Loading…
Loading…
Tender Value
₹1.5 L
EMD Value
₹3,000
Closing Date
27 Jun 2026, 4:00 pm6d left
Similar tender results from the same govt authority in the past 3 years.
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
REPAIR REPLACEMENT OF POWER CONTACTOR OF 90 TR CHILLAR PLANT NO II AND BUTTERFLY VAVLVES INSTALLED AT THE TERRACE OF EMERGENCY BLOCK OF GMCH, JAMMU
2026_PWDJK_313024_1
MHDJ/e-NIT 83 of 2026-27
Open Tender
Repair and Maintenance Services
10 days
gmch
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹3,000
19 Jun 2026
19 Jun 2026
29 Jun 2026
19 Jun 2026
27 Jun 2026
22 Jun 2026
19 Jun 2026 - 27 Jun 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
REPAIR/REPLACEMENT OF POWER CONTACTOR OF 90 TR CHILLAR PLANT NO II AND BUTTERFLY VAVLVES INSTALLED AT THE TERRACE OF EMERGENCY BLOCK OF GMCH, JAMMU
MHDJ/e-NIT 83 of 2026-27 Dated: 19.06.2026 Due : 27.06.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Replacement of Power Contactor of 90 TR capacity Chillar Plant No II installed at the Terrace of Emergency Block GMCH Jammu. The job includes servicing of 90 TR Capacity Chillar Plant No II by using chemical through Pump to remove unwanted dust from whole of the plant and also washing and, cleaning of air filters, drainage line cleaning etc. The job also includes washing of condenser coil using chemical wash so as to remove the accumulated impurities/dirt/blockages etc till the clear water flows out . Providing and Fitting Power Contactor 3TS49 3 pole having current rating AC-1120A and power rating 45 Kw / 60 HP by way of dismantling of old/damaged Contactor. installed at the Terrace of Emergency Block GMCH Jammu.The job includes complete Electrical rewiring of control panel and replacement of 2 No’s flow switches. Complete job includes cost of material, all kinds of taxes , charges of tools & tackles, other unforeseen materials & works required for execution of job and also involves cost of technicians, as and when required as per instructions of Engineer-in-Charge, to attend the complaints of machine 1 job Excess(+) Full Conversion INR
2 Replacement of Butterfly valves 4” dia fitted at the different locations at the terrace of Emergency Block at chiller Pipeline and 90 TR chillar plant by way of draining of all the water from the system and then removing the insulation of the pipeline near the area of the butterfly valve, removing the rusted nuts and bolts by using gas cutter and removing the valve from its installed position and providing and fitting of new Butterfly valves of same specifications i.e 100 mm dia on the pipelines with new nuts and bolts. Then insulating the area with covering of thermocol and aluminium sheet. Then filling the pipelines with water and checking for leakage and operation of the valves. Complete job includes cost of tools and tackles required for the execution of the job, material, labour, transportation and all types of taxes. 7 NOS. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_1013054.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid