Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-Finance 0 BANI MOHAN ROAD SAROJNI NAGAR VILL AND POST TIRWA BANTHRA LUCKNOW UTTAR PRADESH 226401 UDYAM UP 50 0138308 | LUCKNOW | UTTAR PRADESH | 226401 | ₹10.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹10.9 LRejected-Finance | ₹10.9 L | L2 | Rejected-Finance L2 |
Tender Value
₹11.0 L
EMD Value
₹1.1 L
Closing Date
28 Apr 2026, 12:00 pmClosed
SE 47th(E/M) Circle PWD Moradabad
Office of the SE 47th(E/M) Circle PWD Moradabad
Janpad Amroha me navnirmit guest house me vatanukulit sanyantro, geaser, inverter battery, sound system etyaadi upkarno ki esthapna ka karya
2026_CEEMP_1140341_1
461/3WE(MBD)-47/2026 Dt. 09.04.2026
Open Tender
Electrical Works
180 days
Amroha
As par NIT
2 documents required · 2 mandatory
₹854
Executive Engineer E/M Division PWD Moradabad
₹1.1 L
As per NIT
13 May 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
23 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | HI - WALL SPLIT SYSTEM
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only
1.5 TR with 5 Star BEE Rating | - | No. | - | - | BI01010001010000000000000515BI0100001128 |
| 2 | HI - WALL SPLIT SYSTEMS
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only
2.0 TR with 5 Star BEE Rating | - | No. | - | - | BI01010001010000000000000515BI0100001129 |
| 3 | Supply and Fixing of 5 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130-300Range) with Copper Winding | - | No. | - | - | BI01010001010000000000000515BI0100001130 |
| 4 | Supply and Fixing of 4 KVAVoltage Stablizer for Air Conditioner Upto 1.5TR (130-300Range) with Copper Winding | - | No. | - | - | BI01010001010000000000000515BI0100001131 |
| 5 | SITC of suction / Discharge copper pipe line in Split AC unit 1.5 Ton capacity including brazing, nitrile rubber insulation 9mm thick Class 'O' etc complete 1/4'' (6.4mm) and 1/2'' (12.70mm) | - | Mtr | - | - | BI01010001010000000000000515BI0100001132 |
| 6 | SITC of suction / Discharge copper pipe line in Split AC unit 2.0 Ton capacity including brazing, nitrile rubber insulation 9mm thick Class 'O' etc complete 3/8'' (9.5mm) and 5/8'' (15.90mm) | - | Mtr | - | - | BI01010001010000000000000515BI0100001133 |
| 7 | S/I of heavy duty PVC plastic braided 20mm OD Flexuible pipe for condenced water drain with clipping accessories complete in all respect | - | Mtr | - | - | BI01010001010000000000000515BI0100001134 |
| 8 | Supply & fixing of 2.5Sqmm 3 core round coper cable for AC Connecting Indoor/outdoor unit | - | Mtr | - | - | BI01010001010000000000000515BI0100001135 |
| 9 | Supply and fixing of outdoor unit stand for Split AC. | - | No. | - | - | BI01010001010000000000000515BI0100001136 |
| 10 | Supply and fixing of 150 Ah battery | - | No. | - | - | BI01010001010000000000000515BI0100001137 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
T1Amroha.pdf
Tender Documents • 7.10 MB
AmrohaScheduleC.pdf
Additional Documents • 1.15 MB
BOQ_2129531.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid