Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
17 Aug 2026, 6:05 pmClosed
Chief Officer, Vadnagar Nagarpalika
(Second Attempt) Bid Documents for Constructing of C.C.road, Pever block and Street Light Pole work Hatkeshvar Scoiety at Vadnagar, Dist: Mehsana (Janbhagidari Yojana)
332635
VAD/06/2026-27/Retender/ Second Attempt
Open
Civil Works - Others
Works
Mehsana
1 document required · 0 mandatory · 1 optional
₹1,770
chief officer vadnagar nagar palika
₹30,000
7 Aug 2026
7 Aug 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
Name of work: (Second Attempt) Bid Documents for Constructing of C.C.road, Pever block and Street Light
Pole work Hatkeshvar Scoiety at Vadnagar, Dist: Mehsana (Janbhagidari Yojana)Bid Documents for
Constructing of C.C.road, Pever block and Street Light Pole work Hatkeshvar Society at Vadnagar, Dist:
Mehsana (Janbhagidari Yojana)
Qty. Description Rate Unit Amount
1 2 3 In Words 5
Demolation and Disposal unsericeble matrail all lead and lift (i)
Five Hundred Forty-One
1 175.50 Cement Concrete 541.19 and Nineteen Paise Only
Box cutting the road surface to proper slope and camber for making
a base for road work including removing the excavated stuff and One Hundred Nine and
2 354.75 depositing on the road side slope as directed upto 50Mt.lead. 109.04 Four Paise Only
Add. Extra for disposing of the excavated stuff of above items for One Hundred Twenty-Nine
3 530.25 lead of (e) 400M to 500M 129.28 and Twenty-Eight Paise cum
Providing and laying cement concrete 1:3:6 (1-Cement : 3-
coarse sand : 6- Crushed stone aggregates 40 mmnominal
Three Thousand Sixty-
4 179.25 size) and curing complete excluding cost of formwork in 3063.00 Three Only
(A) Foundation and Plinth (upto 10 ton)
Providing and laying ordinary cement
concrete M 200 (1:1.5:3)and curing complete excluding the cost of
reinforcement for R.C.C work in Road by Trimix method by providing
and Fixing 'C' channels of 100mm x 100mm as per required level
slope and thickness of concrete road levalling of placed concete Four Thousand Five
5 179.25 with surface vibrator finishing the surface with power floater and 4518.33 Hundred Eighteen and cum
trowel ligh brooming on the surface including providing and Thirty-Three Paise Only
filling expansion joint having size 20mm x 20mm as per
manufactures spacification and making construction joint 3mm x
20mm by using concrete cutter machine etc. complete as
Raising existing mainhole house connection chamber including fram Two Thousand Sixty and
6 10.00 & cover to the required final road level (Up 2060.58 Fifty-Eight Paise Only
Providing and fixing pre-cast Rubber Dye /steel Dye inter locking
concrete block 60mm thick with grade of concrete M300 Pnumatic
compressed / vibrated mechanically and as per approved design Six Hundred Ninety-Nine
7 1088.15 Confirming to IS 15658: 2006 including 35 mm Sand layer for 699.84 and Eighty-Four Paise SMT
levelling and filling the joint with sand in proper line and level as per
guidlines of IRC: SP 63-2018 etc. Complete
Providing and fixing pre-cast concrete kerb stone of gray cement
based concrete block 30cm length, 30cm height and 15cm thick of
M200 grade concret as per approved design and including Four Hundred Four and
8 482.70 excavation for fixing in proper line and level, filling the joint with C:M 404.05 Five Paise Only
1:3 (1cement: 3fine sand) etc complete
Supplying & erecting Steel tubular pole (Swaged) confirming to IS -
2713 (Part-Il) 1980 Manufacturing process of steel tubular pole
should be as per IS specification. Basic steel tube should be ISI
Marked Pole should be painted hy one coal of Zinc comet Primer and
Nine Thousand Five
9 11.00 two coal of Aluminium /approved paint to ho erected on 1 in existing f- 9520.00 Ea.
Hundred and Twenty Only
oundation 1 he length ol poles are as below (B i 8 5 mtr Long
Swaged Steel tubular pole (i) Pole as per IS code 410-SP-16 with
300 X 300 X 4 mm base plate with necessary G I .) Bolts
(Approximate weight 75 Kg) For burial erection
(li) Add Extra for M S Base plate 300 X 300 X 16 mm for pole One Thousand One
10 11.00 mounting on sudace of foundation on Gl foundation bolt with reguirea 1147.00 Hundred and Forty Seven Ea.
stiffeners Only
11 11.00 (ill) Add Extra for PU base primer and PU Paint on pole
Five Hundred and Seventy
Providing and erecting street light pole bracket comprising main B
Class MS pipe of 42 cm/reguire outside dia complete with suitable B
Class M S sleeve tubing ol approx 45cms length and suitable lor
mm / 80mm / require size pole top having sufficient fasteners for
fixing the brackets and having spread of 1 mtr length with suitable Eight Hundred and Eighty
12 11.00 rise as per site condition & suitable welded stiffener reducer and 885.00 Five Only
nipple with check nut complete painted with onetcoat of Red oxide /
PU base primer and two coats ol Aluminium / PU paint paint with
following nos ol arms |B| Double Arm Bracket 1 Mtr
Supplying and ercting LED street light / Flood Iight fittings with High
power white LEDs wattage of 3 Watt and above assembled on single
MCPCB. efficiency more than l30lm/w and corrosion free High
pressure die cast aluminum housing with smooih finish powder
coated and heat sink extruded aluminium with difluser and
Polycarbonate optics/ lenses with toughened glass with company
mark/narne engraved or embossed 160 Io 270 V.Power Factor more Six Thousand Nine
13 22.00 than 0.95 THD < 10 % CCT 3000 K Io 5700K Uniformity ratio >0.45 6981.00 Hundred and Eight one Ea.
Luminhire efficacy* 100 lumens/wall l ED driver efficiency > 85 %( Only
fittings required LM 79 & LM 80 cenificates)(NOTE Below description
have shown ranges ol Wattage capacity of LED fittings The Engineer
incharge may select any wattage capacity between the ranges
shown.) (A) Street Lignt (IP-65), Surge protection -4KV integral and
.Light must have 440VAC line supply with over- voltage protection (iii)
Above 60 to 90 watts Cat-lll
Qty. Description Rate Unit Amount
1 2 3 In Words 5
Supplying and erecting Flexible PVC insulated multi strand multi core
14 220.00 1 1 kv grade ISI marked copper wires of following size to be erected 85.00 Eighty Five Only Mtr.
as directed (h) 2.50 Sq mm 3 core round PVC sheathed
Providing and erecting XLPE IS 7098)(1)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1 1 KV to be laid on wall
15 420.00 160.00 One Hundred Sixty Only Mtr.
with necessary clamps or in existing trench / pipe ol loilowmg size of
cables (C) 4 core 10 Sq mm
Making french in Hard Murrum / Tar Road of suitable width of 90 cm
nr required depth for laving any size of cable or locating fault an over
16 370.00 72.00 Seventy Two Only Mtr.
the run and back lilting the same and making the surface as normal
providing and erecting Miniature circut breaker single pole 6A to 25A
suitable to operate on 240 VAC systpm and having breaking capacity
17 22.00 130.00 One Hundred Thirty Only Ea.
10 KA to be erected in existing box confirming to IS 8028/1996 with
ISI Mark Cat III
Providing and erecting Pipe type earthing having 150 cms. long and
2.5 cms dia galvanised iron pipe with coupling and buch buned in
18 11.00 430.00 Four Hundred Thirty Only Ea.
specially prepared earth pit complete with necessary 8 SWG earth
19 11.00 For using salt and charcoal/coke as required tor pipe type earthing 200.00 Two Hundred Only Ea.
Providing and fixing heavy duty flange type brass cable gland with
rubber ring for PVC insulated armoured cable complete with out
20 22.00 43.00 Fourty Three only Ea.
going tails, insulating tape etc for following size of cables (C) 2 to
Solder less crimping type Aluminium lugs conforming to IS suitable
for cable ol following size evenly crimped with high pressure tool &
21 90.00 connected to switchgear terminals with btass/cadmium plated nut 14.00 Fourteen Only Ea.
bolts hi an appioved manner (B)
Supplying and erecting B class Galvanized iron pipe having smooth
finished bore ol the pipe on both ends erected nuts and bolts along Three Hundred Eighty
the pole / wall shaping the pipe as per site requirement Pipe cia as Only
following (D) 50 mm dia
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylenetconformmg to IS 14930 II )with necessary
23 370.00 connecting accessories of same material at requited depth in existing 72.00 Seventy Two Only Mtr.
trench for laying of cable below ground / road surface for enclosing
cable (A)50 mm outer dia
Supplying & erecting approved make SMC press moulded composite
FRP loop-in, loop-out approx 2mm thick box complete with Bakelite
connector strip 5way(3P+N+F) DIN rail for mounting mob H hinged
One Thousand and Fifty
24 11.00 doors as pei requirement having locking arrangements with mounting 1050.00
clamp with nuts bolls & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box (A) 300mm x
200mm x 100mm [deep]
I / We am / are willing to carry out the work at …………….% below / above ( Should be written in figure and words ) of the tender
Tender amount Rs…………………. Tender amount Rs………………….
Add…….% above Rs…………………. Less…….% below Rs………………….
Net in words Rs……………….... Net in words Rs………………....
Credit for Dismental material and Recovery (Fix Deduction) Rs0 (RA BILL)
1 The Contractor Shall Exhibit a board with detailed Specification and details of work as directed by the Engineer-in-Charge for which no extra
2 The Labour cess will be deducted as per prevailing rules i.e.1% of the work done.
3 GST and Income tax TDS will be deducted as a source while making payments of bills.
4 In all R.C.C.Items in Rate Analysis Standard Cement Consumption has been taken as per GOVT.G.R.PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R.therefore in R.C.C. items where there is a changes as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Signature of Contractor
Vadnagar Nagarpalika
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
00_Vadnagar_TITLE.doc
DOC
01_Vadnagar_Pg 2 to 6.doc
DOC
02_Vadnagar_Pg 7 to 49 Tender B2 Form.doc
DOC
03_Vadnagar_Pg 50 to 54.DOC
DOC
04_Vadnagar_Pg 55 to 58.doc
DOC
05_Vadnagar_Pg 59 to 60.DOC
DOC
05 Material spesification.pdf
05_Building Specification.pdf
05_Electrification Specification Work.pdf
05_Plumbing and Sanitation.pdf
ttached with DTP_SBD.pdf
PQ pages to be attached.pdf
Schedule -B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].