| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2₹35.9 L+₹1.6 L (4.77%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L2 | Rejected-Finance Other than the lowest bidder | |
| 3 | L3₹36.5 L+₹2.2 L (6.48%)Rejected-Finance | L3 | Rejected-Finance Other than the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹71,700
Closing Date
26 Dec 2019, 6:00 pmClosed
GE AF CHILODA
VAYU SHAKTI NAGAR CHILODA
SPECIAL REPAIR TO CONCERTINA COIL, SNCOs MESS FLOORING, LOGISTIC SECN, WATER PIPE LINE ALONGWITH PROVN OF AC, ACTIVE LIGHTENING ARRESTER AND CERTAIN MAJOR REVENUE/ MINOR WORKS AT AREA B AF STN WADSAR
2019_MES_302144_1
8973/19-20/E8
Open Tender
Miscellaneous Works
Item Rate
182 days
AF STN WADSAR
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE AF CHILODA
₹71,700
Yes
13 Jan 2020
29 Nov 2019
28 Dec 2019
29 Nov 2019
26 Dec 2019
13 Dec 2019
29 Nov 2019 - 13 Dec 2019
Amount
Dismantling structural steel work including doors, gates but excluding framed truss etc.complete.
Dismantling of punched type concertina coil any type or size all as specified and directed.
Demolition of cement concrete(unreinforced) in ground floor and pavings not exceeding 15 cm thickness (below or above ground level) complete.
Demolition of brick work of any description and in any position , built in cement mortar including all quoins, arches, pillers etc.complete.
S&F framed work such as grills, gratings, angle iron, purlin, wind tie etc. with end of bars shouldered and/or riveted or forged into spikes, framed guard bar , barred iron doors, railings, framed work/caging of water tank and similar works conforming to Fe 290, Gde -E-165 including hanging / locking arrangement as gate ,with hooks and pintle hinges, stops, hand-made sliding bolts including welding and fixing etc all as specified and directed.
Fixing only galvanized steel punched type concertina coil of loop dia 1050mm (dia of coil when unstreched) fixed to angle post strut with 3.15 mm dia galvanised MS plain wire complete all as specified and directed.
Supply only galvanised steel punched type concertina coil of 1050mm dia (dia of coil when unstretched with Nos. of circles 50, Nos. of clips 230 with weight 15.60 kg/ coil and recommended and average coverage area is 6 RM/ coil) and fixed to angle iron post/ struts with 3.15mm dia GI wire complete all as specified and as directed.
S&F galvanised, 2 strand, steel barbed wire, 2.24 mm dia, barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of heavy duty galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. Note:- Each line wire shall be measured.
M&L for providing cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) in roof kerbs or mud stop, rounded or chamfered on edges including necessary formwork complete all as specified.
S&F mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other end to be fitted with washers and one hexagonal nut bolt of length exceeding 5.00 cm but not exceeding 10 cm long and one side embedded in concrete posts to fix fencing wire, dia of shank 11 to 15 mm complete.
M&L for brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:6 complete.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of concrete, brick work surfaces including finishing the surfaces even and smooth without using extra cement on internal wall surfaces all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises.
Demolition of stone slabs and tiles of any description, laid bedded and pointed in any mortar complete.
M&L for joint free non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors over and including 15 mm thick screed bed in CM 1:6 etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete.
M & L for vitrified ceramic tiles, 10mm thick light shade (square/ rectangular) polished , area of each tiles not exceeding 0.36 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match , over and including 15mm thick screed bed in CM 1:6 complete.
All as item No. 17.00 above but dark shade tiles on vertical skirting over and including 10 mm thick backing coat of CM 1:4 complete.
M&L for glazed coloured ceramic tiles 350x250x7mm/ 450mm x 300mm x 7mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 as directed.
M&L for granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 10 mm thick rendering in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in CM 1:6 complete.
M&L for 15-18 mm thick machine cut Pre- polished kota stone slab in single piece with round nosing with three numbers of serration as in treads of steps for staircase laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab complete all as specified and as directed by EIC over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for machine cut Pre polished kota stone 16-18 mm thick (single peice in raiser of steps), skirting, dado and pillar laid and jointed with grey cement slurry including cutting and mirror polishing over and including 10 mm thick screed bed in CM 1:3 complete all as specified and directed.
Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc. complete.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of concrete or block masonry, brick work surfaces including finishing the surfaces even and smooth without using extra cement on internal wall surfaces all as specified and directed.
All as per item No 25.00 above but 10 mm tnick CM 1:6 and setting coat 5mm thick CM 1:4 mixed with WPC in external surface of wall. Note:- WPC measured and paid in revalent item of this schedule.
All as per item No 25.00 above but 5 mm thick in ceiling surfaces in CM 1:4 all as specified.
Taking up or down 15mm dia steel tubing and connection including cleaning for refixing or removal to store all as specified.
All as per tem No 28.00 above but 20 mm dia all as specified.
All as per tem No 28.00 above but 25 mm dia.
S&F 15 mm dia steel tubing medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors all as directed.
All as per tem No 31.00 above but 20 mm dia all as specified.
All as per tem No 31.00 above but 25 mm dia.
S&F in repair bib taps15 mm dia ,chromium plated cast copper alloy with fancy type knob screwed down screwed for iron pipe or for brass ferrule and fixed.
S&F in repair stop valve 15mm dia cast copper alloy, chromium plated fency type screwed down high pressure with fancy type knob screwed both end for iron pipe or for unions and fixed.
S&F 32mm Brass CP bottle traps for wash basins with inlet and outlet screwed for pipe or connection including necessary packing, union and cap and fixed all as specified.
S&F in repair 75 mm dia outlet CI nahani trap plain with S/S grating including jointing with solvent cement as directed.
S&F in repairs Vitreous china wash basin angle back size 600X480 mm white, excluding taps, waste ,chain and plug and chain porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting stand.
S&F 15 mm dia pillar tapes fency type of Chromoum Plated cast copper alloy with fancy type knob fixed to GI pipe complete.
S&F PVC waste pipe of 32 mm dia for sink all as specifiede and as directed.
S&F waste coupling of 32mm dia brass CP for glazed ware sink basins, etyc with long screwed shanks and fly nuts fanges end bedded in red lead cement and other end fixed.
S&F SS soap dish of size 100mm all as specified and as directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern) with trap front or back inlet including seat cover of any pattern complete.
S & F in repair vitreous china squatting pan 'Orissa pattern of size 580 x 440 mm white with integral foot rest( excluding flushing cistern and flush pipe) squatting pan including connecting to 'P' trap and to flushing pipe complete.
S&F in repair of low level flushing cystern 10 ltrs capacity body moulded from virgin quality high impact poly propoliyone and functional parts moulded from engneelicy grade ABS nylon and nylon glan complete incl brackets and 15mm bore 450mm long PVC connection all as directed.
S&F in repair 600mm long SS towel rail all as specified and as directed by Engineer-in-Charge.
S&F PVC water connection 600 mm long to wash basin of 15mm dia including CP nuts and washers all as specified and as directed by Engineer-in-Charge.
Taking dawn CI pipe 100mm/75mm of any description all as specified and as directed by Engineer-in-Charge.
S&F for CI waste and vent pipes in any length with or without ears, fixed to wall dia of pipe 100mm all as specified and as directed by Engineer-in-Charge.
All as per item No 50.00 above but 75mm dia pipe complete.
S&F 100mm cast iron sanitary connection-short connection pipe of length upto 300-450mm socket to fit WC out-let etc.
All as per item No 52.00 above but 75mm size connection complete.
M&L for bends of any type radius diminishing pieces or tapes ( large bore measured) of 75mm dia bore with oval access doors etc.
All as per item No 54.00 above but 100 mm size bend complete.
M&L for branch pices single (equal and unequal) ordenary or inserted (spigot or socket type) or with parallel branch of 75mm dia.
All as per item No 56.00 above but 100 mm size branch piece complete.
S&F CI cowls of 100mm all as specified and as directed..
Dismantling of water tanks of exceeding 250 ltrs and not exceeding 500 ltrs in capacity complete.
S&F rotational moulded polyethylene water storage tank of 500 ltrs capacity (cylindrical verftical with closed top) hoisted and fixed in position all as specified.
Taking down chowkats or frame n exc 1.5 Sqm each (without taking off shutter from the frame)
S&F for solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications & drawings complete
S&F factory made solid PVC moulded door shutter, 28 to 30mme thick (stiles), with 2,4 or 6 raised panel designed with 2mm thick moulded PVC sheet on front face and 2mm plain colour PVC sheet on back face as per specification and drawing complete
S&F 75mm long SS butt hinges and fixed to frame with scrwewd or welding comlete.
S&F for 200mm long aluminium anodized barrel tower bolts of extruded section and fixed.
S&F aluminium alloy anodized sliding door bolt with haps and staple (bolt type) and fixing clip of sheet cast or extruted section or cast aluminium alloy and fixed length of bolt 300mm.
S&F for 150mm long aluminium handle cast type anodized all as specified and as directed by Engineer-in-Charge.
S&F framed brackets of angles or tees with web and flanges, purlins etc, cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting,etc n exc 10 kg each brackets confirming to Fe 290 Gde-E-165
M&L for painting to new steel surface of any description over 10cm width or grith not otherwise described including preparation , priming with zinc chromate and two coats of synthetic enamel paint complete.
All as per item No 69.00 above but a coat on old steel surfaces complete.
All as per item No 69.00 above but a coat on old wooden surface except primer.
M&L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of Birla wall putty.
M&L for complete removal of existing treatment of wall surface and applyiong two coat of distemper oil emulsion over a coat of Birla wall putty in old surface of wall.
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash all as specified.
All as per item No 74.00 here in before but two coats of white wash on old ceiling surface.
M&L for preparation of new plastered surface of wall and applying two coats of cement based paint over a coat of primer.
M&L for complete removal of existing treatment of wall surface and applyiong two coats of cement based paint over acoat of primer in old surface of wall.
Supply only intergral water proofing compound.
M&L removing the tank over roof and re-fixing in the same position including cleaning all as specified and as directed.
M&L for water proofing treatment in WC, bathrooms by applying cement slurry mix with water froofing chemicalas per manufacturers specification of approved make as under (a) All corners of WC, Bath shall be rounded by poviding fillet of dia 75mm (b) M&L for 15mm rendering on floor in CM 1:3 (c) M&L for allying cement slurry @0.488kg/sqm (d) M& L for bitumen blown 90/15 applied nol, two coat to concrete surface at the rate of 1.50 Kg / Sqm per coat all as directed by Engineer-In-Charge. (e) incl demolition of lean concrete in sunken floor and refilling of lean concrete 1:5:10.
S&F 50mm dia bore pipe low density LDPE fixed to wall, ceiling or in floors etc
Cutting chases,in brick walls pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of andings steps, cills sunshades, shelves lintels etc and cutting chases for concealed water tubing and making good cutting not exc 10 cm grith complete.
Cutting holes into or through brick walls built in cement mortar superficial area not exc 150 sq cm complete.
Taking out existing unserviceable plaster, loose unsound weaken cement concrete of any description and in any position from existing surface of RCC roof sab/RCC facia/ beams/ columns/ RCC chajja, average depth 25mm (approximate 6.5 mtrs height from natural GL) with power driven pneumatic chiesel and removal of debries upto a distence 500 mtrs out side MD land including saw cutting of all edges, making square shoulders of cavaties and roughening of smooth surface, scraping out and removing corrosion and all loose scales, rust etc from the visible reinforcement and cleaning the steel reinforecement properly providing NIT zink primer of FOSROC or equivalent. Zink primer of CHEMISTIC/WEBAC on visible reinforcement surface to form a contineous film and preparing the surface to recive concrete of epoxy grouting mortar etc all as specified including providing necessary scaffolding .
M&L for applying bonding coat of modified styrene butadene emulsion (SBR bonding agent i.e nitobond SBR 45 or equivalent as approved) in proportion 1 Part (nitobond SBR 45:1 part (water) :3 part (OP cement) by volume with the brushes etc to bind new cement plaster/ polymer modified plaster/ concrete / screed concrete with oldsurface including removal of loose/ distengrated old concrete/ plaster including preparation of surface etc complete all as specified and as directed.
M&L for applying 25-35mm average thickness plaster on ceiling slab and chajja projections, facia and beams with polymer modified mortar firtified with SBR (Nitobond SBR 45 of FOSROC or equivalent of PIDILITE/ R or M International Mumbai/ 21 SHM Mumbai) in proportion 1 part (cement):3 part (sand) by weight of cement with 11 to 15 ltrs water addition, finishing surface to match with existing adjoining surface complete all as specified and directed
Dismantling of Plain or corrugated Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Excavating in trenches not exceeding1.5m wide and not exceeding 1.5m in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed..
M&L for PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including necessary formwork etc complete.
M&L for 75 mm thick PCC 1:2:4, type B-2 (using 40 mm graded crushed stone aggregate) as in coping including necessary formwork etc complete.
M&L for precast cement concrete block masonry with solid blocks of 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) exceeding 10 cm in width and setting in CM 1:6 complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1(using 20 mm graded crushed stone aggregates) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, shelves and similar articles, factory made and as approved by GE with plain fair faces including chamfering, weathering etc.complete with joint to match in CM 1:6 all as specified and directed.
M&L MS steel TMT bars 10mm dia and over cut to length ,bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams etc. complete.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of concrete, brick work surfaces including finishing the surfaces even and smooth with neeru finish all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in trenches or in floors complete.
S&F 110mm dia PVC junction single equal or unequal (single T) complete.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in trenches or in floors complete.
M&L for 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement etc.complete all as specified and directed.
S&F 110mm PVC( SWR) WC connector with lip ring.
Removing excavated materials at a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point etc. complete.
M&L for cutting into existing manholes for connecting new drain,making good to 150 mm bore pipe and rendering , cutting out existing benching for forming brackets channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) and reforming benching as required complete.
Taking dawn CI pipe 75mm of any description all as specified and as directed by Engineer-in-Charge.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in CM 1:4 complete .
M&L for PVC kitchen cabinets made with door frame of size 48x40mm (Section code RUPS-414) , shutter frame 45x300 (section code DWUF-501) and 20mm thick shutter (section code SPUF-128 or SPUF-129) including 75mm size SS butt hinges 100 mm size SS handle and magnetic catches to be fitted on every shutter all as sepcified and as directed by Engineer-in-Charge.
S&F stainless steel grating with or without hole of size 150mm fo complete.
S&F in repairs stainless steel sink 1.20 mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc, overall size 600 mm x 450 mm with bowl size 540 mm x 410 mm x 200 mm including waste coupling, waste pipe complete all as specified and directed by Engineer-in-Charge.
M & L for Cast iron pipes with spigot and socket ends centrifugally cast. Class LA,100 mm dia in any length,laid in trenches
M & L for Cast iron pipes with spigot and socket ends centrifugally cast. Class LA,80 mm dia in any length,laid in trenches
S & F in repair CI sluice valve, flanged of class PN 1.6 non raising type with stainless steel spindle supplied and installed complete of the size 100 mm dia
S & F in repair CI sluice valve, flanged of class PN 1.6 non raising type with stainless steel spindle supplied and installed complete of the size 150 mm dia
Material, laying and jointing in repair for DI Pipe K-9 ISI Marked 100 mm dia laid in trench/on ground complete all as specified and as directed
Material, laying and jointing in repair for DI Pipe K-9 ISI Marked 150 mm dia laid in trench/on ground complete all as specified and as directed
M & L for Construction of valve chamber in brick masonry built in CM (1:6) with MS cover 1:6 mm thick & locking arrangement including excavation & earth work in soft/loose soil, PCC (1:4:8) type D2 for foundation, PCC coping in cement concrete (1:2:4) type B1 plastering 15cm thick in cement mortar (1:4) applying one coat or red oxide primer & two coats of bituminous black paint on all steel surfaces including necessary earth work all as specified and shown on Drg No.CEAA/TD/57, sheet 1/1 for 1200x1200x1200mm size.
Taking up cast iron water mains (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead of 150 mm dia
Taking up cast iron water mains (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead of 100 mm dia
Taking up cast iron water mains (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead of 80 mm dia
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound techinque and necessary machine for drawing DI Pipe etc complete all as specified and as directed.
M&L for making connection by cutting existing DI main 150 mm dia under ground pipe including inserting TEE 150x150x150 mm and CI/DI collar.
M&L for making connection by cutting existing CI/DI main 100 mm dia under ground pipe including inserting TEE 100x100x100 mm and CI/DI collar.
M&L for making connection by cutting existing CI/DI main 150 mm dia under ground pipe including inserting TEE 150x150x100 mm and CI/DI collar.
M&L for Cement concrete (1:3:6) type C1 using 20mm grade stone aggregate for foundation, filling and mass concrete including necessary form work fair finishing to exposed surface complete.
Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm complte all as directed.
Supply and fix in repair CI/DI (Cast Iron/Ductile Iron) fittings like collar joints,tees, bends equal/reduced of size 150/100/80 mm bore.
Material and labour for run lead joint for cast iron / Ductile iron pipes for the following bores:-
100mm bore
80mm bore
M/L for rubber gasket joints (tyton joints ) in spigot and socketed DI pipes and fittings of size :
150mm bore
100mm bore
Supply, install ,testing and commissioning of air cooled split unit Air conditioners 1.5 TR indoor 5 star rating,of electric driven single phase, 240 volt,Copper condenser refreigerant preferably R-32 ,AC (outdoor & indoor unit)suitable for wall mounted with and including MS powder coated brackets and making/breaking hole through the wall for and passing the suction/discharge line including excess copper tubing if required beyond the length supplied with AC unit but not more than 5.00m and PVC conduit of 15mm dia not exceeding 2.5 m. long in concealed surface of wall for drainage of water, making good to disturbed surfaces with cement mortor of ratio 1:3 over and including coats of oil bound distemper over a coat of primer of matching colour complete all as directed. Note :- Rate for MS powder coated stand and extra copper pipe required shall be deemed to be include in quoted rates.
M&L for Sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on surface of wall/ceiling including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed. Note :- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit). (b) Making good to disturbed surfaces of wall etc all as directed.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps
M & L for point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS through and including 20x12 mm PVC casing capping and its accessories, cadmium screws and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable (FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing the specified and directed for for 3/5 pin 15 Amp socket on independent board.
Supplying and fixing of early steamer emission (ESE) lightening arresters fitted above the structure to be protected.The air terminal should be working on the principle of early steamer emission using no-radioactive technology, needing no external power source. The air termination should be capable of taking the lighting strock 60 micro seconds earlier as compared to passive lightening rod.ESE Comprising of following :- (a) Lightning Protection Rod(s)- 01 Nos Designed & Manufactured using S.S 304 L , Additional Protection : Side Flash Capture Head SFCH ,Overall Length is 660 mm , ICMET Certified Conforming to NFC 17 - 102 (Code of practice for lighting) ,Δt : 60μS CPRI Certified for 40kA (8/20 μS) | Main Rod Melting Point : 1450°, Weight : 6.3 Kgs approx , Radius coverage (79mtr to 107 Mtr Level I to Level IV)
(b) Lightning Protection Rod Accessories - A.L.I.C.E Digital - 1 Nos Dimensions Box : 80 x 120 x 85 mm Box U.V Resistant,Max Reading : 9999 9999 Does not require a power source,Minimum Current ( I min) : 1KA,Maximum Current ( I max) : 100 KA,Enclosure Type : IP 65 Light weight & easy to install and lightning Impulse Counter Tested for dual Polarities. Positive & Negative Can be coupled with both i.e., with Conventional LA’s as well as ESE Type LA’s Certified and tested by CPRI Bangalore. (c) Lightning Protection Rod Accessories - SLPR Accessories Box - 1 No(s) SLPR Accessories Box - List of items: 70 sqmm Lug Copper lugs 4 Nos,M8 LN Bolt with washer S.S - 2 Nos M12 Bolt S.S - 8 Nos,M12 Expansion Bolt G.I - 12 Nos LN Key for M8 Bolt - 1 Nos,Cable Tie Nylon - 12 Nos Down Conductor Clip Plastic - 24 Nos,Screw Flakes Plastic - 50 Nos
(d) Mast used for Cemented Flat surface Installation of Main pipe Outer diameter as 48mm &Thickness as 2.6 mm. Self standing base plate having pipe outer diameter as 60 mm and length 500mm with Thickness of 4.2 mm is directly welded to bottom plate of 6mm thickness ; The base plate is furnished with 12 nos of 16 mm holes for securing the base plate via M16 fasteners. Made of material is G.I ; At top of mast insulation is provided from lightning arrestor via Derlyn Mast Coupler (MC); The total height of mast is 4500mm Base plate : Self standing base plate having pipe outer diameter as 60 mm and length 500mm with Thickness of 4.2 mm is directly welded to bottom plate of 6mm thickness ; The base plate is furnished with 12 nos of 16 mm holes for securing the base plate via M16 fasteners. Made of material is G.I (e) Mast Coupler - 1 No
M & L for earthing of equipments with copper plate earth electrode 60cmx60cmx3.15 mm thick buried directly in ground (earth pit not less than 3.00 mtr below ground level with top edge of plate not less than 2.25m. below ground level) brazed with copper strip 20x3 mm size 7.0 mtr long and connected to copper strip of any size by means of copper bolts, nuts, check nuts and washers complete all as specified and directed. Note:- The rated quoted is deemed to the inclusive of the followings:- (a) The excavation and earth work (filling in, ramming in layers, watering etc as directed) in any type of soil for earth pit (pit size 1.20x 1.20x3.0mtr). (b) Perforated GI tubing (ISI marked) light grade 50mm bore 7.0 mtr long for strip protection and watering. (c) Common salt charcoal dust in alternative layers of 15cm, up to 60cm above the top of copper plate all as directed (Salt - 300Kg, Charcoal dust - 500 Kg).
(d) Earth chamber of internal size 600mmx600mmx600mm, built in PCC (1:3:6) type C2 bed 15cm thick at bottom, brick work in CM 1:6 upto 45cm over PCC bed and PCC (1:3:6) type C1 coping 15cm above, embedded with MS angle 50mmx50mmx3mm frame work duly painted with anti corrosive bituminous paint, with and including RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with XPM (weight not less than 4Kg per Sqm) having lifting arrangement duly painted in green and making earth pit as directed. (e) On testing, after completion, if the earth resistance < 2 Ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained. (f) GI tubing, bib tap etc for provisioning of continuous water supply at earthing pit will be measured and paid seperately under respective schedule of the contract.
S & F 70 Sqmm flexible copper cable single core for connecting lighting rod to earthing all as directed.
Taking up and down XLPE cable of size any size and deposit to MES store or as schedule of credit all as specified and as directed.
Supply,laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core
Supply,laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core
Supply,laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 Core.
Supply, install, tesing and commissioning weather and vermin proof LT feeder pillar box (Panel board) factory fabricated in outdoor type totally enclosed made out of 3.15mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 50 X 50 X 6mm suitable for operation of 3 phase, 4 wire, 440 volts, 50 Hz system, with hinged panel door (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable of sufficient Nos. of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc. inside the enclosure, the required Nos. of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor (.....Contd)
PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium and LT Panel should be CPRI and fabricated from CPRI approved fabricator complete all as specified and as directed and consisitng of following:- (a) Bus bars of copper strips of 200 Amp current capacity, length as actually required at site of 3 phase and half size for neutral, mounted on epoxy/ FRP bus insulator - 01 Set. (b) MCCB 100 Amps TPN 16 KA, 415 V - 01 No. for incoming. (c) MCCB 63 Amps TPN 16 KA, 415V - 03 No. outgoing. (d) Internal wiring with copper conductor including necessary lugs and thimbles 1 Job.
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound techinque and necessary machine including GI pipe of 50 mm dia, light grade for drawing under ground cable etc complete all as specified and as directed.
Supply and laying clean dry sand for cable cushioning including gently punning down all as directed.
M & L for burnt brick old size sub class 'B'laid in trenches abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complte all as specified and as directed.
Supply and fix/ laying GI pipe light grade of size 50mm dia for cable protection with all fittings on wall/ pole or laid in trenches/ ducts/ floors/ ceilings etc complete all as specified and as directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store or as schedule of credit all as specified and as directed.
Supply,installation, testing and commissioning of old MH/HPSV/CFL fittings with 70 Watt LED street light Fixture made of Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant and lumen efficacy of > 100 Lm/W with integral electronic driver,IP 66 Protection,Rated CCT 6000 K,240 V AC suitable for pole mounting of bracket 40 mm dia. Cable gland shall be used for maintaining ingress protection.
S&F in replacement LED security light luminaire 1x22W having IP-65 protection,di-cast, aluminium alloy for housing having heat dissipation fins,sturdiness & corrision resistant,roadway luminairepowered by an integral driver , high power LED as light source, minimum lemen efficacy of 140 lm/w all accessories (including brackets) and connecting up to ceiling rose and fittings with 1.5 sqmm, 3 core PVC insulated copper conductor cable and all as specified and directed by Engineer in Charge.
Supply and fix PVC wire in two runs, single core, PVC insulated cable copper conductor, 1.5 sqmm and one run of single core PVC insulated cable copper conductor 1.5 sqmm from looping box to street light fitting terminal complete all as specified and as directed.
Supply and fix cap type, single arm bracket 1.5 mtr long of size 40mm dia GI pipe light grade with nuts and bolts complete all as specified and as directed.
M&L for flame proof point wiring complete using colour code with two run of 1.5 Sqmm single core multi-stranded copper conductor ZHLS PVC insulated and unsheathed multistrandard copper conductor cable 1100 V grade conforming to IS-694 drawn through and including ERW steel conduit 20 mm dia (external flame proof) heavy grade (IS Marked) including necessary all accessories/fixtures , on wall surfaces , ceiling including sunken type pressed steel terminal boxes with flame retardant sheet of approved shade 3 mm thick including providing continuous earth wire with one single run of 1.5 sq mm single core mult-stranded copper conductor ZHLS, PVC insulated and unsheathed cable 1100 volts grade conforming to IS 694 for one light point controlled by one way flame proof switch etc , complete all as directed by Engineer-In-Charge. Note : The cost of cutting chases in wall /floor/ceiling wherever required and making good the surface as exists shall be deemed to be included in respective items of schedule.
S&F Flame proof and weather proof single pole rotary/cam switch on-off with direct entry single pole 16A on-off in AL LM-6, 230V complete. Make:- Sudhir Switch gear Pvt Ltd Cat No. SS/OA/1010-2A / Flexpro Cat Part No. (R) MFRS/104/1-New Model/ Baliga/Alsthom/ GEC & certified by CMRI Dhanbad all as directed by Engineer-in-Charge.
S&F Exhaust fan, Flame proof, Single Phase, 230/240 Volts, 50 Hz of Size 457 mm (18") size, 0.33 HP motor, 1440 RPM, 4000 CFM, heavy duty with louvers all as directed by Engineer-in-Charge. Make:- Baliga / Shudhir / GEC / Alsthom
M & L for making opening/hole suitable for fixing exhaust fan 457 mm sweep including plastering finising and making good the existing surface all as directed by Engr-in-charge.
Supply and fix exhaust of 300mm sweep Metal Body, 230/ 240V, 900RPM, AC, single phase, complete with louvers and shutters and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceiling rose to connector fan and grouting 04 Nos full threaded bolts and nuts etc including making opening/ hole suitable for fixing exhaust fan including plastering, finishing and making good the existing surface complete all as specified and as directed.
Material and labour for point wiring complete with 1.5 sqmm single core multistandard copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through and including non metallic rigid PVC heavy duty concealed conduit (min 20mm dia external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part-I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5sqmm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electroplated of suitable size with bakelite white/ colored top sheet cover 3.0mm thick and connected to common earth dolly complete all as specified and directed for
(a) One fan point controlled by one, one way switch.
(b) One 5 Amp switch socket outlet combination on independent board
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, 240 volt grade, ISI marked complete all as specified and as directed.
Supply and fix ceiling rose, surface bakelite, 65x50mm size, three terminals, ISI marked complete all as specified and directed.
S&F Pedestal fan 400 mm sweep maximum power consumption 61 watts for AC 230 volts 50 Hz with strandard accessories etc complete
Supply and fix switch socket combination, multipurpose, 2 in 1, 5 Pin, 5 Amps, AC, flush type, ISI marked complete all as specified and as directed.
M/s SK Traders
Shree Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .