Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹23.0 L+₹2.4 L (11.5%)Rejected-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹25.5 L+₹5.0 L (24.1%)Rejected-AOC | L3 | Rejected-AOC Quoted L3 |
Tender Value
₹29.3 L
EMD Value
₹58,600
Closing Date
25 Aug 2021, 6:00 pmClosed
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003
SPECIAL REPAIR TO INTERNAL WIRING AND LIGHTS OF BLDG NO P-3 AND PROVN OF CERTAIN MINOR/ DEPOSIT WORKS AT AF STN KASAULI UNDER GE (AF) CHANDIGARH
2021_MES_463699_1
GE(AF)/CHD/T-21/2021-22
Open Tender
Civil Works
Item Rate
180 days
KASAULI
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE(AF) Chandigarh
₹58,600
Yes
19 Dec 2021
30 Jul 2021
27 Aug 2021
30 Jul 2021
25 Aug 2021
12 Aug 2021
30 Jul 2021 - 5 Aug 2021
Amount
Dismantling of wall and ceiling boards(fibre pulp,insulation,etc)or insulation boards/slabs/blankets any thickness, including cover fillets and snap grid, Complete all as specified and directed by Engineer-in-Charge.
S&F, Metal suspended ceiling system OREO GI laid in plain 600X600X0.50 mm (tegular) edge tiles in global white colour to be laid on strong 24mm T-section flanges colour white having rotary stitching on the main runner with web height of 38mm. Note:(i) To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit at 1200mm maximum centre.The first/last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200x600 mm mould.Cut cross tees longer than 600mm require independent support. 600X600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm,secured to walls at 450mm maximum centres. (ii) Suspension system accessories consisting of HLC sleeve anchor fasterners of thread size 6.50 mmx25/5 with soffit cleat made of galvanised steel of size 27x37x25x1.60mm & level clip in dimensions of 85x30x0.80 mm with 4mm GI wire complete all as specified & directed. Make : High steel,Armstrong & Dexune.
Material and labour for preparation of old surface of wood and wood based materials over 10 Cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and directed by Engineer-in-Charge.
M & L for applying one coat of synthetic enamel paint to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of old steel surfaces,Complete all as specified and directed by Engineer-in-Charge.
M & L for Complete removal of existing treament from wall surfaces by wire brushes & stopping of surfaces & leveling/edging the disturbed surface /edges using 1.0 mm thick fillig compound of birla/Jk wall care putty to obtain smooth regular /even finish using sand paper and applying two coats of oil bound distemper over a caot of alkali resistant primer, Complete all as specified and directed by Engineer-in-Charge.
Material & labour, preparation of new (plastered or unplasterd) surfaces of walls including brooming down, washing, rubbing down using sand paper, stopping distrubed surfaces, planes/edges with white cement putty & rubbing with sand paper to obtain regular and smooth surfaces, and applying two coats of exterior acrylic emulsion anti weather & anti algae paint (1st quality paint), in disruptive pattern (camouflage) using number of colours as approved, over and including a coat of alkali resistant primer, complete all as specified and directed. Note (s): (i) Pattern of camouflage shall be as approved by GE. (ii) Rate quoted by contractor shall be deemed to include the cost of use and waste of necessary ladder, wooden platform etc,. as may require to execute work at any height upto 8.00 metre. (iii) Painting work shall stand guaranted against fadding/Peeling off for 05 years & the cost agaist this aspect, shall be deemed included in the unit rate quoted for this item.
Dismantling aluminium Partition of any description all as specified and directed.
S&F powder coating of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm,Complete all as specified and directed by Engineer-in-Charge.
All as per item No 09above but area not exc 1.50 Sqm.
S&F powder coating of any colour (Thickness or powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, 200 mm aluminium handles D type 2 Nos in each door, 100mm stainless steel hinges 3 Nos in each door, anodised aluminum snap beading screws etc. complete all as specified
S&F 5 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane Complete all as specified and directed by Engineer-in-Charge.
S&F 12mm thick prelaminated particle board, exterior grade prelaminated both sides with decorative choice laminated fixed in aluminium shutter/ partition Complete all as specified and directed by Engineer-in-Charge.
S&F Door closer hydraulically regulated,Aluminium (extruded section body) designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed, Complete all as specified and directed by Engineer-in-Charge.
S&F, Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor overall 140 mm length,Complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed by Engineer-in-Charge.
Dismantling of water tanks exc 250 ltrs & n. exc 500 ltrs capacity and removing to store,Complete all as specified and directed by Engineer-in-Charge.
S & F PVC water storage tanks white colour of 500 ltrs capacity rotational moulded (tripple layered cylindrical vertical with closed top) hoisted and fixed in position Complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level),Complete all as specified and directed by Engineer-in-Charge.
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil Complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick plain cement concrete type C-1, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth using extra cement,Complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick plain cement concrete type C-1, 1:3:6, (40mm graded stone aggregate)as in sub floor, finishing the top surfaces even and smooth without using extra cement,Complete all as specified and directed by Engineer-in-Charge.
M&L, Linoleum, plain coloured ,3.2/3.3 mm thickness including stretching, cutting and fitting in and sealed down with an approved adhesive in floors,Complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick, concrete stone surfaces etc including raking out joints, hacking for key, scrubbing down with water etc,Complete all as specified and directed by Engineer-in-Charge.
M & L 15 mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finished even & smooth without using extra cement, Complete all as specified and directed by Engineer-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering,Complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork/ brick masonary built in cement lime mortar, including all quions, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense soil Complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils Complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soils, Complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete Complete all as specified and directed by Engineer-in-Charge.
M&L brickwork with sub class 'B' bricks straight or curved on plan exc 6m mean radious, built in CM 1:6 complete all as directed by Engineer in Charge.
M&L Fair cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc. including rubbed finish and waste ,complete all as directed by Engineer in Charge.
S&F, Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates AFe-290(Gde E-165),complete all as directed by Engineer in Charge.
S&F, Pre- painted galvatumealuminum zinc coating GI based corrugated steel sheet 0.50mm thick of ancolour having tensilestrength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified.
S&F Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self taping screws complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long diameter of neck 5 to 10 mm,complete all as specified.
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete surfaces on wall finished even and smooth without using extra cement,complete all as specified.
M&L for rendering 10 mm thick in CM 1:6 to wall finished even and smooth without using extra cement,complete all as specified.
Preparation of new previously untreated steel surfaces of any despcription, over 10 cm width or girth, otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as directed by Engineer in Charge.
Preparation of new plaster surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm and Refixing in other opening,Complete all as specified and directed by Engineer-in-Charge.
Supplying, fabricating and fixing Aluminium Windows, Triple Track, fabricated with powder coated aluminium section with three sliding shutters(02 Glass and 01 Guazed) with following section including joining cleats, glazing clips, rubber packaging, snap beading and other necessary builders hardware as required all as directed by Engineer incharge. [a] Top and side members for three track frame shall be of size 92.00 x 31.75 x 1.5 mm [b] Three track bottom rail of frame for sliding of shutter shall be of size 92.00 x 31.75 x 1.5 mm [c] Top and bottom rail of sliding shutter shall be of size 40 x 18 x 1.55 mm [d] Side rail of sliding shutter with handle and self locking arrangement section shall be of size 40 x 18 x 1.55 mm [e] Sliding shutter to be provided with 5.5mm thick Tinted Glass. [f] One shutter to be provided with stainless steel wire cloth 0.36mm dia and aperture 1.4mm
Supplying, fabricating and fixing Aluminium powder coated door shutter with two panel made of vertical style and top rail 83mm x 44mm, bottom rail 150mm x 44mm and middle rail 115mm x 44mm, all aluminium section shall be 2 mm thick, including all fittings per door shutter such as aluminium door handles round type/ curved ‘D’ type – 2 Nos., stainless steel hinges 100 mm size – 4 Nos., central mortice lock, aluminium tower bolts 250 mm – 2 Nos., double leg aluminium anodized door stopper and hydraulic door closer, designation No. 2, universal type, cast iron body, ISI marked and necessary clips, rubber packing and aluminium beading to receive 5.0 mm thick plain tinted glass or 12 mm thick prelaminated board in top and bottom panel, complete all as specified and as directed by the Engineer-in-Charge.Note: Tinted glass and prelaminated board shall be measured and paid for separately.
Material and labour joint free non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry @ 3.0 Kg/Sqm over 15 mm thick screed bed in cement mortar 1:6 , pointed in white or coloured cement to match, complete all as spcified.
Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface (hard/dense soil) complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate in posts complete all as specified and directed by Engineer-in- Charge.
S&F , Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of grde Fe 290 (Gde-E-160) quality A complete all as specified and directed by Engineer-in- Charge.
S&F Rolled mild steel sections as in roof trusses(framed), trussed, purlins, crane gantries, rails and fasternings and heavy bracket framing (beam, tee, angle,channel or flat sections) including distance pieces, cleats etc of grde Fe 290W (Gde-E-160) quality A , complete all as specified and directed by Engineer-in- Charge.
S&F Mild steel Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D2 75 mm thick using 40mm graded stone aggregate as in Cement concret in sub floors, floors and pavings complete all as specified.
M&L PCC 1:2:4 type B1,50 mm thick using 20mm graded stone aggregate as in Cement concret in sub floors, floors and pavings complete all as specified.
M&L PCC 1:5:10 type D2, using 40mm graded stone aggregate as in Cement concret in foundations filling and mass concrete complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from surrounds, glazed with putty or fixed with beads metal frame glass is removed from patent glazing bars removing any serviceable glass to store and rubbish off the premises; and also painting/oiling new putty to match existing painting/oiling complete all as specified &directed
S & F 3 mm thick polycarbonate transparent sheet not exceeding 0.5 sq. m in each pane fixed with steel grooves / M seal or both, complete all as directed by Engineer in Charge.
Taking down carefully aluminium/copper point wiring (light/fan/socket/ power) complete including fittings such as switches, sockets, ceiling roses pendents, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall all as specified and directed by Engineer-in- charge
Taking down unserviceable any type of Main Switch, industrial sockets, DB's including MCBs incl wooden/GI/MS sheet board,removing the materials/debris and making good the disturbed surfaces of wall, floors and ceiling etc. to match with the original existing finish all as directed etc all as directed.
Taking down carefully copper/Aluminium submain wiring of any size/core/type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of wall, floors and ceiling etc. to match with the original existing finish all as directed
Taking down unservicable light fittings any type all as directed.
Point wiring with approved colour coding as per IS with multistranded copper conductor 1.5 Sq mm (nominal area), single core, flame retardent low smoke (FRLS), PVC insulated and un sheathed cable 1100 Volts grade, ISI 694 marked TEC and FIA approved in and including PVC concealed conduit medium grade, suitable for light/bell/fan point terminated in and including mild steel terminl boxes covered with new 3 mm thick HYLAM Make plastic laminated sheet and controlled by one switch including flame retardent low smoke (FRLS) PVC insulated un sheathed multistranded copper conductor 1.5 Sq mm (nominal area)single core cable as earth continuity conductor to common earth and connected to earth dolly , complete all as specified and directed. Note :-The cost of making good to the disturbed surfaces to match with the adjescenet surfaces shall be deemed to be included in the quoted rate.
All as per srl item No 60 here in before but for multipin socket outlet 5 Amps multi purpose on the same board with other switches including continuous earth wire PVC insulated, unsheathed, single core multi stranded copper conductor cable 1.5 Sqmm & connected to earth dolly. (Switch and socket to be measured and paid for separately).
All as per srl item No 60 here in before for multipin socket outlet 5 Amps multi purpose on independent board using 1.5 sqmm and 1.5 sqmm multitranded copper conductor cable for wiring and earth continuity conductor respectively. (Switch and socket to be measured and paid for separately).
All as per srl item No 60 here in before for multipin socket outlet 15 Amps multi purpose on independent board using 4.0 sqmm and 1.5 sqmm multitranded copper conductor cable for wiring and earth continuity conductor respectively. (Switch and socket to be measured and paid for separately).
Supply and fixing of switch piano type, flush type, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fixing switch piano type, flush type, single pole, one way, 15 Amps, complete all as specified and directed.
Supply and fixing socket outlet flush type 3 pin, 5 Amps multipurpose , complete all as specified and directed.
Supply and fixing of socket outlet, flush type, multi purpose multipin , 5 Amps & 15 Amps, 230 volts, complete all as specified and directed.
Supply and fix, of ceiling rose surface bakelite 65 x 50 mm, two to three terminals, complete all as specified and directed.
Supply and fixing of MCBs , SP , 240 Volts , 6 Amps to 32 Amps , B curve , 10 kA , complete all as specified and directed.
Supply and fixing of MCBs , SPN , 240 Volts , 40 Amps , B curve , 10 kA , complete all as specified and directed.
S & F Sheet metal distribution board double door , vertical type VTPN suitable for mounting of MCCB 4 pole as incoming and MCBs as outgoing, including earth dolly made of CRCA sheet of thickness 1.6 mm with IP- 43 protection, 8 ways, 415 volt, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, of MCBs Distribution board , sheet metal enclosure, SPN 240 Volts , 12 ways with 200 amps rated bus bar , double door for MCBs, ,with IP 43 protection ,complete all as specified and directed.
S & F MCCB, four pole, 100 Amp, 415 Volts, 25 KA, including making in coming/ outgoing connections, fixed in repairs, complete all as specified and directed.
Supply and Fix Heavy duty Exhaust fan AC single phase 230 Volt of size 300 mm sweep,1400 RPM with louvre and flexible cable 3 core copper conductor 1.50 Sqmm up to ceiling rose Complete all as specified and directed. Make: Havells Model Turbojet SP or equivalent in Khaitan/Usha/Crompton
Cutting of hole for fixing of exhaust fan complete and making good disturbed surface all as specifed and directed.
Supply and fixing ,in repairs LED Decorative batten fitting 1x18 to 22 W, prewired suitable for retrofit LED tubes , prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs LED tube rod 20 watts ( retrofit LED tube ) ,energy saving ,recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 22W, complete all as specified and directed.
S & F in repairs 36 W 2'' X 2'' CRCA LED deep drawn panel recess mounting luminaire suitable for armstrong/grid/Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and directed by Engr-in-charge.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1, RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old u/s earthing materials complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance shall be less than 5Ohm. In case test results are not found below 3Ohm, complete earthing will be re-done without any extra cost to Govt.
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through PVC conduit concealed/recessed as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. Note:- 2 runs of 4 Sq.mm main cable + 2 run of 2.5 Sq.mm earth cable + PVC conduit considered and as 1 Running Metre.
M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC conduit concealed/recessed as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. Note:- 2 runs of 6 Sq.mm main cable + 2 run of 4 Sq.mm earth cable + PVC conduit considered and as 1 Running Metre.
M & L for sub main wiring with 4 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC conduit concealed/recessed as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. Note:- 4 runs of 10 Sq.mm main cable + 2 run of 6 Sq.mm earth cable + PVC conduit considered and as 1 Running Metre.
Supply and fixing, factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket etc complete with provision for one single pole 'B' series MCB 20 Amps 240 Volts, all as specified and directed.
Supply and fixing of Exhaust Fan , Steel body AC singe phase 230 V of size 300 mm sweep with , blades and frame and louvers, all as specified and directed. Make: Havells Model Ventil Air-DB or equivalent in Khaitan/Usha/Crompton
Supply and fix of ceiling fan regulators step type electronic for 1200/1400 mm sweep ceiling fan and connecting up complete with provision of PVC flexible cable size 1.5 Sqmm twin core copper conductor , complete , all as specified and directed.
Supply and fixing of MCBs , SP , 240 Volts , 6 Amps to 32 Amps , C curve , 10 kA , complete all as specified and directed.
Note:- Amount of credit of Rs. 22796.00 for retrieved materials is mentioned in Schedule of Credit Page No 120 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Vinod Kumar Aggarwal
Azurite Engineering
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .