Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 4 | Admitted-Finance 19 PAOTA C ROAD JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Sept 2020, 6:00 pmClosed
GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
CLEANING/MAINT OF OVER HEAD TANK/UNDER GROUND SUMPS, SEDIMETATION TANK, WATER PURIFICATION PLANT AND ALLIED WORKS AT AF STN JODHPUR
2020_MES_373615_1
8175/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) NO 2 JODHPUR
As per tender docuemnts
6 documents required · 6 mandatory
₹500
Yes
GE (AF) NO 2 JODHPUR
₹60,000
Yes
29 Sept 2020
31 Aug 2020
28 Sept 2020
31 Aug 2020
26 Sept 2020
13 Sept 2020
Amount
Cleaning of over head tank with six stage process in following operation complete such as :-
Mechanized dewatering and scrubbing the surface of floor wall and cleaning sludge removal and shifting as directed.
High pressure cleaning.
Vacuum cleaning (removal of sludge by vacuum).
Anti bacterial spray and ultra violet radiation treatment etc complete all respect, as per reputed specialized process of following sizes-
Locations :- (Diamond Jubilee, Sharda park , 10 Md qtr Ratnada, Domestic area,Offrs Qtr,Tech area and Bundela Enclave)
150000 Glns cap at 18.0 Mtr staging.
100000 Glns cap at 60 feet staging.
50000 Glns cap. at 60 feet staging
25000 Glns cap at 60 feet staging at
Capacity 45000 Ltr cap at 12.0 m staging (at 750 SU)
Cleaning of under ground sumps in following operation complete such as follows
Mechanized dewatering and scrubbing the surface of floor wall and cleaning sludge removal and shifting as directed.
High pressure cleaning.
Vacuum cleaning.
Anti bacterial spray and ultra violet radiation treatment etc complete in all respect as per reputed specialized process of following sizes-
2.5 LG cap at CPH
2.0 LG cap at CPH
1.0 LG cap at CPH
15000 Glns at cap 160 cadets Pump House and at Sharda Park Pump house.
10000 Glns cap at Officer’s Mess, Tech area, 10 Md Qtrs, Map Qtrs and Sharda Park, Balsamand PH
5500 Glns cap at 56 Cadets Pump House, 05 End tube well, 33 SU PH.
Cleaning of RCC sedimentation tank in following operation complete such as-
Mechanized dewatering and scrubbing the surface of floor wall and cleaning sludge removal and shifting as directed.
High pressure cleaning.
Vacuum cleaning.
Anti bacterial spray and ultra violet radiation treatment etc complete in all respect as per reputed specialized of following sizes-
Cleaning of clarifloculator, Greasing all components by replacing the worn nut bolts of non clogging pump motor, and removing all the sludge dirt and deposits of any foreign materials etc. , painting of all the steel member canels, angles of the scrappers and mixers with two coats of bituminous based paint after preparation of old painted surface all as specified and directed by Engr-in-Charge.
100000 Glns cap at CPH (New & Old plant)
50000 Glns cap at CPH
Cleaning of RCC raw water (back wash) UG sumps in following operation complete such as-
Mechanized dewatering and scrubbing the surface of floor wall and cleaning sludge removal and shifting as directed.
High pressure cleaning.
Vacuum cleaning.
Anti bacterial spray and ultra violet radiation treatment etc complete in all respect as per reputed specialized process of following sizes-
25000 Glns cap at CPH
15000 cap at CPH
Cleaning of SWT tanks/open wells/ftns of from 5000 to 7500 GLN capacity complete all as specified and directed with the following operations such as :-
Mechanised dewatring and scrubbing the surface of floor wall and cleaning sludge removal and shifting above 100 mtr away as directed.
High pressure cleaning.
Vaccum cleaning.
Anti bacterial spray and ultra voilet rediation treatment etc complete in all respect as per reputed specilised process .
-do- all as per above item 5 but capacity 10000 Glns.
Cleaning of PVC/RCC tank in following operation complete such as-
Dewatering the water from tank, removing all silt dirt etc from insite tank and mouth of delivery pipe of the tank, there after cleaning/rubbing inner/outer surface using bleaching and fresh water and preventing leakage/ seapage from sides of inlet and out let and washout pipe complete to the entire satisfaction of Engineer -in- charge including writing the date of cleaning in 3 cm high letters on the tank of following sizes-
Exc. 4500 Ltr to 10000 Ltr capacity tank.
Replacing of existing filter media consisting of gravel and sand in filter bed having filtration capacity 187500 Ltr per hr, cleaning of filter bed, refilling of filter bed with existing groves after carrying out necessary cleaning as per details given below all as directed by Engr-in-Charge.
Removing the existing filter media consisting of grounds and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching power solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spray and ultra violet radiation treatment etc complete all respect, Anti bacterial spray and ultra violet radiation treatment, Vacuum cleaning etc complete.
Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5% concentrated solution of Hydrochloric Acid (HCL) and treatment with 10% concentrated solution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds as per details given as under :-
Filter gravels (pebbles) 1/8” to 1/4" - 0.6 Cum
-do- but 1/4" to 3/8” - 0.6 Cum
-do- but 1/2" to 3/4" - 0.6 Cum
All as per item No 7 above but filtration capacity 90000 Liters per hr and details as under :-
Filter gravels (pebbles) 1/8” to 1/4" - 0.4 Cum
-do- but 1/4" to 3/8” - 0.4 Cum
-do- but 1/2" to 3/4" - 0.4 Cum
All as per item No 7 above but filtration capacity 45000 Liters per hr and details as under :-
Filter gravels (peddles) 1/8” to 1/4" - 0.15 Cum
-do- but 1/4" to 3/8” 0.15 Cum
-do- but 1/2" to 3/4" - 0.15 Cum
All as per item No 7 above but filtration capacity 43000 Liters per hr, opening/refixing of the main hole cover and bottom cover of swimming pool filter plant including painting as per approved engr in charge complete and details as under :-
Filter gravels (peddles) 1/8” to 1/4" - 0.40 Cum
-do- but 1/4" to 3/8” - 0.40 Cum
-do- but 1/2" to 3/4" - 0.40 Cum
-do but 3/4” to 1 ½” - 0.25 cum
-do but 1 1/2” to 2 - 0.25 cum
All as per item No 7 above but filtration capacity 40000 Gln per hr, opening/refixing of the main hole cover and bottom cover of carbon active filter plant including painting as per approved Engr in chargeand details as under :-
Filter gravels (peddles) 1/8” to 1/4" - 0.10 Cum
-do- but 1/4" to 3/8” - 0.10 Cum
-do- but 1/2" to 3/4" - 0.10 Cum
-do but 3/4” to 1 ½” - 0.05 cum
-do but 1 1/2” to 2 - 0.05 cum
All as per item No7 above but filtration capacity 20000 Liters per hr and details as under :-
Filter gravels (peddles) 1/8” to 1/4" - 0.10 Cum
-do- but 1/4" to 3/8” - 0.10 Cum
-do- but 1/2" to 3/4" - 0.10 Cum
NOTE FOR ITEM NO 7 TO 12 : Additional sand and pebbles of different sizes required for refilling into filter bed shall be paid separately as material only under relevant item.
Supply only for filling the following filter media in filter bed duly cleaned and washed with 5% concentrated solution of HCL and treatment with 10% concentrated solution of NAOH all as directed by Engr-in-Charge.
Filter gravels (pebbles) 1/8” to 1/4".
-do- but 1/4" to 3/8”
do- but 1/2" to 3/4"
-do- but ¾” to 1 ½”
do- but 1 ½” to 2"
Filter sand of size 1/32” to 1/16”
Repair/remarking to existing scale and indicator (water level indicator of RCC UG reservoir or over head reservoir) with synthetic enamel paint as per colour code and as directed by Engr-in-Charge.
Replacement of PVC floats of size 300mm with pvc wire, red paiting iron plate as per existing size including changing of nilon rope etc complete as directed in all RCC over head reservoir or UG reservoir.
Replacement of PVC ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, of following sizes prayag or equivalent ISI make as specified and directed :-
15mm dia bore
20 mm dia bore
25mm dia bore
40 mm dia bore
50 mm dia bore
Material and labour for overhauling , greasing ,etc of HOT crane capacity 2 ton including painting of iron grader ,angle, chain complete entire satisfaction of Engr in charge.
18. Material and labour of compressor oil servo friz-140/ sunol -140 including washout from compressor oil in compressor of any capacity to entire satis faction of Engr -in -charge.
Material and labour for repairing to compressor of blowing filtration capacity 187500 Ltr per hr for overhauling , greasing by disconnecting the existing connections, replacement of Oil seal packing, rubber packing, cleaning of rotor assembly and replacement of unserviceable bearings and refixing the same including commissioning and testing complete.
S & F fire Retardant/extinguishing Elect. insulated synthetic mat insulation “2000” of 2.0 mm thick ± 10% confirming BIS DOC No- ET- 02 Dt.30/4/2004,meeting requiremnts of IS:3043,IS: 5216 (Part I, II & III), IS 8437 & IEC 479 Pub- 01. Tested for break down strength of insulation resistance, effect of acid, alkaline, diesel, transformer oil, leakage current and fire test etc, including hardener special PVC adhesive liquid primer as required as site, suitable for and upto 3.3 KV AC and 220 volt DC system without HT, all as directed by Engr-in-Charge including removing old mat. Make-Suntex Enterprises
M&L for replacement of CI suction/discharge pipe for over head head tank and painting to outside portion with two coats of anti corrosive paint over a coat of red oxide primer all as directed by Engineer-in-Charge.for various place of following sizes-
250 mm bore flange type
200 mm bore
150 mm bore flange type
M&L for repiaring of PLC based pump automation and protection panel for water supply repaire/replacement of indicator lamp 230 Volt,audio signal generator complete at CPH.
M&L for repairing of Digital indicator of water level for over head tank at various places.
Material and labour in repair for over hauling/ lubrication emtork actuator valves Model No : M1/030/A and M0/030/E including replacement of unserviceable spare parts at CPH area make Marsh, three phase, TEFC type motor, DOl starting complete entire satisfaction of Engr in charge.
Supply only actuator stroke( Stainless Steel spindle 2.4 mtr long). Make – as per sample.
Supply only coupling piece . Make as per sample.
Supply only spur gear Box . make as per sample.
Supply only Torque switch. make as per sample.
Supply only Travel switches.make as per sample.
Supply only torque switch operating cam.make as per sample.
Supply only locking plate.make as per sample.
Supply only Eccentric pins.make as per sample.
Supply only Allen bolts- M8x100L. make as per sample.
Material and labour in repair for over hauling/ lubrication of flow meter including replacement of unserviceable spare parts at CPH complete entire satisfaction of Engr-in-Charge .
Supply and fixing cast iron sluice valve heavy duty class PN1.6 flanged ends any pattern with head wheel and brass spindle ISI marked conforming to IS with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts bolts, washers, rubber flange including taking out of existing unserviceable one complete all as specified of size 350 mm bore.Make: Kirloskar, Leader, KSB
Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
Dismantling and taking out old unserviceable aluminium air termination rod any type any size from existing RCC over head tanks. Note :- The rate quoted by the contractor shall include the necessary scaffolding arrengement and insurance to working staff for working on RCC over head tanks.
Dismantling and taking out old unserviceable test point terminal block.
Dismantling and taking out old unserviceable aluminium strip.
S & F epoxy insulators with necessary fixing arrangements on the roof/wall/beams all as directed & specified.
Supply and fixing Air terminations Single Pointed copper rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 X 75 X 25 mm , drilled and screwed including 3 nos 8 mm dia 25 mm hexogonal head Screw as specified & directed.
Supply and fix Copper Strip 20 x 3.15 mm working height up to 7.5 mtr as continuous earth lead from Copper air termination rod to test point terminal as down conductor, roof conductor and continuous earth lead to test point terminal all as directed . Note:- All the jonts shall be made with copper brazing to get proper conductivity.
-do- but working height above 7.5 mtr and up to 25 mtr. (Sec 1 General rule1.14.3)
Supply and laying GI tubing 40 mm dia light grade laid in trenches/floor/fixing on pole / wall / in tarmac including necessary fittings etc.complete& all as specified and directed.
Taking down old U/S aviation obstruction light from OH tank of staging upto 20 mtrs and supply & fix aviation light,type 91951581000-1 with - LED lamp model XGP 4001x LED - K2 / RD 240 Volts.
Supply and fix in replacement on pole, in trench, on floor and on over head tanks up to the height 7.5 mtr cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100 Volts grade with stranded aluminum conductor of size 2 core 10 sqmm. including taking up/down the old. Note :- Excavation and earth work shall be measured and paid for separately under relevent item.
M&L for earthing complete with copper earth plate electrode 60 cm x 60cm x 3.15mm thick buried directly in ground not less than 2.25m deep below ground level with top of the plate not less than 1.5m below ground level connected to the copper strip 20 X 3.15 mm as earth lead by means of bolts nuts, check nuts and washer of copper/brass including necessary earth work PCC 1:3:6 type C2 earth chamber, RCC cover (instead of CI frame and cover) etc complete all as shown in plate No 5 of MES schedule part I including testing on completion.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth and getting out in soft/loose soil.
. Returning filling in including spreading leveling, watering and well ramming in layers not exc 25cm in soft/loose soil, hard dense soil.
Removing the excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point.
M & L for sand cushioning to UG cable laid in trenches with clean dry river sand obtained from the river near Surendranagar all as directed.
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as directed.
M & L surfaces painting of external water supply pipe line of any size with two coat of synthetic enamel paint as directed by Engr-in-Charge. Note:- (a) The rate quoted by the contractor shall include the necessary scaffolding arrangement and insurance to working staff for working on RCC over head tanks, UG Sumps. (b) Writing the cleanin date is block letter exc 30 cm on over head tanks and UG sumps.
Pre-cast cement concrete block massonary with solid blocks exc 10cm width and setting in CM 1:6 ,Type C1,PCC 1;3:6 using 20 mm stone aggregate complete for valve chamber and header etc. as specified and directed.
M&L for PCC 1:4:8 Type D2 using 40 mm graded aggreded in foundations of valve chamber and header etc.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggreded for coping of valve chamber and header etc.
M&L for rendering 15 mm thick on fair faces of stone massonary in CM 1:4 complete.
M&L for MS work for clamps, plate covers of valve chambers fabricated from structural steel incl nuts,bolts,welding, bending, drilling etc complete all as darected incl painting over a coat of red oxide including dismentaling of old rusted MS work.
S & F in replacement on overhead tank wire netting of stainless steel wire 1.4 mm dia fixed with tinned tacks of stainless steel wire staples , (size of wiremess 12mm ) incl necessary stainless steel bracket in any length and fixing acessories like PVC plugs , brass screws etc.
Rajendra Engineering Works
M/s. Dhananjay Construction
L C ASSOCIATES
TRIVENI ENTERPRISES
ABHOG INFRASTRUCTURE PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .