Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹6.2 L
EMD Value
₹12,364
Closing Date
26 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Construction of 10 Roomed Additional class room building at BHSS Pattan B.W.O Electric work.
2025_PWDJK_298248_1
NIT No.223/2025-26 Dt/15/12/2025
Open Tender
Electrical Works
Percentage
pattan
Please refer Tender documents.
4 documents required · 4 mandatory
₹300
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹12,364
15 Dec 2025
15 Dec 2025
27 Dec 2025
15 Dec 2025
26 Dec 2025
15 Dec 2025
Wiring for light point / exhaust /ceiling fan point with (P+N) 2X1.5 sq.mm FRLS-H ( Polycab/Havells/eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/ polycab/ Ravindra/ equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand mylinc/SSK NV/ABB Tvisha make as approved by site engineer), modular plate, cover in front and suitable GI box (Excld. G.I Box laid earlier )etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. including cost of Conduits ( Separate wiring for inverter points)
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate (Anchor roma urban/legrand mylinc/SSK NV/ABB Tvisha / eq. make to be approved by EIC
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/ eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified (Anchor roma urban/legrand Mylinc/SSK NV/ABB Tvisha/ eq. make & shall be approved before execution of work.
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/ eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified (Anchor roma urban/legrand Mylinc/SSK NV/ABB Tvisha/ eq. make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Polycab/Havells/ eq. make to be approved by EIC)
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting and Inverter Sub main in one run from Main Panel to Distribution board(Polycab/Havells / eq. make to be approved by EIC)
2 X 4 SQ.MM + 1 X 4. SQ.MM [Phase +N+E) For Inverter Sub main in one run from Main Panel to Distribution board (Polycab/Havells / eq. make to be approved by EIC)
SINGLE POLE (6-32Amp) MCB Legrand /Havells or L&T /Schneider/ABB/ eq. make to be approved by EIC
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve Residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
32 Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make to be approved by EIC ( For inverter circuit)
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make to be approved by EIC
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/ eq. make to be approved by EIC
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havells or Jaquar or Eq make
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ eq. make to be approved by EIC
S/L , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
d) 50 sq.mm 3.5 core ( armoured)
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips/ eq. Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. Havells/Philips/Jaquar/Eq make
Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall nounted compartmentalized , Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming 120 Amp TPN MCCB 35 kA with thermo magnetic adjustable based of Legrand / Siemens/ ABB /Schinder /L&T make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set Volt meter =1 no, Ammeter = 1 no ,phase indicators =1set 100 Amp 4 Pole change-over to switch from normal supply to DG supply Legrand/Havells/L&T/Schineider/ABB make Outgoing: 1) 40 Amp DP = 2 No. for Lighting Circuits 2) 63 Amp DP = 2 No. for Heating Circuits 3) 32 Amp DP = 2 No. for inverter Circuits of Legrand/Havells/L&T/Schineider/ABB / eq. make to be approved by EIC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_966719.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .