| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.4 CrRejected-Finance | ₹2.4 Cr | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | DULAP SINGH L1 | HIMMAT SINGH RAWAT L2 |
|---|---|---|---|---|---|
| 1.01 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 329.41 | Cum | 220 ₹72,470.20 | 221 ₹72,799.61 |
| 2.01 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). of specified grade -All work upto plinth level excluding the cost of centring and shuttering - by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 75.43 | Cum | 5,772 ₹4.4 L | 5,772 ₹4.4 L |
| 3.01 | Random rubble masonry with Cement mortar 1:6 (1 cement : 6 coarse sand) with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 62.72 | Cum | 6,195 ₹3.9 L | 6,295 ₹3.9 L |
| 4.01 | Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) - All work upto plinth level excluding the cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 82.76 | Cum | 7,665 ₹6.3 L | 7,665 ₹6.3 L |
| 5.01 | Brick work in Cement mortar 1:6 (1 cement : 6 coarse sand) with F.P.S. bricks of class designation 75 in foundation and plinth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 15.48 | Cum | 6,044 ₹93,561.12 | 6,044 ₹93,561.12 |
| 6.01 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 171.84 | Cum | 7,716 ₹13.3 L | 7,716 ₹13.3 L |
| 7.01 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 143.82 | Sqm | 952 ₹1.4 L | 952 ₹1.4 L |
| 8.01 | Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto floor five level work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. excluding cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 59.7 | Cum | 9,197 ₹5.5 L | 9,197 ₹5.5 L |
| 9.01 | Reinforced cement concrete work in beams, suspended floors, roofs having
slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain
window sills, staircases and spiral stair cases above plinth level up to
floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse
sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 277.25 | Cum | 9,750 ₹27.0 L | 9,750 ₹27.0 L |
| 10.01 | Centring and shuttering for Foundations, footings, bases of columns, etc. including strutting,ropping etc. and removal of form for mass concrete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item | 91.46 | Sqm | 332 ₹30,364.72 | 332 ₹30,364.72 |
Tender Value
₹2.8 Cr
EMD Value
₹5.5 L
Closing Date
19 Jan 2026, 12:30 pmClosed
S.E R.W.D Circle Pauri
Superintending Engineer Rural Works Department Circle Pauri Tehsil Road Near Gas agency Pauri
Construction work of Community Hall and Parking in Semtop under Nanda Devi Raj Jat Yatra Block Karanprayag Distt. Chamoli
2025_RES_90445_1
1108/RWD/T.I/2025-26
Open Tender
Civil Works - Buildings
450 days
karanprayag
Technical Qualification as per SBD
3 documents required · 3 mandatory
₹5,900
As per attched SBD
₹5.5 L
S.E R.W.D Circle Pauri
8 Apr 2026
31 Dec 2025
19 Jan 2026
31 Dec 2025
19 Jan 2026
31 Dec 2025
8 Jan 2026
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). of specified grade -All work upto plinth level excluding the cost of centring and shuttering - by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Random rubble masonry with Cement mortar 1:6 (1 cement : 6 coarse sand) with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) - All work upto plinth level excluding the cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work in Cement mortar 1:6 (1 cement : 6 coarse sand) with F.P.S. bricks of class designation 75 in foundation and plinth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto floor five level work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. excluding cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centring and shuttering for Foundations, footings, bases of columns, etc. including strutting,ropping etc. and removal of form for mass concrete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts. including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Suspended floors, roofs, landings, balconies and access platform. including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
15 mm cement plaster on rough side of single or half brick wall of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers .including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete withUdaipur green marble
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile C 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete
Providing and fixing M.S. Tubular frames for doors, windows, ventilator sand cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, includin cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Renewing glass panes, with putty and nails wherever necessary Float glass panes of thickness 4 mm as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.With 12 mm mild steel U beading. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc 200x10 mm. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc 100 mm . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (75 mm diameter ) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (110 mm diameter ) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Coupler 75 mm Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
Coupler 110 mm Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
Single tee without door 75x75x75 mm Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
Single tee without door 110x110x110 mm Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
75 mm bend Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
110 mm bend Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories
Providing and fixing 15 mm nominal bore ball valve (brass) of approved quality complete. High or low pressure with plastic floats. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing white vitreous china pedestal type water closet (European type) W.C. pan with ISI marked white solid plastic seat and lid. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing P.V.C. waste pipe (Flexible pipe 32mm dia) for sink or wash basin including P.V.C. as per direction of Engineer -in- charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (INTERNAL work) 15 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
15 mm dia nominal bore Providing and fixing G.I. Pipes complete with G.I. fittings including trenching and refilling etc (External)
Providing and fixing G.I. Pipes complete with G.I. fittings including trenching and refilling etc (External) 20 mm dia nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing and fixing brass stop cock of approved quality 15 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finished with a floating coat of neat cement complete as per standard design : as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given (With F.P.S. bricks)
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter
soil Excavation in Hilly Areas in by mechanical means Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 soil
ordinary Rock 40% Excavation in Hilly Areas in by mechanical means Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause ordinary Rock 40%
hard rock Excavation in Hilly Areas in by mechanical means Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause
Removal of Unsuitable Soil with Disposal upto 1000 m Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Hand Packed stone filling in back of wallls including cost of all materials,royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:2:4 (Hand mixed)
Providing and laying of wire crates 3.00x1.50x1.50 in size with GI wire conforming to IS: 280 & IS:4826 in 150mm x 150mm mesh laid with stone boulders. as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_107185.pdf
BOQ Comparative Chart
xlsx
finsummary_107185.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
Tendernotice_2.pdf
PDF • 2.32 MB
BOQ_107185.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid