SE CIVIL JODHPUR
NPH Jodhpur
R and M of Residential Building 7 Nos. F Type Qtrs., 8 Nos. G Type Qtrs. and 8 Nos. H Type Qtrs. and Boundary wall at NPH Colony Premises, Jodhpur
2026_RRVPN_543957_7
NIT No.24 (2025-26) SE CIVIL RVPN JODHPUR
Open Tender
Civil Works
180 days
NPH Colony Premises
Tender document ,fees Registration Certificate, GST Registration Certificate, etc.
2 documents required · 2 mandatory
₹1,180
AO T and C RRVPNL JODHPUR
₹33,680
Yes
7 Apr 2026
6 Mar 2026
17 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
(B-5/5.8.3) Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand)
(B-7/7.12) Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
(B-7/7.13) Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
(B-8/8.6.8) P&F wood paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clearstory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured ) paneling for paneled and glazed shutter 25mm to 40mm thick, wire gauge 24 gauge 14 mesh of IS designation 85 gauge of dia 0.56mm
(B-8/8.4.2.3-8.11) Providing and fixing fully panelled/partly panelled/ double leaf shutter frames for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :30 mm thick Shesham wood grade I Deduct for providing Single leaf shutter instead of double leaf.
(B-8/8.13.2.1) Providing &Fixing External Grade board solid core single leaf flush door shutters IS 2202-67 marked using Phenol formal dehydreresin in glue both sides with approved steel fittings complete as per Annexure A 30mm thick commercial veneer both side
(B-9/9.5) Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
(B-12/12.3.2) Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish 20mm thick.
(B-12/12.37.2a) Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding old work (one or more coats) including scrapping surface necessary repairs colour change
(B-12/12.46.2) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade one or more coats on old work
(B-12/12.43.2) Painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shed with two or more coats including sand papering, prime coat, making smooth surface with cement based putty etc complete in all respect old work
(B-13/13.1) Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
(B-12/12.22.1) Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)
(B-13/13.4.1) Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm
(B-13/13.12) Repair of stone masonary in cemnt sand mortar 1:6 with old and stone
(B-13/13.15) Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc complete in all respects
(B-13/13.23) Repair of existing steel glazed doors, windows and ventilator, MS Sheet door, garge doors, compound wall gate etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete
(B-13/13.24) Labour charges for repair to door/window without using any material such as applying randha (finishing) tightening of bolts & screw etc
(B-10/10.17.1) Grading roof for water proofing treatment with water proffing compound cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
(B-10/10.22) providing gola 75x75 mm in cement concrete 1:2:4(1cement :2coarse sand :4stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3(1cement :3fine sand) as per standard design
(B-13/13.33.c.ii) Repair of door, window shutters including cost of material and labour for change of damaged aldrop of mild steel 8" long x10mm dia
(B-13/13.33.d.i) Repair of door, window shutters including cost of material and labour for change of damaged stopper of aluminium with single rubber gutka
(S-1/1.2.2) P & F Indian type white glazed vitreous China Ist quality W.C Orissa Pan IS 2556 mark with 100mm vitreous China P or S trap incl. Cutting and making good the wall and floor size 580 x 440 mm
(S-1/1.3) P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
(S-1/1.7.2) P&F water closet seat covers with brass hinges complete solid PVC ISI marked Gr I white of EWC
(S-1/1.59) P&F Jet spray for water closet with C.P. copper tube flange of approved make.
(S-1/1.20.2) P&F low level flushing cistern of 10 Ltr cap. IS 2556 mark of appd,. Make with complete fitting CI brackets duly painted brass ball cock with ball IS 1703 mark complete incl. Cutting and making good the wall PVC with PVC bend as per IS 7231
(S-1/1.36.3) P&F WVC wash basin Ist quality IS 2556 mark of appd,. Make with CI brackets duly painted 1 No. 15mm C.P. pillar cock IS 8934 mark & 32mm C.P. brass waste coupling of appd,. Make 25mm G.I. waste pipe complete incl. Cutting and making good the wall size 550x400mm
(S-2/2.38.2) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)20mm nominal size
(S-2/2.38.3) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)25 mm nominal size
(S-2/2.39.3) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). 25 mm nominal size
(S-2/2.7.1) P&F bib cock IS 8931 mark superior quality of appd. Make Brass bib cock 15mmdia 400 Gms.
(S-2/2.7.3) P&F bib cock IS 8931 mark superior quality of appd. Make C.P. brass bib cock 15mmdia nominal bore
(S-2/2.7.4) P&F bib cock IS 8931 mark superior quality of appd. Make C.P. brass long body 15mm dia Weight not less than 690 Gram
(S-2/2.13.2) P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipe with C.P. Brass nuts upto length, 370mm
(S-2/2.11.2) P&F ball cock IS 1703 mark with rod & PVC ball complete brass Weight 400 Gram 15mm dia
(S-2/2.15.1) P&F full way valve IS 778 mark or wheel valve of approved Make gun metal 15mm Nominal Bore
(S-2/2.15.3) P&F full way valve IS 778 mark or wheel valve of approved Make gun metal 25mm Nominal Bore
(S-1/1.43.2) P&F waste pipe with all fitting P.V.C with PVC nut 32 mm
(S-3/3.16.3) P&F rigid PVC pipe (IS 4985 mark) class IInd /4 Kg P.SqCM ) approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant 110mm dia
(S-2/2.12.1) P&F inlet connection (Angle valves) superior quality of approved make for wash basin Gyser etc . C.P. inlet connection 15mm brass (IS 8931 marked)
(S-1/1.45.1) P&F looking mirrors with PVC frame of appd. Quality Atul or equivalent size 500x400mm
(S-3/3.19.1) Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M
(S-3/3.17.9) P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 110 mm dia Bend : 87.5
(S-3/3.17.12) P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 110 mm dia vent cowel
(S-3/3.17.8) P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 110 mm dia Bend (45 Dg)
(S-1/1.60) Providing & fixing C.P. flange for 15mm dia taps
(S-1/1.55.2) P&F bath shower of approved quality / make C.P. brass of heavy and superior quality 150mm
(S-1/1.54.1) P&F shower arm 15mm dia of approved quality make C.P. brass heavy & superior quality 150mm projection
(S-2/2.8.5) P&F stop cock IS 8931 mark superior quality & of approved make C.P. brass concealed stop cock 15mm
(S-1/1.38.9.2) P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :1.0 mm thick Salem stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. 22 x 18 x7 .
(S-2/2.26.2) P&F PVC storage tank IS 12701 marked indicating the BIS license No. of approved make with cover 25mm dia 1 M long GI over flow pipe & 25 CM long wash out pipe with plug & socket incl. Making conn. Etc. complete of appd. Design 300 Ltr capacity
(S-2/2.26.3) P&F PVC storage tank IS 12701 marked indicating the BIS license No. of approved make with cover 25mm dia 1 M long GI over flow pipe & 25 CM long wash out pipe with plug & socket incl. Making conn. Etc. complete of appd. Design 500 Ltr capacity
(S-1/1.48.2) P&F grating of approved quality stainless steel sheet heavy quality of approved make 125 mm
(S-2/2.6.1) P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make:C.P. Pillar cock, 15 mm dia nominal bore
(S-1/1.47.2) P&F towel rail or ring of appd. Quality make C.P. brass towel rail elbow type with concealed screw size 600mm heavy duty
(S-1/1.47.8) P&F towel rail or ring of appd. Quality / make C.P. Brass Towel Ring revolving type
(S-1/1.52.2) P&F soap dish or tray of appd,. Quality make IS 2556 marked C.P.Brass heavy and superior quality.
(S-3/3.28) Emptying of septic tank soakage well etc by disposting or sludge upto 50mtr lead & taking out sewage incl cleaning of site
(G-4/4.1.7) Carriage of earth, sand, lime, morrum, manure or sludge. Lead 1.0km
(B-11/11.18.2) Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm
(B-3/3.8) Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
(B-7/7.3.3) Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Keseriaji/ Abu Ambaji (Green Marble) Above 3601 Cm2 Slabs
(B-12/12.5) 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)
(B-12/12.62) Lettering with black japan paint of appd brand and manufacture
(B-15/15.24.4) Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 100x 75mm
(B-15/15.25.1) Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry:Size 100 x 75mm.
(E-1/1.1.1) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Short point (up to 3 mtr.)
(E-1/1.1.2) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Medium point (up to 6 mtr.)
(E-1/1.1.2) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Long Point (up to 10 mtr.)
(E-1/1.3.1) Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR On board
(E-4/4.1.1) Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1 x 1.5 sq.mm
(E-4/4.1.6) Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 2.5 sq.mm
(E-4/4.1.11) Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 4.0 sq.mm
(E-7/7.4) Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-17/17.2.2) Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
(E-06/6.1.1.2) Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:6A to 32A rating
(E-06/6.2.1.2) Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:Double pole isolator 63 A rating
(E-06/6.10.1.1) Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:Metal door (single phase) IK-09 and IP-43 with Metal end box 4 Way (4+2)
(E-7/7.12) Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-7/7.13) Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-7/7.20) Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-18/18.10.1) Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Minimum lumen output 2500 lm Post top Luminarie
(E-15/15.11.2) Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .300 mm sweep
(E-11/11.2.2.1) Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq. mm 2 core
(E-7/7.1) P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(E-7/7.10) Providing & Fixing of of 3/5 pin 6 amp. flush type non modular socket made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(B-9/9.28.1) Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable.
(B-9/9.26) Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
(B-9/9.27) Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
E-01/1.4.1 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:20mm
(B-13/13.13) Repair to brick masonary in cement sand mortar 1:6 with new brick.
(B-6/6.15) Providing and fixing horizontal chajja of Red/ White sand stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.
(B-12/12.35.3) Colour washing of all shades to give an even shade including all scaffolding Old work (one or more coats) with whiting with a base coat of white washing including scrapping old surface.:
(S-3/3.44.2) Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia
(S-3/3.3.1) Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe)100mm dia S.W. pipe
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tenderdoc.pdf
Tender Documents • 0.37 MB
FinalContractAggrementfinal-1.pdf
Other Document • 2.20 MB
BOQ_970122.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid