURFACE FINISH IS NOT ACHIEVED AFTER APPLYING TWO COATS. PAYMENT SHALL BE MADE ON THE BASIS OF INCH METER OF PIPELINE PAINTED, MEASURED ONLY ONCE.JOB TO BE EXECUTED AS STRICTLY AS PER "STANDARD SPECIFICATION FOR PIPELINE JOBS - SHOP AND FIELD PAINTING" ATTACHED UNDER TECHNICAL SPECIFICATION SECTION OF THIS TENDER. | - | Inch Meter |
| 2 | BRUSH CONVEYOR | BRUSH CONVEYOR — Painting of conveyor as per following scope of work:-first quality enamel paint of approved make, surface preparation, apply primer, fill the gaps with putty, finish with 2 to 3 coats of enamel paint. | - | Running Meter |
| 3 | PAINTING OF BUILDING | PAINTING OF BUILDING — APPLYING OF ACRYLIC PAINT OF APPROVED MAKE TO THE EXTERIOR SURFACE OF BUILDINGS AS PER DETAILS GIVEN BELOW:1. ERECTING OF THE METAL SCAFFOLDING (H FRAME) PROPERLY SO THAT THERE SHOULD BE SAFETY OBSERVED BEFORE THE PAINTING JOB IS STARTED. 2. SURFACE PREPARATION: SCRAPPING THE ENTIRE SURFACE WITH WIRE BRUSH AND REMOVING ALL LOOSE FLAKES/OLD PAINTS PROPERLY AND AFTER THIS IT SHOULD BE PROPERLY CLEANED AND BOOMED, THEN THE ENTIRE BUILDING SHOULD BE WASHED WITH WATER. THEN FILLING THE CRACK WITH WATER PROOF COMPOUND OF APPROVED MAKE. THEN FILLING ONE COAT OF EXTERIOR ACRYLIC WATER PROOF CORE PUTTY OF APPROVED MAKE AND FINISHING THE JOB WITH TWO COATS OF EXTERIOR ACRYLIC FINE PUTTY OF APPROVED MAKE. FINISHING THE ENTIRE JOB TO THE SATISFACTION OF THE SITE SUPERVISOR OR ENGINEER IN-CHARGE. 3. SCRAPPING THE EXISTING PUTTY FILLED SURFACE WITH SAND PAPER AND MAKING THE ENTIRE SURFACE SMOOTH. REMOVING AND CLEANING THE DUST SO FORMED WITH CLOTH AND THEN APPLYING BASE COAT OF ACRYLIC EXTERIOR ALKALI RESISTANT ALL WEATHER PROOF PRIMER OF APPROVED MAKE AS APPROVED BY THE SITE SUPERVISOR. FINISHING THE JOB COMPLETELY. APPLY ONE BASE COAT OF ACRYLIC CEMENT PAINT OF APPROVED SHADE AND COLOUR. 4. THEN APPLYING ONE BASE COAT OF EXTERIOR ACRYLIC EMULSION PAINT (AS APPROVED BY THE SITE SUPERVISOR) ALLOWS IT TO DRY. THEN AGAIN APPLYING THE SECOND COAT OF THE EXTERIOR ACRYLIC EMULSION PAINT AS APPROVED BY THE SITE SUPERVISOR. AND FINISHING THE ENTIRE JOB COMPLETE. CAUTION THE ACRYLIC EMULSION PAINT SHOULD NOT BE DILUTED WITH WATER AND SHALL BE APPLIED AS IT IS. | - | Square Meters |
| 4 | SPLY&APPLY OF WHITE WASH 12731-RAJAHMUNDARY LPG | SPLY&APPLY OF WHITE WASH 12731-RAJAHMUNDARY LPG — SCOPE OF JOB: PROVIDING AND APPLYING WHITE WASH ON OLD AND NEW PLASTERED OR MASONRY SURFACES CONFORMING TO IS:6278-1991 INCLUDING SCAFFOLDING AND PREPARING THE SURFACE BY BRUSHING AND BROOMING ETC. COMPLETE. (ONE COAT / TWO COAT / THREE COAT OR AS ADVISED BY HPCL ENGINEER). | - | Square Meters |
| 5 | PAINTING OF STRUCTURE | PAINTING OF STRUCTURE — SPRAY PAINTING OF STRUCTURES, PLATES, EQUIPMENT ETC. INCLUDING APPLYING PAINT PRIMER WITH 2 COATS OF APPROVED SYNTHETIC ENAMEL PAINT OVER A COAT OF ANTIRUST PRIMER. BEFORE PAINTING, THE SURFACE IS TO BE CLEANED BY SCRAPPING OLD PAINT AND CLEANING WITH SAND PAPER ETC. HAND PAINT SHALL BE ALLOWED ONLY IN CASES WHERE SPRAY PAINT IS NOT POSSIBLE. | - | Square Meters |
| 6 | PAINTING OF ARCH | PAINTING OF ARCH — APPLYING OF ACRYLIC PAINT OF APPROVED MAKE TO THE EXTERIOR SURFACE OF BUILDINGS AS PER DETAILS GIVEN BELOW:1. ERECTING OF THE METAL SCAFFOLDING (H FRAME) PROPERLY SO THAT THERE SHOULD BE SAFETY OBSERVED BEFORE THE PAINTING JOB IS STARTED. 2. SURFACE PREPARATION: SCRAPPING THE ENTIRE SURFACE WITH WIRE BRUSH AND REMOVING ALL LOOSE FLAKES/OLD PAINTS PROPERLY AND AFTER THIS IT SHOULD BE PROPERLY CLEANED AND BOOMED, THEN THE ENTIRE BUILDING SHOULD BE WASHED WITH WATER. THEN FILLING THE CRACK WITH WATER PROOF COMPOUND OF APPROVED MAKE. THEN FILLING ONE COAT OF EXTERIOR ACRYLIC WATER PROOF CORE PUTTY OF APPROVED MAKE AND FINISHING THE JOB WITH TWO COATS OF EXTERIOR ACRYLIC FINE PUTTY OF APPROVED MAKE. FINISHING THE ENTIRE JOB TO THE SATISFACTION OF THE SITE SUPERVISOR OR ENGINEER IN-CHARGE. 3. SCRAPPING THE EXISTING PUTTY FILLED SURFACE WITH SAND PAPER AND MAKING THE ENTIRE SURFACE SMOOTH. REMOVING AND CLEANING THE DUST SO FORMED WITH CLOTH AND THEN APPLYING BASE COAT OF ACRYLIC EXTERIOR ALKALI RESISTANT ALL WEATHER PROOF PRIMER OF APPROVED MAKE AS APPROVED BY THE SITE SUPERVISOR. FINISHING THE JOB COMPLETELY. APPLY ONE BASE COAT OF ACRYLIC CEMENT PAINT OF APPROVED SHADE AND COLOUR. 4. THEN APPLYING ONE BASE COAT OF EXTERIOR ACRYLIC EMULSION PAINT (AS APPROVED BY THE SITE SUPERVISOR) ALLOWS IT TO DRY. THEN AGAIN APPLYING THE SECOND COAT OF THE EXTERIOR ACRYLIC EMULSION PAINT AS APPROVED BY THE SITE SUPERVISOR. AND FINISHING THE ENTIRE JOB COMPLETE. CAUTION THE ACRYLIC EMULSION PAINT SHOULD NOT BE DILUTED WITH WATER AND SHALL BE APPLIED AS IT IS. | - | Square Meters |
| 7 | PAINTING OF ARCH | PAINTING OF ARCH — APPLYING OF ACRYLIC PAINT OF APPROVED MAKE TO THE EXTERIOR SURFACE OF BUILDINGS AS PER DETAILS GIVEN BELOW:1. ERECTING OF THE METAL SCAFFOLDING (H FRAME) PROPERLY SO THAT THERE SHOULD BE SAFETY OBSERVED BEFORE THE PAINTING JOB IS STARTED. 2. SURFACE PREPARATION: SCRAPPING THE ENTIRE SURFACE WITH WIRE BRUSH AND REMOVING ALL LOOSE FLAKES/OLD PAINTS PROPERLY AND AFTER THIS IT SHOULD BE PROPERLY CLEANED AND BOOMED, THEN THE ENTIRE BUILDING SHOULD BE WASHED WITH WATER. THEN FILLING THE CRACK WITH WATER PROOF COMPOUND OF APPROVED MAKE. THEN FILLING ONE COAT OF EXTERIOR ACRYLIC WATER PROOF CORE PUTTY OF APPROVED MAKE AND FINISHING THE JOB WITH TWO COATS OF EXTERIOR ACRYLIC FINE PUTTY OF APPROVED MAKE. FINISHING THE ENTIRE JOB TO THE SATISFACTION OF THE SITE SUPERVISOR OR ENGINEER IN-CHARGE. 3. SCRAPPING THE EXISTING PUTTY FILLED SURFACE WITH SAND PAPER AND MAKING THE ENTIRE SURFACE SMOOTH. REMOVING AND CLEANING THE DUST SO FORMED WITH CLOTH AND THEN APPLYING BASE COAT OF ACRYLIC EXTERIOR ALKALI RESISTANT ALL WEATHER PROOF PRIMER OF APPROVED MAKE AS APPROVED BY THE SITE SUPERVISOR. FINISHING THE JOB COMPLETELY. APPLY ONE BASE COAT OF ACRYLIC CEMENT PAINT OF APPROVED SHADE AND COLOUR. 4. THEN APPLYING ONE BASE COAT OF EXTERIOR ACRYLIC EMULSION PAINT (AS APPROVED BY THE SITE SUPERVISOR) ALLOWS IT TO DRY. THEN AGAIN APPLYING THE SECOND COAT OF THE EXTERIOR ACRYLIC EMULSION PAINT AS APPROVED BY THE SITE SUPERVISOR. AND FINISHING THE ENTIRE JOB COMPLETE. CAUTION THE ACRYLIC EMULSION PAINT SHOULD NOT BE DILUTED WITH WATER AND SHALL BE APPLIED AS IT IS. | - | Square Meters |