| 1 | L1₹26.6 LAccepted-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹26.6 L Quoted ₹26.8 L | L1 | Accepted-AOC L1 bidder bid accepted |
| 2 | L2₹29.7 L+₹2.8 L (10.6%)Rejected-Finance | ₹29.7 L+₹2.8 L (10.6%) | L2 | Rejected-Finance L2 |
| 3 | L3₹32.6 L+₹5.8 L (21.6%)Rejected-Finance | ₹32.6 L+₹5.8 L (21.6%) | L3 | Rejected-Finance L3 |
| 4 | L4₹35.9 L+₹9.0 L (33.7%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | ₹35.9 L+₹9.0 L (33.7%) | L4 | Rejected-Finance L4 |
| 5 | L5₹39.2 L+₹12.3 L (46.0%)Rejected-Finance DOOR NO 7 2 30 3 OPP APSEB SUB STATION OLD GAJUWAKA MARRIPALEM VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹39.2 L+₹12.3 L (46.0%) | L5 | Rejected-Finance L5 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
23 Apr 2024, 6:00 pmClosed
GE (P) (Navy) Vizag
Garrison Engineer Project Navy Vizag, HQ CE Navy Complex, Station Road, Visakhapatnam, Andhra Prtadesh-530004.Tele 0891-2546410, 2543670
REPAIR / REPLACEMENT OF UNSERVICEABLE FIRE ALARM SYSTEM AT DEPOT AREA AT NAD SUNABEDA GARRISON ENGINEER (PROJECT) (NAVY) VISAKHAPATNAM
2024_MES_646717_1
8864/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sunabeda Odisha
as per NIT/tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (P) (Navy) Vizag
₹72,000
Yes
5 Jul 2024
16 Mar 2024
25 Apr 2024
16 Mar 2024
23 Apr 2024
30 Mar 2024
16 Mar 2024 - 30 Mar 2024
Amount
(v) The contractor shall visit the sites and inspect complete fire detection & alarm system alonwith addressable system including all connected devices and ascertain the conditions of the systems in all respect before quoting their rates in tender. Contractor has to replace/repair all the defective items found at site during execution of the work for smooth functioning of the sytem. No representation/claim whatsoever arises shall be entertained during execution of work (vi) Comprehensive maintenance, checking, servicing, preventive/periodical, routine and corrective (break down) maintenance, cleaning, inspection and testing in and including repair/replacement of defective components/parts/accessories/devices of UL listed/control wiring harness shall be carried out by the authroised personnel of authorised dealer of the system and quoted rate shall deemed to include all this aspect. (vii) The contractor must maintain the system as per the regular maintenance schedule and shall be responsible for 100% functionality of the complete fire alarm and dtection system (viii) The system components shall be cleaned, recalibrate and retested if necessary to ensure continued performance and reduce the risk of component or system failure Item continued as srl item No.1.30
(ix) All relevant Tools & Plant and stationery such as attendnace register, Periocical maintenance register, log book etc required to operate, repair, servicing and to maintain the system shall be arranged by the contractor without any extra cost to the Govt. (x) All consumable items such as fuses, resistance, cleaning materials, battery acid, distrilled water, battery thimbles clamp, grease and thimbles of all sizes, PVC insulation tape, nuts,bolts and screws etc shall be provided by the contractor without any extra cost to the Govt. (xi) The regular and periodical cleaning/routine checking/testing and adjusting the detectors shall be carried out by the contractor in planned and systematic manner as per IS-2189:2208 with the help of TESTFIRE smoke & Heat Test Kit for efficient and smooth functioning of the system without any extra cost to the Govt. (xii) The contractor shall be responsible for handing over the complete fire detection and fire alrm system alonwith all devices /accessories/control wiring harness in serviceable condition at the time of completion of works duly inspected by the Engr-in-Charge jointly and inspection report of servicieablilty state of complete Fire alarm and detection system shall be submitted. (xiii) Contractor shall give the demo and training for all duty staff/user about the fire alarm system. The unit quoted rate under this item shall deemed to be included all these aspects. No claim wahatsoever arising in these regard shall be entartained by the Govt later on. (xiv) Major parts and earthwork for replacement/repairs to networking cables shall be paid under relevant items of schedule.
Supply only Supply, Installation, Testing and commissioning of Intelligent addressable Main fire alarm control panel suitable capacity for addressable integrated fire alarm system four loop, networking type with option of expandable up to four loops and consist loop cards of addressable as per UL 864 9th Edition NFPA 72 & NABL with switch mode power supply battery back up and charger with all accessories comprise the following specifications,complete all as per manufacturers instructions and as directed by Eng-in-charge.(i) Each loop card have maximum capacity 254 analogue addressble field devices in any combination of detectors/modules. and also with complete set up of LCD display, mother board, cables, battery , charger, all the spares etc Tested and proved functionally, complete including testing all as specified and as directed by Engineer-in-Charge. Make : (Supply only FC-924-US252PT, FHK2002-R3, FT924-US, FHK2001-R3, FCM2018-U3 of SIEMENS/ Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
All as per Item No.2.00 herein above but Intelligent addressable Main fire alarm control panel Two loop capacity with option of expandable up to four loops and consist two loop cards. Make : (Supply only FC-922-US252PT, FHK2002-R3, FT924-US, FHK2001-R3, FCM2018-U3 of SIEMENS/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only weather proof (flame proof instrumentation) manual call point incase of fire break glass with hammer, chain including connecting with monitor module complete all as per manufacturers instructions and as directed by Eng-in-charge. Make : (Supply only Siemens/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only weather proof type Horn / strobe operating on 24 V DC, including connecting with control module complete all as per manufacturers instructions as per existing sample complete all as directed. Make : (Supply only Siemens/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only of addressable monitor module with inbuilt isolator for monitoring the field NO/NC devices with binary coding setting dip switch including LED indication for normal and active modes as per approved UL listed complete all as per manufacturers instructions and as directed by Eng-in-charge. Make : (Supply only Siemens XTR1-M/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only addressable control relay module with inbuilt isolator for activating the notification, application of devices with supervisory facility to supervise the auxillary power supply as well as the notificaiton appliance circults binary coding setting dip switches including indication for normal working and active modes as per approved UL listed complete all as per manufacturers instructions and as directed by Eng-in-charge. Make : (Supply only Siemens XTR1-R/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only TCP/IP Module (Ethernet Module) to provide communication between local network that uses the RJ45 communcation protocol (TCP server & UDP) and fire alarm control panels complete all as per manufacturers instructions and as directed. Make : Ravel Electronics Pvt Ltd/Notifier/ Edward/Tyco/D-Link FCM 2027, Siemens or as per sample and compatible to integrate with existing system)
Supply only of 6 Port LIU fully loaded with all accessories complete as per site requirement all as directed by Eng-in-charge. Make : Legrand/Digisol/Amp/D Link LIU 6 port fully loaded NLU-FXXUXXR-06, NPL-FXDSC,-03, NAD-FSDSCSC or as per sample and compatible to integrate with existing system)
Supply only 1 G SPF modules complete all as per manufacturers instructions and as directed by Eng-in-charge Make : Alcon/Digisol/Sisco/D Link SM 1G SPF module or as per sample and compatible to integrate with existing system)
Supply only 2 meter Cat 6 patch card all as per manufacturers instructions and as directed by Eng-in-charge. Make : Legrand/Digisol/Amp/Dlink or as per sample and compatible to integrate with existing system)
Supply only SC to LC fiber patch cards 3 meter complete all as per manufacturers instructions and as directed by Eng-in-charge. Make : Legrand/Digisol/Amp/Dlink 3 Mtrs NCB-FS09D-LCSC-3 patch card or as per sample and compatible to integrate with existing system)
Supply only OFC to Ethernet convertor with a multiple interface circuit that can handle RS-232 or RS-422/485, serial interfaces and multi mode or sigle mode fiber and its etend serial transmission distance upt 2 KM complete all as per manufacturers instructions and as directed by Eng-in-charge. Make : Alcon/Digisol/Extreem/D-Link. DFE-855S-15i single mode media converter COPPER TO FIBER or as per sample and compatible to integrate with existing system)
Supply only SMPS/24 V DC power supply circuit unit complete of capacity 5 Amp rating with inbuilt battery charging circut complete suitable for Siemens make of intelligent addressable networking type Fire alarm control panels, complete all as specified and as directed by Engineer-in-Charge.Make : (Supply only Siemens/Honeywell/Apollo/Ravel or as per sample and compatible to integrate with existing system)
Supply only sealed lead acid batteries (12V, 07 AH) with the termination and connections, as required on site and as per existing sample complete all as directed. Make-Supply only from Siemens/Honeywell/Apollo /Ravel or as per sample and compatible to integrate with existing system)
Supply only MCB SP 20A, 'B' curve complete all as specified and directed Make ABB/Havells / C&S/Legrand / L&T
Supply only Stranded copper conductor, Flexible copper cable 1100 Volts grade of size 2 core,1.50 sq mm with all associated accessories, complete all as specified and as directed Make : POLYCAB/ PLAZA/ HAVELLS.
Supply only Stranded copper conductor, Flexible copper cable 1100 Volts grade of size 3 core,1.50 sq mm with all associated accessories, complete all as specified and as directed Make : POLYCAB/ PLAZA/ HAVELLS
Supply only Power surge protection devices of 5 Amp capacity, single phase, 230 Volts suitable for fire alarm panels complete all as specified and as directed
Supply only UPS system of capacity 1 KVA, 230V, single phase with 3 hours back up complete all as specified and as directed
Supply only Pipe HDPE PE100 PN10 SDR 13.6, 25mm complete all as specified and as directed
Supply only fiber cable 6 core Make : Legrand/Digisol/Amp/D link Cat No SM NCB-PS090-AUHD-06 or as per sample and compatible to integrate with existing system)
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, n.exc. 10 sqm on plan for foundations/laying of cable etc and getting out in hard /dense soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified.
Removing excavated material to a distance not exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Supply only Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with mounting arrangements suitable for Fire alarm panel complete all as specified and directed
Supply only Modular socket 16A, 2 module complete all as specified and directed Make : Anchor / Havells
Supply only Rigid non-metallic PVC of size 25 mm dia conduit inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Base Saddles, Screws Etc all as specified and directed
Supply only jointing materials (Jointing kit) and jointing the fiber cable 6 core complete all as specified and directed. Note Excavation and earthwork for tracing/repairing fault location shall be measured and paid separately.
Precision Safety Equipment Limited
SHIKHARA PROJECTS
M/S SOMANATH ENTERPRISES
newton electro technics
ASHOK ENTERPRISES
cooltech engineering services
TETRI ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .