Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | ₹10.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹10.9 LRejected-Finance | ₹10.9 L | L2 | Rejected-Finance L2 |
Tender Value
₹11.0 L
EMD Value
₹1.1 L
Closing Date
28 Apr 2026, 12:00 pmClosed
SE 47th(E/M) Circle PWD Moradabad
Office of the SE 47th(E/M) Circle PWD Moradabad
Janpad Amroha me navnirmit guest house me vatanukulit sanyantro, geaser, inverter battery, sound system etyaadi upkarno ki esthapna ka karya
2026_CEEMP_1140341_1
461/3WE(MBD)-47/2026 Dt. 09.04.2026
Open Tender
Electrical Works
Percentage
180 days
Amroha
As par NIT
2 documents required · 2 mandatory
₹854
Executive Engineer E/M Division PWD Moradabad
₹1.1 L
As per NIT
13 May 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
28 Apr 2026
22 Apr 2026
23 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | HI - WALL SPLIT SYSTEM
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only
1.5 TR with 5 Star BEE Rating | - | No. | - | - |
| 2 | HI - WALL SPLIT SYSTEMS
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only
2.0 TR with 5 Star BEE Rating | - | No. | - | - |
| 3 | Supply and Fixing of 5 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130-300Range) with Copper Winding | - | No. | - | - |
| 4 | Supply and Fixing of 4 KVAVoltage Stablizer for Air Conditioner Upto 1.5TR (130-300Range) with Copper Winding | - | No. | - | - |
| 5 | SITC of suction / Discharge copper pipe line in Split AC unit 1.5 Ton capacity including brazing, nitrile rubber insulation 9mm thick Class 'O' etc complete 1/4'' (6.4mm) and 1/2'' (12.70mm) | - | Mtr | - | - |
| 6 | SITC of suction / Discharge copper pipe line in Split AC unit 2.0 Ton capacity including brazing, nitrile rubber insulation 9mm thick Class 'O' etc complete 3/8'' (9.5mm) and 5/8'' (15.90mm) | - | Mtr | - | - |
| 7 | S/I of heavy duty PVC plastic braided 20mm OD Flexuible pipe for condenced water drain with clipping accessories complete in all respect | - | Mtr | - | - |
| 8 | Supply & fixing of 2.5Sqmm 3 core round coper cable for AC Connecting Indoor/outdoor unit | - | Mtr | - | - |
| 9 | Supply and fixing of outdoor unit stand for Split AC. | - | No. | - | - |
| 10 | Supply and fixing of 150 Ah battery | - | No. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
T1Amroha.pdf
Tender Documents • 7.10 MB
AmrohaScheduleC.pdf
Additional Documents • 1.15 MB
BOQ_2129531.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].