Loading…
Loading…
Tender ID
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Feb 2026, 6:00 pmClosed
LT COL CHETAN KOTKAR, GE (SOUTH) AMBALA
GE (SOUTH) AMBALA CANTT
CA NO GE(SOUTH) AMB 78/2025 2026 REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION SYSTEM AND DAY TO DAY MAINT/ASSOCIATED WORKS INCLUDING CEILING FANS GEYSERS EXHAUST FANS AT VARIOUS MD ACCN OF B 2 SECTOR NEAR SARDAR PATEL ROAD UNDER GE(S) AMBALA
2026_MES_748027_1
GE(SOUTH)/AMB-78/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹70,000
Yes
10 Jan 2026
10 Jan 2026
11 Feb 2026
10 Jan 2026
9 Feb 2026
26 Jan 2026
10 Jan 2026 - 24 Jan 2026
Material and labour for attending day to day complaints of E&M nature by means of checking unserviceable electrical fitting and fixture and emergent fault rectification in elctrical circuit including no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates. (d) Penalties/recoveries shall be leviable due to absence of Electrician @ 800/- per day and Helper @ 500/- during the working day.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, complete all as specified and as directed by Engineer-in-Charge.
Supply only switch, single pole two way 6 Amps, 230 volts AC circuit complete all as specified and as directed by Engineer-in-Charge.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, complete all as specified and as directed by Engineer-in-Charge.
Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed by Engineer-in-Charge.
Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, , complete all as specified and as directed by Engineer-in-Charge.
Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply only fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed by Engineer-in-Charge.
Supply only door bell electric ,ding dong /musical type, single phase 230 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply only switch modular 6 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only switch modular 16 amps, one way single module with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only bell push modular with and including necessary frame and cover i.e. inner and outer plate as per existing make / site requirement and type complete all as specified and as directed by Engineer-in-Charge.
Supply only Fan condenser 2.5 mfd complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC insulated, unsheathed cable 4.00 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed by Engineer-in-Charge.
Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed by Engineer-in-Charge.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply only MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC Plug Top 3 pin suitable for 5/6 Amp socket complete all as specified and directed by Engr-in-Charge.
Supply only PVC Plug Top 3 pin suitable for 15 Amp socket complete all as specified and directed by Engr-in-Charge.
Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and as directed by Engineer-in-Charge.
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (Fire Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 29.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 29.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 29.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through in existing non metallic/mettalic medium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 33.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 33.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 33.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular socket outlet 6/20 amps,3 pin, 2 module, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular blanking plate 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed by Engineer-in-Charge.
Supply and fixing door bell electric ,ding dong /musical type, single phase 230 volts, complete all as specified.
Supply and fixing in repair sheet metal enclosure SP with two pin and earth plug and socket including metal clad top with one single pole, MCB 20 Amps, 'B' curve, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Decorative ultra slim linear surface mounted Aluminium Extruded LED lighting fixture (4 feet length), 20Watt LED with input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K and system Lumens not less than 2000 lumens with High efficiency long life LED with lumen efficacy not less than 100 lm/W, Degree of protection should be IP 20 complete with Integral electronic driver (SMPS Based constant current out put) with lower THD, Output short cicuit protection/Open circuit protection, surge voltage protection up to 2KV and PF should be not less than 0.9 complete including taking down unserviceable light fittings all as specified and directed by Engr-in-charge.
Supply and fixing Decorative ultra slim linear surface mounted Aluminium Extruded LED lighting fixture (2 feet length), 10Watt LED with input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K and system Lumens not less than 1000 lumens with High efficiency long life LED with lumen efficacy not less than 100 lm/W, Degree of protection should be IP 20 complete with Integral electronic driver (SMPS Based constant current out put) with lower THD, Output short cicuit protection/Open circuit protection, surge voltage protection up to 2KV and PF should be not less than 0.9 complete including taking down unserviceable light fittings all as specified and directed by Engr-in-charge.
Supply and fixing Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, pessure Die cast aluminium housing and high quality polycarbonate UV protected diffuser with input voltage AC 220V-240V, 50 Hz, with colour temperature 6500K and system Lumens not less than 1000 lumens with High efficiency long life LED with lumen efficacy not less than 100 lm/W, Degree of protection should be IP 65 complete with Integral electronic LED driver with APFC and lower THD, Output short cicuit protection/Open circuit protection and surge voltage protection up to 4KV (Inbuilt) and PF should be not less than 0.90 complete including taking down unserviceable light fittings all as specified and directed by Engr-in-charge..
Supply and fix bracket for security light made up of 25mm dia suitable for security light, 0.9 metre long MS pipe, light grade, bent of 135 degree angle to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete including taking down unserviceable bracket all as specified and directed.
Supply and fixing New generation energy saving and environmental friendly long life LED street light of 30 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with input voltage AC 220V-240V, 50 Hz, with colour tempetrature 6500K and system Lumens not less than 2500 lumens with High efficiency long life LED withSMD LED on MCPCB lumen efficacy not less than 100 lm/W, Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open /Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection up to 4KV (Inbuilt) and PF should be not less than 0.90 including making good disturbed surface complete including taking down unserviceable light fittings all as specified and directed by Engr-in-charge.
Supply and fixing New generation energy saving and environmental friendly long life LED street light of 45 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with input voltage AC 220V-240V, 50 Hz, with colour tempetrature 6500K and system Lumens not less than 2500 lumens with High efficiency long life LED withSMD LED on MCPCB lumen efficacy not less than 100 lm/W, Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open /Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection up to 4KV (Inbuilt) and PF should be not less than 0.90 including making good disturbed surface complete including taking down unserviceable light fittings all as specified and directed by Engr-in-charge.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. NOTE: - 3 run of 2.50 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. NOTE:-3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Supply and fixing in repair SPN distibution board 12 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets including taking down old unserviceable DB with MCBs complete all as specified and directed.
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets including taking down old unserviceable DB with MCBs complete all as specified and directed.
Supply and fixing in repair SPN distibution board 4 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets including taking down old unserviceable DB with MCBs complete all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and directed by Engineer-in-Charge.
Material and labour for taking down existing lighting fiting any type/size/Make/capacity and re-fixing the same after minor repair/cleaning including replacement connection wire with suitable size coper wire twin core 0.75 sqmm for connection from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs LED Lamps 9 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs LED Lamps 12 Watt B22/E27 suitable for batten holder including taking down existing lamp of any description complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting type LED round type Decorative ,wall mouting , bowl type/metal base with glass with 7 Watt LED Warm white B22 Lamp including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting & making hole in wall of suitable size in round/ square shape for fixing Exhaust fan of size upto 300mm sweep and making good with plaster / matching with existing surface complete all as specified and directed by Engineer-in-Charge.
Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair complete all as specified and directed.
Supply and fixing in repair fan condencer 2.5 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair hanging assymbly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed by Engineer-in-Charge.
Material and labour for painting of ceiling fan using synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour complete all as specified and directed by Engineer-in-Charge.
Material and labour for hanging only ceiling fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed.
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed by Engineer-in-Charge. NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Material and labour for taking down Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismenteling of blades and deposited to store for repair complete all as specified and directed by Engineer-in-Charge.
Material and labour for rewinding of Exhaust fan/wall fan of any size with super enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing, of size 225 to 300 mm sweep complete all as specified and directed by Engineer-in-Charge. NOTE for item No 2,3 and 8 to 12 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Material and labour for fixing only exhaust fan any type/sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of plastic body exhaust fan, AC singal phase, 240 volts of size 250 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of wall mounting fan,AC single phase,240 Volts of size 400 mm sweep,1400 rpm ,copper wound complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning, soldering / welding works as required & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed by Engineer-in-Charge. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Taking down old unserviceable geyser of cap 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse including all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning, soldering / welding works as required & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed by Engineer-in-Charge. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Supply only heating element of capacity 2 KW of geysers of any make complete all as specified and directed by Engineer-in-Charge.
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed by Engineer-in-Charge.
Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar 90 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete all as specified and directed by Engineer-in-Charge.
Supply only Non-return valve 15mm / 20mm dia of brass as per requirement complete all as specified and directed by Engineer-in-Charge.
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed by Engineer-in-Charge.
Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Supply only geyser storage inner tank made out of stainless steel sheet suitable for 50 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
Supply only nut and long bolt set fastener made of steel, length not less than 10 cm as per site requirement for fixing of geysers complete all as specified and directed by Engineer-in-Charge.
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core complete all as specified and directed by Engineer-in-Charge. (Cable shall be in suitable length as per site requirement).
Supply only heating element of capacity 1.5 KW of geysers of any make complete all as specified and directed by Engineer-in-Charge.
Supply only metal clad plug top 3 pin 20 Amp 230 Volts round shape suitable for AC box complete all as specified and directed by Engineer-in-Charge.
Supply only Rigid non metalic PVC casing capping of 25/16 mm inclusive of elbow tees, etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
Supply only Rigid non metalic PVC casing capping of 20/12 mm inclusive of elbow tees, etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
NOTE:- Amount of credit of Rs. 80,128.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_837692.xls
BOQ • 0.38 MB
Tenderdocuments78.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .