Executive Engineer, Water Works Project, Vadodara Municipal Corporation
DEMOLITION OF EXISTING GSR, PUMP HOUSE AND CONSTRUCTION OF NEW GSR, PUMP HOUSE, WITH NECESSARY COMPONENTS AT CHANNI JAKATNAKA WATER HEAD WORK, VADODARA.
310273
125/2026-27
Open
Civil Works - Water Works
Vadodara
3 documents required · 3 mandatory
₹20,000
MUNICIPAL COMMISSIONER ,VADODARA MUNICIPAL CORPORATION
₹10.9 L
2 Jun 2026
2 Jun 2026
2 Jun 2026
23 Jun 2026
2 Jun 2026
BILL OF QUANTITIES
1. The bill of Quantities shall be read in conjunction with the Instructions to Bidder,
Conditions of Contract, Technical Specifications and Drawings.
2. The quantities given in the Bill of Quantities are estimated and provisional, and are
given to provide a common basis for bidding. The basis of payment will be the actual
quantities of work ordered and carried out, as measured by the Contractor and
verified by the Engineer and valued at the rates and prices tendered in the priced
Bill of Quantities, where applicable, and otherwise at such rates and prices as the
Engineer may fix within the terms of the Contract.
3. The rates and prices tendered in the priced Bill of Quantities shall, except in so far
as it is otherwise provided under the Contract, include all constructional plant,
layout, supervision, materials, erection, maintenance, insurance, profit, taxes and
duties, together with all general risks, liabilities and obligations set out or implied in
4. The rates and prices shall be quoted entirely in Indian Currency.
5. A rate or prices shall be entered against each item in the Bill Quantities, whether
quantities are stated or not. The cost of Items against which Contractor has failed to
enter a rate or price shall be deemed to be covered by other rates and prices
entered in the Bill of Quantities (in case of Item rate contract).
6. The whole cost of complying with the provisions of the Contract shall be included in
the items provided in the priced Bill of Quantities, and where no Items are provided
the cost shall be deemed to be distributed among the rates and prices entered for
the related items of Work.
7. General direction and descriptions of work and materials are not necessarily
repeated or summarized in the Bill of Quantities. References to the relevant sections
of the contract documentation shall be made before entering rates or prices
against each item in the Bill of Quantities.
8. The method of completed work of payment shall be in accordance with the
specification for Road and Bridge works. For building works specifications for
building are to be followed.
9. Errors will be corrected by the Employer for any arithmetic errors pursuant to Clause
29 of the Instructions to Bidder.
10. Rock is defined as all materials which, in the opinion of the Engineer, required
blasting, or the use of metal wedges and sledgehammers, or the use of compressed
air drilling for its removal, and which cannot be extracted by ripping with a tractor of
at least 150 kw with a single rear mounted heavy duty ripper.
1 The Contractor shall exhibit a board with detailed specification and details
of work as directed by the Engineer-In-Charge for which no extra payment
2 The labour cess will be deducted from the bill amount excluding GST as per
prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of
BILL OF QUANTITIES
Item No Item Description Quantity Rate Unit Amount
DEMOLITION WORK
1 Dismantling of Existing U/G Sump at Channi 1.00 -1808290.00 No. -1808290.00
Jakatnaka Campus by using crane and handing over
pipes, valves, bends, etc. safely to the Department.
However taking steel reinforcement by the
dismantling agency including removing dismantled
2 Dismantling of Existing Pump House at Chaani 1.00 -645299.00 No. -645299.00
Jakatnaka Campus However taking steel
reinforcement by the dismantling agency including
removing dismantled materials from site and
disposing them at VMC Limit as dirrected by EIC.
Recovery items from dismantling of the existing U/G sump (Item Nos. 1 and 2) shall be payable by the Agency to the
Department at the estimated rate of ₹24,53,589.00 only. This item shall remain fixed and shall not be subject to any
percentage above or below quoted by the bidder.
1 Designing structurally (and aesthetically) & 10000000.00 3.44 Liters
Preparing structural design of RCC Under Ground /
Partially underground / above high ground level
Reservoir of required capacity with Construction of
Pump house having 200.0 SQM and Panel Room
200.0 SQM with Minimum 6.0 M Height from Top
Slab of Sump to Bottom Slab of Pump House or ( As
Per Pump manufacture requirement) above Sump
NAME OF WORK : PROVIDING AND SUPPLYING HS FEEDER LINE AND REQUIRED DISTRIBUTION LINE FOR CHHANI
Sr. Item Description Quantity Rate Unit Amount
1 Excavation for pipe line trenches for water supply ,sewerage line 800.00 102.35 Cum
,manhole etc all with shorting and struting if requried as per
requried gradient adn line includin all safety provisions using site
rails and staking excavated stuff including upto requried lead
cleaning the site etc complete fro all lift and starta as specified a)
0.0 mt to 1.50 mt. depth.
2 Manufacture, Supply & Delivery of Electric Resistance Welded (Up 200.00 21000.00 Rmt
to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe
having beveled ends plate or coil conforming to IS-3589-2001 or
its latest revision/ ammendment for following thickness outside
diameter at GWSSB store or site anywhere in Gujarat State
including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading conveyance to
Departmental stores, stacking etc. all complete.
914 mm dia MS Pipe with 8 mm thick with 25 mm Cement motar
lining & Outside 25mm thick Guniting
3 Lowering, Laying & Jointing and welding in position, to correct line 200.00 948.75 Rmt
and level M.S pipe & Specials with outer gunnintig and inside
lining/Epoxy painting on padestal or chairs up on prepared
formation or prepared bedding in trenches the rates incl bedding in
trenches the rates incl conveyance from store to site of work
loading,unloading,joint platering hystrotesting etc.
914 mm dia MS Pipe with 8 mm thick with 25 mm Cement motar
lining & Outside 25mm thick Guniting
4 MS Specials plain ended/flange ended Manufacture, supply and 1200.00 96.00 Kg
delivery of 80 mm to 300 mm dia Mild steel plain ended/flange
ended specials complete like tee, bend, skew tee etc. as per IS. The
delivery of specials is to be made to VMC store or sites including
all taxes, loading, carting, unloading, stacking, insurance, octroi,
inspection charges etc. complete as per instruction of engineer in
M.S Specials above 300 MM Plain & Socket ends
M.S Specials above 300 MM Flanged Ends 1200.00 98.00 Kg
5 Refilling the pipeline trenches incl. remming, watering, 1300.00 25.30 Cum
consolidating desposal of surplus stuff as directed within a radius
6 Supply, installation, testing and commissioning of Manually Gear 2.00 58089.05 Nos.
operated Horizontal shaft DI DF Butterfly Valve, conforming to IS
13095 / BS 5155, PN 1.6 with SS 304 renewable seat rings,
indicator, gear box with bolts, nuts & washers, gaskets, etc. as per
specifications and complete in all respect.Size: 600 mm Dia
Sr. Item Description Quantity Rate Unit Amount
7 Providing and casting in situ C.C. in grade M-15 (approx. corresp. to 30.00 5641.90 Cum
prop. 1:2:4) (proportions as per mix design or as per Table 9 of
IS456 2000 in masses by weigh batching ) using granite, quartzite
trap metal of size 6 mm to 20 mm for RCC work, including
scaffolding centering, form work, needle vibrated consolidation,
curing comp. up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure for other than
water retaining. For PCC
8 Providing and casting in situ C.C. in grade M-25 (approx. corresp. to 28.00 9288.55 Cum
prop. 1:2:4) (proportions as per mix design or as per Table 9 of
IS456 2000 in masses by weigh batching ) using granite, quartzite
trap metal of size 6 mm to 20 mm for RCC work, including
scaffolding centering, form work, needle vibrated consolidation,
curing comp. up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure for other than
water retaining.
Flat Bottom Slab/ Floor Slab/ Slab with Shuttering
Beams/ring beams/girders 3.00 9599.05 Cum
9 Steel /Reinforcement bars: Supplying cutting, bending, binding and 3.00 89129.60 MT
placing in position steel as per plan and design and as per ISS
2502 including cost of steel and binding wire for
reservoirs/structures only including lift up to 6 meter height or
depth below G.L. for all diameters Do-deformed (TMT) bars
confirming to relevant IS Fe -500 grade for all diameters. Do-
deformed (TMT) bars confirming to relevant IS Fe -500 grade for
10 Brickwork using common burnt clay building brick having crushing 50.00 4080.74 Cum
strength not less than 35 kg/sq.cm in foundation and plinth in
cement mortar 1:6
11 Provinding 10 mm thick inside cement plaster in Cement mortar 90.00 192.60 Smt
(1:3) to stone or brick masonary including racking out the joints and
niru or cement finishing etc complete.
12 Cement plaster 20 mm thick in C.M. 1:2 using water proofing 84.60 232.30 SQM
compound of approved quality including finishing etc. complete.
13 Supplying and fixing the MS cover for valve chamber with required 6600.00 85.99 Kg
channel, girder, plate, angles with hole above to operate valve
including required chain to open and paint two coats of redoxide
and two coats of anti corrosion paint. etc complete as per the
instruction of Engineer in charge.
14 P.P Steps: for Riser of Valve Chamber Above 300 mm 10.00 100.00 Nos
15 Demolition including stacking of serviceble materials and disposal 10.00 1073.56 Cum
of unserviceble materials with all lead & lift [i] R.C.C. work
16 Demolition including stacking of serviceble materials and disposal 10.00 558.57 Cum
of unserviceble materials with all lead & lift [i] Brick work.
Sr. Item Description Quantity Rate Unit Amount
17 Gas Cutting of MS Pipe I Plates : Gas cutting(Either square cut or V 50.00 64.40 Rmt.
cut) pipes, plates etc. including all costs for the followng thickness.
18 Welding in all positions with required number runs, for M.S. Pipes 50.00 838.35 Rmt.
internally and/or externally including gauging wherever necessary,
fixing appurtenances and other accessories in connection with pipe
laying work as per specification.
19 Dewatering by pumping set of required capacity including 1600.00 21.07 Hp/Hr.
temporary platform carting pumping at site and fixing the same in
position including all accessories, and fuel and labour etc.
20 Manufacture, Supply & Delivery of Ductile Iron Flange socket 1000.00 158.00 Kg
spigot bends, tees, reducers or any other specials as per BS-EN-
545/1995 Class-A series K12 suitable for use with D.I.Pipes
manufactured as per IS:8329/1994 delivery of specials is to be
made to GWSSB store or site of works any where in Gujarat
including all taxes, leading, unloading, carting, stacking, insurance,
inspection charges, octroi etc. complete.
B. Flanged ended
21 Cutting of CI/DI pipes : Labour charges for cutting pipes with the 500.00 1.27 CM
help of requisite tools and as directed. 1) Pipe thickness upto 11 mm
2) Pipe thickness upto 11 mm to 20 mm 500.00 1.61 CM
22 Removing tiled or stone/paver block floor laid in mortar including 50.00 30.00 Sqm
stacking of serviceble material and disposal of unserviceble
material with all lead and lift.
23 Laying and fixing of 50mm thick interlocking paver block as per 50.00 140.55 Sqm
design given by Engineer Incharge with 50mm thick sand bed
layer, watering, compacting paving with compacter by mechanical
compacter etc. complete as per specification
24 Uninstallation of existing pumping machinery from existing pump 1.00 500000.00 Nos
house including all pumps,panel,cables,valves,
NRV,specials,Existing Insrumentation equipments etc. with all lead
and lift to specified department store or as specified by EIC.
25 Job Connection For Proposed Line to Existing Line Connecation 2.00 35100.00 Nos.
with Necessary all Tools Tackels labours and requriements and
instruction of EIC. 914 mm dia
PLOT DEVELOPMENT
SR. NO. ITEM DESCRIPTION Qty Rate Unit AMOUNT
1 Construction of internal RCC road: Trimix plain cement concrete pavement with VDS 300.00 2540.00 Sqm
with M25 Grade thickness as per design, over a prepared sub base of GSB & WMM as
per drawing , with reinforcement and design Mix as tender specification and directed by
engineer-in-charge.
2 Construction of toilet block, water supply to toilet block for drainage arrangement as 3.00 23850.00 Sqm
per planning and design including neccessary fittings Carpet Area of toilet block is min.
3.00 sq.mt. and as per detail tender specification
3 Design & Construction of Office room as Per site condition including inside outside 35.00 18350.00 Sqm
plaster, painting, Polished Kota Stone Flooring with side skirting, with wooden doors,
windows with aluminium with Safety MS grills, internal concealed electrification ,Office
Furniture (10 Chairs and 2 Nos Revolving Chairs) with 1.5 MT AC etc complete as per
detail tender specification.
4 Providing,Supplying Lowering and Laying of 300 MM RCC Np3 Class Pipe with Catchpit 100.00 3180.00 Rmt.
Chambers as per Drawing and make necessary arrganmant of disposal of Storm Water
from inside the plot as per site condition and Specification
5 75 mm thick interlocking rubber moulded gram paver block (hollow paver block) (M-25 600.00 1,017.00 Sqm
grade) in the selected shape from here, 25.0 mm in line level. Sand cushion and placed
in the design, compacted with a mechanical compactor of 2 to 3 tons capacity, placing
work as per the required joints. Manufacturer Must Have ISI (For 10.0 sq.m. area)
6 Providing and laying and fixing of 80mm thk (M45 Grade) interlocking coloured 1750.00 697.10 Sqm
RUBBER MOULD paver block as per selected design and colour given by Engineer in
charge with 75 mm thk sand bed layer, watering, compacting, paving with compacting
by mechanical compacter etc.
7 Construction of compound wall as per attched drawing with 2 no. steel gate with oil 50.00 12900.00 Rmt.
paint painting required as per site condition.
Sr.No Item Description Qty. Rate Unit Amount in Rs.
A MECHANICAL WORKS
1.0 Chlorination System
Providing, Supplying & installing Vacuum Control Direct wall mounted gas
chlorinator including necessary fittings, installation and commissioning of plant incl.
Clamp, copper pipe, ferule filter & control valve with injector.
5 Kg. Capacity [Cabinet Type]
Each Plant shall include the following:
1) 1 no. submersible monoblock pump motor set with continuous cable from pump to
starter panel without any joint with proper conduit piping and clamping.
2) 1 no. of diffuser.
3) 1 no. of Ejector
4) 1 no. of Cholrinator
5) 1 no. of Vaccum Regulators
6) 1 No. of strainer
7) 5 Nos. Isolation Ball Valves 2.00 210642.00 NOS
8) 1 Non return Valve
9) 2 Nos. yoke clamp (1 Nos for each cylinder)
10)1 No of Pressure Gauge with require piping and isolation valve
11) 1 no. of Chlorine gauge at C12 manifold
12) 1 Lot of puiping, fitting, valves & instruments
13) 1 Nos. starter panel with TPN MCB with necessary cabling & electrical
connections etc. and other necessary items as per IS & tender Specification and
14) Vaccum guage
15) MS support of 50 mm x 50 mm x 4mm thk.
16) 3C copper armour power cable from PMCC panel to chlorine room of required
size with proper piping & clamping as required.
17) any other as required to complete with all work in all respects.
1.1 Chlorine Safety equipments & vacuum control type gaseous chlorination plant.
1) 1 set kit for 900 Kg. Cap. Toner
2) 1 set Air breathing apparatus for 45 min as per IS.
3) Chloroscope 0.5 ppm including testing materials.
4) 1 set Emergency tool kit
5) 1 no. Ammonia torch 1.00 89014.00 Set
6) 1 – lot inter connecting piping of identical pipe size of C12 booster oumps delivery
line with isolation valve.
7) 1 No. common 3/4” gas manifold of carbon steel suitable for two cylinder.
Sr.No Item Description Qty. Rate Unit Amount in Rs.
1.2 Automatic Chlorine Leak Dissolving System
SITC of automatic chlorine leak dissolving system in caustic neutralisation tank for
900 kg cylinder for chlorination system comprising of:
1) 2 nos. Leak Detection Senser
2) 1 no. Controller
3) Automatic Electric Shutoff Valve
4) CF Air blower
5) 2 nos. FRP hood for 900 kg Cl2 Cylinder
6) 1 lot flex PVC ducting line
7) 1 no. uPVC SCH 40 – diffuser
8) 1 No. relay based Control Panel
9) 1 Lot hardware, jointing & Misc. items as per required to complete the work in all
10) Construction of NaOH pond of 10000 Liter capacity
1.3 Purchasing & supplying of structure steel at site of works, with Railway freight,
loading, unloading, carting, etc. complete such as joints, channels, angles, iron rails,
etc. required for su[pport of all elec- mechanical equipment as per Tender & IS
1.4 Labour charges for lowering laying, erecting, fixing, various size of M. S. section
such as joints channel, angles plates etc. complete 50.00 13.07 Kg
B ELECTRICAL WORKS
VFD PANEL AS PER IEC 61439 (TTA Panel)
SITC of VFD & SS Panel Totally Enclosed, Floor / stand mounted, dust & vermin
proof, indoor type, minimum degree of protection - IP 42 or better as per IS:
operation on 3-Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with
instrumentation compartments accomodating LED type indicating lamps, control
contactors as per IS: 13947, CT of accuracy class- 1 as per IS: 2705, relays, meters &
control MCBs, air insulated electrolitic grade Copper bus bar for three phase &
neutral system with incomming breaker- microprocessor based Air Circuit Breakers
(electrically operated drawout type)/ MP MCCB with trip free mechanism, current
limiting type as per IS: 8828, Motor Contractor (as per type -2 coordination),
1 momentary contact type push buttons, equipment fittings, bus bars, cable gland,
incoming & outgoing cable connection for 1100V grade, Aluminium/ Copper
conductor XLPE / PVC insulated & PVC sheathed armoured cable, 10% spare
terminals, power wiring using 1100V grade, FRLS insulated copper conductor wires
conforming to IS: 694 & 8130, cable compartments / alleys of minimum 300 mm
size, GI / Al earth bus bar for entire length. panel shall be fabricated from cold
rolled, cooled annealed (CRCA) sheet steel & minimum thickness of various
members shall be as follows:
Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors: 2 mm
and Internal Partitions: 1.6 mm. or as per OEM Type tested design which ever is
Sr.No Item Description Qty. Rate Unit Amount in Rs.
Supply, installation, testing & commissioning of 415 V Fully automatic
microprocessor based Variable Frequency drive for pump control application and
general specification as under:
The VFD unit shall have modular construction, 6 Pulse Bridge rectifier, speed
control by means of sensorless vector control (open loop), high torque at low
frequencies, locking at high and low frequency settings, In-built PID control,
frequency accuracy of ± 0.1 % (min), frequency resolution of ± 0.1 Hz (min),
protections against; a) overload (motor and drive), b) short circuit, c) ground fault, d)
input / output phase loss (open circuit), e) stalling, f) input / output undervoltage
(momentary power loss restart), g) input / output overvoltage, h) over-frequency, i)
Input surge, j) over temperature of heatsink, k) loss of remote speed signal etc. The
VFD shall also have userfriendly programming software & it shall be capable of at
least two level parameter setting with password lock for critical parameters,
programming for I/Os, speed search function, copy parameters (upload / download)
to other identical unit, tuning to energy saving mode (maximum efficiency), event /
fault recording (last 5 faults in non-volatile memory) & RS 485 communication port
(MODBUS RTU protocol) with required software.
Minimum Requirement for different rating of VFD Panel:
VFD with Door Mounted Display, TM MCCB/MDO ACB as Incomer, Input and Output
Choke as per OEM Recommendation, Indication Lamp, cast resin type CT Cl-1.0,
Digital MFM, Digital Ammeter, 415V/230V AC Constant voltage/control transformer
min 500VA, A/M switch, Start Stop Push Button, Exhaust Fan, 8 channel
with 50 KVAr Fixed Type MPP Type Heavy duty capacitor shall be considered to
1.1 improve PF with aceesories like A/M switch, start-stop Pushbutton, Indicating 2 1828080 Nos.
lamps, Capacitor Duty contactors, On delay timer shall be considered as part of the
AUTO CHANGE OVER PANEL :
Supply, Installation, testing and commissioning of Auto Change Over Panel, totally
enclosed, dust & vermin proof, Indoor type, fabricated from CRCA sheet steel with
minimum thickness of 3 mm for base frame/ channel/ gland plates, 2.0 mm for load
bearing members/ doors & 1.6 mm for internal partitions, minimum degree of
protection - IP 42 or better, suitable for operation on 3-Phase, 4 Wire, 415V, 50Hz
System, Air insulated EC grade Copper busbar for three phase & neutral system, GI
earth bus for entire length, power/ control wiring using 1100V grade, FRLS insulated
copper conductor wires.
ATS with Controller with below mentioned Amp Rating, Space Heater with
Thermostate, DG start stop PB, Indication Lamps, A/M selector switch, control
wiring complete in all respect as per Tender Specificaiton and Instruction of EIC.
Sr.No Item Description Qty. Rate Unit Amount in Rs.
ISOLATOR PANEL :
Supply, Installation, testing and commissioning of Isolator Panel, totally enclosed,
dust & vermin proof, Outdoor type, fabricated from CRCA sheet steel with minimum
thickness of 3 mm for base frame/ channel/ gland plates, 2.0 mm for load bearing
members/ doors & 1.6 mm for internal partitions, minimum degree of protection - IP-
55 or better, suitable for operation on 3-Phase, 4 Wire, 415V, 50Hz System, Air
insulated EC grade Copper busbar for three phase & neutral system, GI earth bus
for entire length, power/ control wiring using 1100V grade, FRLS insulated copper
conductor wires.
Isolator with below mentioned Amp Rating, Space Heater with Thermostate,
Indication Lamps, control wiring complete in all respect as per Tender Specificaiton
and Instruction of EIC.
4 LOW VOLTAGE (LT) CABLES
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded
Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded
PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary
clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road 500 954 Mtrs.
crossing or floor as per site requirement) conforming to IS:7098 (Part-1) &
IEC:60502 (Part-1) of following sizes
3.5 Core x 300 Sqmm A2XFY Cable
4.2 3.5 Core x 185 Sqmm A2XFY Cable 100 622 Mtrs.
4.3 4C x 10 sq.mm. A2XFY Cable ( For 15 nos. street light ) 350 97 Mtrs.
4.4 2C x 2.5 sq. mm. 2XWY/2XFY(X) Cable 50 135 Mtrs.
5 CABLE END TERMINATION AND CONNECTION:
SITC of Double compression Ni-Plated brass cable glands and crimping type
Bimetallic lugs / sockets with necessary tools and equipments as specified in
specifications and IS. The glands and lugs / sockets shall be suitable for cable size
and type mentioned below & as per specifications.
1) Earthing the glands and armouring with earthing clamp and jumper and also
connecting to common earth bar.
2) The job also includes, if necessary, supply & fixing of extension busbar of same
material on MCCB or panel board terminal / connector to connect more than one no.
of parallel cables or to connect higher size cable to lower size unit. The job also
includes earthing the glands and armour of the cable with common earth bar or
flexible copper mesh.
x 300 Sqmm A2XFY
185 Sqmm A2XFY Cable
Cable (( 25 Run
VFD Panel ) 8 594 Nos.
5.3 4C x 10 sq.mm. A2XFY Cable ( For 15 nos. street light ) 32 128 Nos.
5.4 2C x 2.5 sq. mm. 2XWY/2XFY(X) Cable 4 83 Nos.
6 CABLE TRAY 50 185.00 Rmt.
Supply & laying GI perforated type cable trays with returned edge/ flange,
fabricated from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot
dipped galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including
accessories such as coupler plates/ fish plates, bends,tees, reducers, elbows,
covers and electro-galvanized hardware etc, erected on existing support as per
specification and instruction of engineer in charge.
50(W) x 25(H) x 2.0 mm Thick
Sr.No Item Description Qty. Rate Unit Amount in Rs.
7 Supply, laying and erection of 40 mm (ID) approved make Double Walled 300 64 Mtrs.
Corrugated pipes (DWC) of polyethelene (confirming to IS-14930 II) with necessary
connecting accessories of same material at required depth for laying of cable below
ground / road surface for enclosing cable and back filling the same to make ground
as per original. (For Street Light Cable)
Construction of Cable Trench in brick or bela stone masonary, locally available in
C.M. 1:6 foundation concrete 150mm thick in C.C. 1:3:6 of trap metal size 25 to 40mm
thick, inside cement plaster in C.M. 1:3 upto 1.20 Height & 0.90M Width including 50 4500 Rmt.
complete civil work ,excavation and refilling with cast in situ RCC slab in one single
piece with 230 mm thick brick masonry wall in CM 1:6
8.1 Making Trench/ excavation in soft soil of suitable width and of depth (minimum
90cm depth (LT) & 1000mm for HT) for laying cable/ DWC pipe and back filling the
same and making the surface as normal ground as per Tender Specification Or EIC.
(For laying of HT/LT cable)
8.2 Cable Protection/ Covering in Trench: Cable Covering with second class bricks
or cement tiles laid cover the cable (top) & also on both side with sand
bedding/cushioning of 75mm above and below cable.(16 bricks per meter.) as per
Tender Specification. (For HT/LT cable protection ) complete in all respects as
instructed by EIC.
Supplying & fixing Steel Chequered Plate having 7 mm thickness,duly painted with Sq.
two coats of black Japan colour. (Average Wt. 61.1 kg/ Sq.Mtr.) Mtrs.
CHEMICAL EARTHING
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make
Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having
80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded
by highly conductive compound with high charge dissipation suitable for following
9 type of applications with chamber and heavy duty cover (A)(approved make OEM
has to submit test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the value of
earthing resistane mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C)
Back fill Compound :Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency.
9.1 For Electrical Installation covering Transformer Neutrals, Lightning arrester
Earthing, Instrumentation (like PLC Panel, SCADA)i.e.independent Earthing located
in other than normal soil i.e.Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
9.2 Providing one bag of 25 kg. Additional back filling compound (BFC) suitable for safe 2 700 Nos.
earthing device.
Sr.No Item Description Qty. Rate Unit Amount in Rs.
9.3 SITC of 50mm(w) x 6mm(T) etc. sizes as required, HOT dip galvanized GI Strip 145 77 Kg.
including supply & fixing using GI spacers, saddles when laid inside the building and
inclusive of excavation & refilling of earth when laid outside the building &
interconnection with earth pit & all electro-mechanical equipments.
(50X6 G.I Strip wt.2.4 kg/m, 2.4x60Mt.=145kg.)
9.4 SITC of pipe type earthing having 150 cms long and 2.5cms dia. Galvanised iron pipe 15 365 Nos.
with coupling and buch buried in specially prepared earth pit complete with
necessary 8 SWG earth wire (For 15 nos. street light poles earthing)
10.1 EXTERNAL LIGHTING (STREET LIGHT POLE): 15 10479 Nos.
SITC of Street Light Pole, Steel tubular swaged type, 7.5 Meter long with single
arm & M.S.base plate with pipe cap and over hung 1.0 m long having dia to suit the
socket of 240V LED street light fixtures. Street light pole unit rate shall be with (i) IP
65 SMC box of size 20 x 15 x 15 cms. with MCB & terminal strip inside the box with
hinged/sliding door (ii) 50mm dia, B class GI pipe bracket min.1.5mtr long for
Incoming & outgoing cable (iii)MS Cable Clamp of 25 x 3mm (iv)SITC of
Mtr.single Arm bracket of medium duty MS pipe of 4.2 cms. Out
side dia complete with suitable sleeve tubing 45 cms. long of required size of pole
top etc. and having spread of 1.0.mtr. length with 110 deg.(v) Complete painted with
one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint for
Pole,Arm, pipe etc.
10.2 SITC of M-20 / 1:2:4 cement concrete foundation for Street light pole & 70 % PCC 15 1102 Nos.
from bottom including excavation for the pole of size 60 x 60 x 120 cms.Deep in
below ground level with plinth of 45 cms x 45 cms(or 45 cms dia x 45cms) high
upper ground level with necessary curing and finishing in approved manner.
10.3 Street Light Fitting : 15 6028 Nos.
SITC of 70W LED Street light fittings with High power White LEDs wattage of 1Watt
and above assembled on single MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/
lenses with company mark/name engraved or embossed 120 to 300 V,Power Factor
more than 0.95, THD < 20 %, CCT 5000 K to 5700K, Uniformity ratio >0.45,
Luminaries efficacy> 85 lumens/watt . LED driver
efficiency > 85 %.
( Each fittings required LM-79 & LM-80 certificates) (IP-65), Surge -4KV Cat-III
(iii) Above 60 to 90 watts
11 Supply and laying of Synthetic Insulating Mat of (440V) Class - B / min. thickness 15 763 Sq.Mtr.
2.5mm as per IS:15652/IEC61111 and with good electrical insulation property as per
site requirement. (for LT Panel)
SHIFTING / RESTORATION WORK
Dismentling of Existing starter cubical from existing Panel room / location and
12 shifting of electrical equipments and accessories to VMC store, breaking/ 1.00 25000 Job
modification of existing civil work as per site requirement and as per instrunction of
Site Engineer incharge.
Sr.No Item Description Qty. Rate Unit Amount in Rs.
13 Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar 50 41739 KW
Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized
Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-
Iron Tempered Glass (AR Coated), High efficency and positive power tolerance
Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and
Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free
Modules, Thep. temp. co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to be used. Unit
Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product
warranty and 25 year Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the DCR(Domestic
content requirements). The Ration of AC to DC is 5:6 for the Installation capacity
which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% -
98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor:
~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C, Integrated protection of
Inverter are Anti-islanding Protection, Input Reverse Polarity Protection, Insulation
Resistor Detection, Ground fault protection, Residual Current Monitoring Unit,
Output Over Current Protection, Output Short Circuit Protection, Output Over
Voltage Protection, PV array string fault Protection. Protection Degree: IP65, User
Interface LCD & APP, Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over
Current Protection Integrated, Output Short Circuit Protection Integrated, Output
Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: The
mounting (Rectangular pipe / square pipe / circular pipe) with requisite cross bars,
nuts and bolts, etc. shall be Hot deep galvanized with minimum 80micron coating.
The Rectangular / square /circular hollow pipe section used for the structure should
have a minimum thickness of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural engineer certifying the
strength and stability of the mounting structure to withstand the weight and wind
speed of 150 km/hour throughout the life span of 25 years of the system, shall be
submitted by the vendors. Hot Dipped Galvanized steel coils. suitable arrangement
for base plate for foundation , solar panel mounting, the structure should be
suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for
installtion of stucture should be (SS 304) quality.The ground clearance of the
bottom most edge of solar panel shall not be less than 300 mm to 1200 mm or as
per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balance of
14 Providing and Fixing office Furniture with 02 nos executive Tables with 02 nos 1 500000 Ls.
revolving office Chairs and 08 nos office Chairs, Computer System latest with
Printer all in one with A3 Size Scanner, 3 Nos office cupboard (6 feet H x 3.5 feet W
x 1.0 feet 4 inch D) ,3 Nos Padestal Fans, 2 Nos alluminium foldable laddder 6M long
as per instruction of EIC.
INSTRUMENTATION WORK
ITEM DESCRIPTION QTY RATE UNIT AMOUNT
1 ELECTRO MAGNETIC FLOWMETER 24V DC Powered 1.00 10,50,421.00 Nos
Supply, installation, testing and commissioning of Full Bore
Electromagnetic flow meter comprising of IP-68 Sensor , IP-66
remote type transmitter with min. 20 m armored cable between
sensor and transmitter, 4-20 mA (HART) output with Modbus
(RS485) with all mounting accessories, Weather proof outdoor(IP
55) type enclosure with glass cutout and lockable door for
transmitter, hardware, mounting stand, etc. as per specification
and to complete the work in all respect as per site condition
necessary connection with pipe including necessary modification
, cutting, welding in Exiting pipe line, maintain upstream and
downstream pipe length for flow meter as per requirement,
providing foundation and support, etc. complete as per
specification and to complete the work in all respect as per site
condition and shall have following size.
Meter Size : 900 mm (At Feeder line of Sump)
2 Uninstallation and Reinstallation of Existing Butterfly 1.00 60,000.00 Nos
valve,flowmeter,flowmeter pole,pressure transmitter with its pipe
and Reinstallation of Same as directed by engineer incharge
including shifting Cables, Conduits and retermination of same in
existing panel including Installation of Spool piece at existing
3 METALLIC EXPANSION BELLOW 1.00 57,216.00 Nos
Supply, installation, testing & commissioning of flange ends
Expansion Bellow as per EJMA standards of overall length of
minimum 300 mm, designed for 15 mm axial compression and
mm axial extension with tie rods etc. of following MOC & pressure
ratings PN - 1.6.
MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304;
Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS
1538 / IS 6392 ) & Limit Rods & Nuts: CS - IS
Meter Size : 900 mm (At Feeder line of Sump)
ITEM DESCRIPTION QTY RATE UNIT AMOUNT
4 Installation, Testing and comissioning of existing Ultrasonic Level 2.00 5,000.00 Job
Transmitter the same with core-cutting and required hardware
and along with welding/cutting work as per the instruction of EIC
after work Completion to avoid any damage during Civil activities
of GSR complete as per Specifications./drawings and as directed
by Engineer In Charge.
5 Cable Route marker for "INST. CABLES" 5.00 800.00 Nos.
Route Marker made up of 2mm thick and min. 6" dia. round ms
plate with antirust & colour coating for protection of Underground
Cables fixed in ground with RCC Foundation as per direction of
6 SITC of armored Cables,non armored cables, Cable Trays, HDPE 1.00 50000.00 Lot
PLB Duct Conduits, GI Pipes including cableing, termination, tray,
conduit work welding/cutting work etc. as per the instruction of
EIC including excavation, backfilling and restoration of site as per
actual to for powering up and fulfill communication requirement
for the instrumentation items of the project. The scope shall also
include additional SITC of cables,trays, conduits and pipes
required for connecting of existing instruments with shifted
panels supplying and laying of armored cables for existing feeder
line flowmeter, actuator and pressure transmitter to make the
complete system functional as per specifications and scope of
7.0 Supply, laying and dressing of 3 Core 1.5 sqmm copper armoured 90.00 94.00 Mtr.
cable as per tender specification and scope of work.
8.0 Supply, laying and dressing of 1 Pair 1.0 sqmm copper armoured 185.00 90.00 Mtr.
cable as per tender specification for existing instruments.
9.0 SITC of E&H ProgMag series Flowmeter transmitter only, for 1.00 60000.00 Nos
existing installed at feederline E&H make Flowmeter
ITEM DESCRIPTION QTY RATE UNIT AMOUNT
10 CHEMICAL EARTHING 1.00 10,088.00 Nos
Supplying & erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
For Electrical Installation covering Transformer Neutrals,
Lightning arrester, Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA) i.e independent Earthing in
11 normal soil.
Supply & fixing of Electrical actuator height extension including 4.00 38,309.40 Job
uninstallation of Electrical Actuator, supply & fixing of BFV Valve
shaft, MS support channel, MS mounting arrangement to install
actuator outside and above chamber, Reinstallation &
retermination of Electrical actuator and all other work to complete
work satisfactorily and other as per tender specification and
I/We am/are willing to carry out the work at… ..................... % above/below percent(Should be
written in figures and words) of the estimated rate mentioned above. Amount of my /our
tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.0 SBD- CHANNI JAKATNAKA.pdf
2.0 General Specifications-CHANNI JAKATNAKA.pdf
3.0 Electro Mechnical Specification-CHANNI JAKATNAKA.pdf
4.0 Instrument-CHANNI JAKATNAKA.pdf
5.0 Vendor List-CHANNI JAKATNAKA.pdf
6.0 Price Bid CHANNI JAKATNAKA SUMP.pdf
1.0 EXISITING GAD AT CHHANI JAKAT NAKA SUMP.pdf
2 PROPOSED GAD AT CHHANI JAKARNAKA SUMP.pdf
3.0 SUMP G.A.pdf
Download all tender documents and submit your bid