| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L1 | Accepted-AOC Lowest reasonable bid accepted | |
| 2 | L2₹9.1 L+₹2.3 L (33.7%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
5 Jan 2021, 6:00 pmClosed
CWE WELLINGTON
Headquarters, Commander Works Engineers, Military Engineer Services Ministry of defence Wellington, Barraks-Post, The Nilgiris, PIN 643231
CLEANING OF UG SUMPS AND OVER HEAD TANKS, REPAIRS/MAINTENANCE OF GI PIPE LINES, VALVES, MOTORS ETC, AND PERIODICAL SERVICES TO OVER HEAD TANK STORAGE UNDER UNDER AGE (I) TRICHY.
2020_MES_394221_2
84508/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
TRICHY
E Class a ii Category
6 documents required · 6 mandatory
₹500
AGE (I) TRICHY
₹15,000
Yes
11 Feb 2021
14 Dec 2020
7 Jan 2021
14 Dec 2020
5 Jan 2021
22 Dec 2020
Amount
Excavation in trenches not exceeding 1.5 m in depth and not exceeding 1.5 m in depth in hard dense soil for taking out / laying of pipe line complete all as specified and directed.
Returning, filling in with excavated soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
Taking out / up / down from trenches /walls /floors galvanised steel tubings and connections of following sizes complete all as specified and directed.
Bore of pipe 15 mm dia.
Bore of pipe 20 mm dia.
Bore of pipe 25 mm dia.
Bore of pipe 40 / 50mm dia.
Bore of pipe 80mm dia.
Supply and laying in trenches GI tubings medium grade with screwed and socket joints together with all galvanised steel fittings such as sockets, elbows, bends, tees, reducers, short pieces, unions, caps, plugs etc. including clamps, connection, cutting, screwing , drilling etc upto 100 mm dia pipe all as specified and directed including connections of following sizes. Note: 1. Excavation and earth work will be measured and paid separately. 2. Suitable size of Union will be provided at all branches tees joints and at a maximum distance of 30 RM of straight pipe and rates are deemed to be included in the rate quoted above for ease in maintenance.
Bore of pipe 20 mm dia.
Bore of pipe 25 mm dia.
Bore of pipe 40 mm dia.
Bore of pipe 50 mm dia.
Bore of pipe 80 mm dia.
Supply and fixing on walls, floors, roof, ceilings galvanised steel tubings medium grade with screwed and socket joints together with all galvanised steel fittings such as sockets, elbows, bends, tees, reducers, short pieces, unions, caps, plugs etc including clamps and connections of following sizes complete all as specified and directed. Note : Suitable size of union will be provided at all branches tees joints and at a maximum distance of 30 RM of straight pipe and rates are deemed to be included in the rate quoted above for ease in maintenance.
Bore of pipe 15 mm dia.
Bore of pipe 20 mm dia.
Bore of pipe 25 mm dia.
Bore of pipe 80 mm dia.
S&F gun metal globe or gate valve, heavy duty conforming to IS-778 with iron wheel head screwed both ends suitable for fixing to GI pipe including dismantling taking out old unserviciable gun metal globe or gate valve of following sizes, complete all as specified and directed :
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S&F pressure gauge with chromium plated brass cock and tube range up to 7 Kg / sq cm for pump set including all accessories required to be fixed on CI / GI pipe lines including taking out old unserviciable pressure gauge complete all as specified and directed.
Supply and replacement of star delta starter fully automatic suitable for electric pump set motors 10 HP capacity 3 phase 415volts, comprising of main star delta contactor, timer, overload relay complete including taking out old unserviciable starter complete all as specified and directed. Note : The rate quoted above are deemed to be included the cost of minor alteration to the panel for fixing of above starter complete.
S&F foot valve ball type heavy duty suitable for 100 mm dia pipe line including replacement of old unserviciable foot valve any type and make from suction pipe of pump set all as per the direction of Engineer in charge complete all as specified and directed.
All as per item No 11.00 but for 80mm bore complete all as specified and directed.
All as per item No 11.00 but for 50mm bore complete all as specified and directed.
M&L for construction of valve pit chamber of size 900mm x 900 mm x 900 mm (internal size) with 3.15 mm thick MS sheet cover and angle iron 50 x50 x6 mm thick fame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation removal of surplus soil to a distance not exceeding 50 mtr returning filling in PCC 1:3:6 type C2 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:3:6 type C1 in copping, Plastering in cm 1:4 and 75 mm thick hard core below foundation etc including dismantling valve pit chamber complete all as specified and directed.
M&L for construction of valve pit chamber of size 600mm x600 mm x600 mm (internal size) with 3.15 mm thick MS sheet cover and angle iron 50 x50 x6 mm thick fame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation removal of surplus soil to a distance not exceeding 50 mtr returning filling in PCC 1:3:6 type C2 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:3:6 type C1 in copping, Plastering in cm 1:4 and 75 mm thick hard core below foundation etc including dismantling valve pit chamber complete all as specified and directed.
S&F non return valve flanged with by pass arrangements heavy duty class -I 80mm bore conforming to IS including rubber gaskets, bolts, nuts, and washers and dismantling taking out old unserviceable NRV including cutting unscrewing old nut bolts complete all as specified and directed.
S&F and testing 80mm bore sluice valve flanged and drilled both ends CI body, heavy duty, class PN 1:6 gun metal spindle conforming to IS 14846 including jointing with and including rubber gaskets, bolts, nuts, and washers complete and dismantling taking out old unserviciable sluice valve including cutting unscrewing old nut bolts complete all as specified and directed.
S&F and testing 100 mm bore sluice valve flanged and drilled both ends CI body, heavy duty, class PN 1:6 gun metal spindle conforming to IS 14846 including jointing with and including rubber gaskets, bolts, nuts, and washers complete and dismantling taking out old unserviciable sluice valve including cutting unscrewing old nut bolts complete all as specified and directed.
Dismantling the mono block pump set of 10 HP cap 3 phase & segregating to its parts for repairs and M & L for rewinding motor with super enameled copper wire of same size/gauge wire and turn of old burnt out wire with insulating material including varnishing , turning and polishing to the shaft and / or rotor, including replacement of suitable bearing etc complete & refixing motor after completion of work including testing of motor complete all as specified and directed.
Taking out/lowering the submersible pump set upto 5/7.5 HP from deep bore well with connected cable and column pipes and disconnecting the cable for removing the submersible pump set for carrying out minor repairs and re-assembling column socket pipe end and testing and commissioning of pump set after repairs including rectification of any leakage to entire satisfaction of Engineer -in -charge complete all as specified and directed.
Dismantling the submersible pump set upto 5 HP by separating pumps and motor opening machineries fully for carryout required repairs to pump/ motor by machines and reassembling after replacing all worn out spare parts as mentioned here in after, cleaning and refixing with motors, coupling etc, & testing complete all as specified and directed at site.
Rewinding of AC three phase induction motor upto 5 HP(Submersible motor) including cutting of burnt winding ,cleaning of starter slots ,cleaning & bleaching of motor and rewinding with existing size gauge of PVC insulated copper wire water proof winding cable and including servicing of pumps complete all as directed by Engineer-in- charge complete all as specified and directed.
S&F the following parts for item No 22.00 complete all as specified and directed.
Thrust plate.
Winding protection set.
Motor bearing.
Impeller.
Neck ring.
Supply and connect PVC insulated PVC sheathed submersible multi stranded copper conductor flat cable 3 core 6 sqmm 1100 volts grade ISI marked including disconnecting dismantling taking out old unserviceable cable from LT panel to pump set all as directed and specified by engineer in charge complete all as specified and directed.
All all as per item No 24.00 above but 10.00 Sq.mm 3.core.
M&L for cement concrete 1:2:4, type B1, using 20 mm graded stone aggregate as in foundation base for mono block pump set complete all as specified and directed.
M&L for cleaning of RCC UG water storage sump / ground level tank by pumping out dirty water & removing all sludge, dirt silt etc from walls and floor of the tank & treating the wall with bleaching powder, rubbing scrapping walls and floor with the wire brushes and taking out all silt, sludge and dirt from the sump and depositing to a distance up to 50 meter complete all as directed by engineer in charge after primary cleaning of the empty sump and same shall be cleaned further with mixture of fresh water and potassium permanganate at the rate of two percent with water & washing the sump shall be continued till water stored in the tank looks clear and then applying two coats of lime wash inside the sump and writing the date of cleaning and capacity of sump of size of letter 4" with synthetic enamel paint (white) distinctively for following capacity complete all as specified and directed:-
30000 liters capacity at Kajamalai.
75000 liters capacity at Reynolds road ( drinking water ).
22700 liters capacity at Reynolds road ( bore well water ).
112000 liters capacity at Alexandriya road.
22700 liters capacity at Garuda lines (Sump 1 & 2).
10000 Glns capacity at Mannarpuram.
M&L for cleaning of RCC overhead water storage tank by removing all sludge, dirt silt etc from walls and floor of the tank & treating the wall with bleaching powder, rubbing scrapping walls and floor with the wire brushes and taking out all silt, sludge and dirt from the tank and depositing to a distance up to 50 meter complete all as directed by engineer in charge, after primary cleaning of the empty tank and same shall be cleaned further with mixture of fresh water and potassium permanganate at the rate of two percent with water & washing the tank shall be continued till water stored in the tank looks clear and then applying two coats of lime wash inside the sump and writing the date of cleaning and capacity of tank of size of letter 4" with synthetic enamel paint (white) distinctively including preparation of base for following capacity complete all as specified and directed:-
60000 liters capacity at Alexandriya road.
5000 gallons capacity at Mannarpuram upto 50 m staging.
10000 gallons capacity at garuda line upto 50 m staging.
48000 liters capacity at garuda line upto 30 m staging.
M&L for cleaning of PVC service water tank by using following six stage mechanised cleaning process of below given capacities . (a) Sucking out of water from existing PVC tank by using pump. (b) Sucking out of sludge and mud from the tank by using sludge pump. (c) High pressure cleaning of walls & ceilings of water tank using 150 Bar pressure, jet cleaner which rid of the walls off calcinations, algae and all contamination. (d) Cleaning and draining up of tank by using Industrial vacuum cleaner. (e) Antibacterial treatment of internal wall and ceiling of tank by using bio-degradable antibacterial spray. (f) Finally sterilzation and disinfection of tank will be done by using UV radiation developing from UV radiator to kill any suspended bacterial remaining in the tank. Note : (a) After cleaning the tank, date of cleaning will be written on the tank by using stencil. (b) when cleaning tank, float valve should be removed and after completion of cleaning, float valve to be fixed to same tank.
250 ltr capacity.
500 ltr capacity.
750 to1000 ltr capacity.
Taking down RCC cover slab from RCC water tank, cleaning and removing all scale and dirt from RCC water tank exceeding 250 litres capacity and not exceeding 500 litres capacity and from mouth of circulating pipes etc complete all as specified and directed.
All as per item above but exceeding 500 lit but not exceeding 1000 ltr capacity.
M&L preparation of old painted surfaces of pump set of following capacity and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
10 HP, 3 phase, 415 volts, 50 c/s.
7.5 HP, 3 phase, 415 volts, 50 c/s.
5 HP, 3 phase, 415 volts, 50 c/s
S&F tank cover for 500/1000 liters tank threaded type ( male and female assy) along with locking arrangement complete all as specified and directed.
S&F rotational mould polyethylene water storage tank white colour triple layer of capacity 500 liters (cylinder vertical with closed top ) hoisted and fixed in position complete all as specified and directed.
M&L for brickwork with subclass `B' bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete wall surfaces finished even and fair complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
S&F integral aviation light comprising of aluminium housing with polycarbonate enclosure with LED lamps fixed in position on over head tank minimum height 30 meter staging with provisioning of 1.5 sqmm 3 core multi stranded copper conductor cable passing through pvc conduit pipe with all fixing accessories including taking down old unserviceable light fitting complete all as specified and directed.
S&F dual source digital electric meter (Multi functional meter) LED display automatically measured voltage current, frequency, PF KW, KVA etc 1/5 amps, 415 volts, to be fixed on existing panel board complete all as specified and directed.
S&F heating coil element 2 KW capacity for solar water tank 230 volt, 50 HZ all as specified complete all as specified and directed.
S&F re-wirable switch fuse unit triple pole neutral 63 amps 415 volts steel enclosure porcelain fuse carrier & base complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on ceiling surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white washing on ceiling complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white washing on wall complete all as specified and directed.
M&L for preparing old decorated surfaces of walls (plastered or unplastered) including cornices and pillasters and applying one coat of white washing complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and steel based materials of any description not otherwise described exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Supply in replacement auxiliary contactor MNX 18 of suitable for 5 HP induction motors complete all as specified and as directed.
Supply in replacement overload relay contactor mounting type capacity suitable for 5 HP induction motors complete all as specified and directed.
Supply and replacement of direct on line submersible starter suitable for 5 HP three phase submersible motor complete all as specified and directed.
M&L for CI fittings upto 150 mm bore of any type, radius and angles tapers any types such as bends, tee, tail pieces all sockets or spigot and flanged type complete all as specified and directed.
Supply and laying unplasticised PVC pipes of pressure rating 10 kgf/cm² of size 20 mm bore fixed complete to walls, ceiling or in floors including with all fittings such as ends, elbows, unions, tees, reducing tees, adaptors, sockets, plugs, hose clip and fixing saddles, wall clips, hooks, protective mild steel tubes sleeves and screws complete all as specified and directed.
All as item No 52 above but here in before 25 mm bore.
All as item No 52 above but here in before 50 mm bore.
Supply and replacement of on load change over switch 100 A 4-pole 415 volts complete all as specified and directed.
Supply and replacement of pump house sign board made of angle iron (25x25 mm 6 mm thick) frame of size 100cm x60 cm including MS sheet 3 mm thick and both sides are MS pipe 50 mm bore 2.5 metre long (0.5 m grouting in ground and 2 metre above the ground)including excavation, removing and PCC 1:4:8, C-2 using 40mm graded stone aggregate and two coats of synthetic enamel paint , blue colour paint over a coat of red oxide and writing letters using synthetic enamel white colour paint (pump house No1 Alexandriya road, pump house No 2 Clive line, pump house No 3 Reynolds road and pump house No 4 Mannarpuram) complete all as specified and directed.
S&F OH tank and UG sump man hole cover made out of mild steel 3.15 mm thick sheets and frame 25 mm angle 6 mm thick including handle, hinges and locking arrangement complete all as specified and directed.
Supply and replacement of unserviceable ON and OFF push button complete all as specified and directed.
Supply and replacement of single phase preventer complete all as specified and directed.
Taking down old unserviceable LT cable, supply and laying in trenches /pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing of XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, 6 Sqmm 2 core all as specified directed by Engineer In charge. Note : Excavation and earth work, sand, pipe and bricks will be measured and paid separately.
M&L for sand cushioning to PVC cable with sand and punning to provide required for protection of cable complete all as specified and directed.
Supply and laying burnt bricks, sub class B of old size laid dry in trenches for cable protection complete all as specified and directed.
S&F 40mm bore, GI tubing, light grade of following size for protection of cable in trenches/on pole complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, top edge of the plate not less then 1.5M below nominal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts and cheek nut and washer of galvanised iron including GI protection pipe and watering pipe all as shown in electrical plate No 5 of SSR Pt 1 including connection with O/H conductor on poles / main switch board / Panel / FPB all as specified or indicated including testing on completion including taking and/removing old u/s earthing from existing location complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, top edge of the plate not less then 1.5M below nominal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts and cheek nut and washer of galvanised iron including GI protection pipe and watering pipe all as shown in electrical plate No 5 of SSR Pt 1 including connection with O/H conductor on poles / main switch board / Panel / FPB all as specified or indicated including testing on completion including taking and/removing old u/s earthing from existing location all as directed by Engr-in-Charge.
al mecho fab
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .