Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48 LAccepted-AOC 5TH FLOOR DP 9 P T I BLDG SALT LAKE SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹54.0 L+₹6.0 L (12.4%)Rejected-Finance 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-Finance 2nd lowest |
| Sl No | Description | Qty | Unit | KONE ELEVATOR INDIA PRIVATE LIMITED L1 | Otis Elevator Company (India) Limited L2 |
|---|---|---|---|---|---|
| 1.00Supply , Installation , Testing & Commissioning of 8 (Eight) Passengers lift as per following specification :- Make - OTIS / KONE / SCHINDLER | |||||
| 1.01TYPE : Passenger CAPACITY (Kgs) : 8 PERSONS 544 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 5th floor about 23 m STOPS : 6 Stops & 6 opening With (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt | |||||
| 1.02CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60mins HOISTWAY DIMENSIONS (W x D - mm) : 1950 mm W x 1800 mm D [Academic Bldg.-I] & 1960mm W x 1800 mm D[Academic Bldg. II] CAR DIMENSION (W x D x H - mm) : 1300 mm W x1100 mm D x 2300 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors | |||||
| 1.03DOOR OPENING (W x H - mm) : 1200 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor. | |||||
| 1.04 | STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive.
SAFETY FEATURES:
a) Over Speed Protection
b) Single Phase Protection
c) Over Load Protection
d) Phase faliure Protection
e) Terminal Limit Switch
f) Emergency Stop Switch
g) Inter Locking Switch
h) Reverse Phase Protection
i) Delocking arrangement from Loading
OPTIONS REQUIRED : Automatic Rescue operation, Voice Synthesizer, intercom. | 2 | Nos | - | - |
| 2.00Supply , Installation , Testing & Commissioning of 8 (Eight) Passengers lift as per following specification :- Make - OTIS / KONE / SCHINDLER | |||||
| 2.01TYPE : Passenger CAPACITY (Kgs) : 8 PERSONS 544 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 5th floor about 23 m STOPS : 6 Stops & 6 opening With (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt | |||||
| 2.02CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60mins HOISTWAY DIMENSIONS (W x D - mm) : 1900 mm W x 1800 mm D [Academic Bldg. I] & 1910 mm W x 1780 mm D [Academic Bldg. II] CAR DIMENSION (W x D x H - mm) : 1000 mm W x1100 mm D x 2300 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors | |||||
| 2.03DOOR OPENING (W x H - mm) : 1200 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor. | |||||
| 2.04 | STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive.
SAFETY FEATURES:
a) Over Speed Protection
b) Single Phase Protection
c) Over Load Protection
d) Phase faliure Protection
e) Terminal Limit Switch
f) Emergency Stop Switch
g) Inter Locking Switch
h) Reverse Phase Protection
i) Delocking arrangement from Loading
OPTIONS REQUIRED : Automatic Rescue operation, Voice Synthesizer, intercom, Handycap | 2 | Nos | - | - |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
5 Jun 2018, 4:00 pmClosed
Office of SE,SWEC,PWD, MIDNAPORE
Office Of Superintending Engineer South-Western Electrical Circle, PWD, PWD Compound, Midnapore-721101, Paschim Medinipur
Supply, Installation, Testing and Commissioning of Passengers lift at Academic Building I and Academic Building II of S.K.B University Purulia in the district of Purulia
2018_WBPWD_169190_2
WBPWD/SE/SWEC/NIQ03/2018-19
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.3 L
4 Sept 2025
8 May 2018
7 Jun 2018
8 May 2018
5 Jun 2018
8 May 2018
Amount
Supply , Installation , Testing & Commissioning of 8 (Eight) Passengers lift as per following specification :- Make - OTIS / KONE / SCHINDLER
TYPE : Passenger CAPACITY (Kgs) : 8 PERSONS 544 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 5th floor about 23 m STOPS : 6 Stops & 6 opening With (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60mins HOISTWAY DIMENSIONS (W x D - mm) : 1950 mm W x 1800 mm D [Academic Bldg.-I] & 1960mm W x 1800 mm D[Academic Bldg. II] CAR DIMENSION (W x D x H - mm) : 1300 mm W x1100 mm D x 2300 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
DOOR OPENING (W x H - mm) : 1200 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS REQUIRED : Automatic Rescue operation, Voice Synthesizer, intercom.
Supply , Installation , Testing & Commissioning of 8 (Eight) Passengers lift as per following specification :- Make - OTIS / KONE / SCHINDLER
TYPE : Passenger CAPACITY (Kgs) : 8 PERSONS 544 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 5th floor about 23 m STOPS : 6 Stops & 6 opening With (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60mins HOISTWAY DIMENSIONS (W x D - mm) : 1900 mm W x 1800 mm D [Academic Bldg. I] & 1910 mm W x 1780 mm D [Academic Bldg. II] CAR DIMENSION (W x D x H - mm) : 1000 mm W x1100 mm D x 2300 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
DOOR OPENING (W x H - mm) : 1200 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS REQUIRED : Automatic Rescue operation, Voice Synthesizer, intercom, Handycap
Otis Elevator Company (India) Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .