Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹8.4 L+₹65,902.90 (8.48%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
7 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR / MAINT OF HT ELECTRIC SUPPLY AT MH JODHPUR IN ARMY AREA JODHPUR UNDER GE (ARMY) NO. 02
2023_MES_620650_1
82324/76/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (A) NO. 02
₹20,000
Yes
16 Dec 2023
26 Sept 2023
14 Nov 2023
26 Sept 2023
7 Nov 2023
20 Oct 2023
27 Sept 2023 - 10 Oct 2023
Amount
Excavation in trenches in soft loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes & foundation of poles, stay assembly all as specified and directed
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil ( same as soft loose & hard/ dense soil ) complete all as specified and as directed.
Removing of surplus excavated spoil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and as directed.
M&L for factory made un-reinforced pre cast concrete cable protection cover class HVP, Type 1 with peak, size 300mm x 180mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for HT UG cable protection on the top of the sand cushioning complete all as specified and as directed.
S&F of galvanized iron pipe of 100 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking out old HT under ground cable from trenches / floor / road / pipe / pole of any size and description incl joint complete all as specified and as directed.
Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 240 Sqmm x 3 core confirming to IS 7098 Part-II, suitable for earthed system complete all as direcrted. Note : 1. The end termination joint shall be measured and paid separately under respective items. 2. Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately.
Supply jointing and testing outdoor type cable end termination joint (Heat shrinkable) suitable for aluminium conductor cable of size 240 Sqmm x 3 Core, 11000 Volts grade complete all as specified and as directed.
All as srl item no 9 here-in-before but indoor type for cable size of 240 sqmm 3 core.
Supplying, fixing, jointing and testing cable jointing kit for 11KV (earthed system) grade cable for STRAIGHT THROUGH heat shrink type joint complete with jointing materials and accessories suitable for 95 Sqmm x 3 Core, 11000 Volts grade complete all as specified and as directed.
Supply and fixing cable route indicator for HT UG Cable of 11000 Volts bolted with 40 x 6 mm flat iron member of height 0.60 mtr, and 80 mm dia CI plate embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
M&L Lightning Arresters expulsion type complete with all fittings , transmission class , discharge capacity 65 kilo Amp, 11000 Volts complete all as specified and as directed.
Dismantling of cross arms, bracing, supports, clamps etc from MS structural steel sections complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete all as specified and as directed.
M&L for dry, blue colour silica gel crystal impregnated with cobalt suitable for transformer breather complete all as specified and as directed.
S&F of breather assembly complete suitable for any model of transformer rating 500 KVA to air column of conservator tank complete all as specified and as directed.
S&F of porcelain bushing for 500 KVA Transformer complete with all accessories suitable for any model of transformer complete all as specified and as directed.
Dehydration/filtration of transformer oil of Transformers & Stabilizers of various capacities installed at MH Sub Station by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is not less than 50 KV complete all as specified and as directed. Note :- (I) Test result will be recorded before & after filtration of oil.(ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.(iii)Transformer oil for topping up will be measured and paid in relavant item as required.
Supply and Filling Transformer Oil of good quality for Topping Up transformers 500 KVA & Servo voltage Stabilizer 100 KVA Capacity having dielectric strength not less than 50 KV , flash point not less than 135 degree C , having low viscosity for filling or replacing the old oil complete all as specified and as directed.
Disconnection of transformer from HT power supply, check all leakage portion at Transformer and clear all leakage to repair / replacement of gasket sheet or necessary welding if required complete all as specified and as directed. Note :Necessary required gasket sheet or gas welding are included in quoted rate
Dismantling & taking down insulator any type any size from HT pole complete all as specified and as directed.
S&F Disc type Porcelain Insulator, vitreous brown , large size with overall dimension 90x140mm clearence of hole 25.5 mm ,working pressure 11000 volts complete all as specified and as directed.
Dismantling the Existing Damaged Danger Notice plate from the HT Poles keeping away from site and M & L Danger notice plate of 1.6mm mild steel sheet , vitreous enamelled white ,with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps,bolts,nuts of approved size for HT, 25x20 mm size complete all as specified and as directed.
M & L Anti-Climbing device spike type fabricated out of MS bars ( round,square and flat) including nuts,bolts and washers and welding into two halves made to shape to suit the cross section of the pole.
Dismantling & taking down of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc complete all as specified and as directed.
Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set (consisting 12 Nos Post Insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc complete all as specified and as directed.
M&L for hard core of broken stone aggregate not exc 63mm including spreading, leveling etc in the HT switch yard / sub station area complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wires complete all as specified and as directed.
Preparing new steel surfaces and M&L for applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L Preparing newely untreated surfaces of steel and iron work, of any description and girth, not otherwise described, and treated with tar or coal tar black paint etc complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and as directed.
M&L for preparing old painted steel or iron surfaces of HT Pole of any type and description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush / emery paper etc, after disconnecting HT electric connection and apply two coat of aluminum paint over one coat of red oxide primer and writing of letter Pole / MES No etc of 10cm height with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and making all HT electric connections and testing the same complete all as specified and as directed.
Detecting of fault of under ground cable any size and description by veh mounted computerised PULSE GENRATOR fault detector system to accertain correct location of fault complete all as specified and as directed.
Replacement of UNSV Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the GI earth strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to LT Panel / DG Sets / Voltage Stabilizer / Building all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
M/s R K Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .