Executive Engineer
Executive Engineer, Mechanical Division, PWD
Providing installation and commissioning of Split type Air Conditioning machine at Dhalai District Hospital Kulai Dhalai Tripura during the year 2021_22
2021_CEPWD_18612_1
07 _EE_DNIeT_MECH_DVN_AGT_21_22
Open Tender
Electrical Works
Item Rate
30 days
District Hospital Kulai Dhalai Tripura
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹14,474
Yes
5 Jul 2021
3 May 2021
17 May 2021
3 May 2021
17 May 2021
3 May 2021
Amount
Providing, of Split type Hi-wall AC machine with inverter compressor technology operating on non- CFC refrigerant(R-410/R-32/ equivalent refrigerant) suitable for wall mounting conforming to IS: 1391(Part-III) specification(evaporator & condenser must have copper pipe) suitable for operation on230 V +- 10%, not less than 3(Three) star rating 50Hz, 3pahse AC power supply capable of performing a) cooling b) Dehumidifying c) Air Circulating d) filtering as per direction of the Engineer-in-Charge
1.50TR(4500Kcal/hr.)
2.0TR (6000 Kcal /hr.)
Providing, of Cassette type Split 2.00 TR (6000 Kcal/hr.)AC machine with inverter compressor technology operating on non- CFC refrigerant(R-410/R-32/ equivalent refrigerant) suitable for wall mounting conforming to IS: 1391(Part-III) specification(evaporator & condenser must have copper pipe) suitable for operation on230 V +- 10%, not less than 3(Three) star rating 50Hz, 3pahse AC power supply capable of performing a) cooling b) Dehumidifying c) Air Circulating d) filtering as per direction of the Engineer-in-Charge
Standard Installation, testing and commissioning including necessary cement plastering of holes of 1.5 TR/ 2.0TR capacity High wall split Air Conditioning Machine.
Standard Installation, testing and commissioning of 2.0TR capacity Cassette split Air Conditioning Machine.
Fabrication of M.S platform for placement of condensing unit by using MS angle of appropriate size base plate, nut bolts/ universal bracket (GSS) for ODU of split ACs including all accessories for onsite installation i/e painting, fittting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply and installation of additional length of copper pipe of suitable diameter (suction and discharge line) as per manufacturer requirement with insulation and necessary wiring between indoor and outdoor units.
Providing hard PVC Pipe of best quality of appropriate size as per requirement including necessary clamping and fitting for draining of condensate water from inddor unit as per direction of the Engineer-in-charge.
Providing hard PVC Pipe of best quality of appropriate size as per requirement with suitable insulation including necessary clamping and fitting for draining of condensate water from inddor unit as per direction of the Engineer-in-charge.
Providing and connecting Electric Control cables between MCB to inddor/outdoor. A)3Cx2.5 Sq. Mm copper cable
Providing and fitting fixing of 15amps power Top as per direction of the Engineer-In-Charge.
STANDARD ELECTRONICS
SATISFACTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_18845.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .