Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC 23 144A ADHIKARATHU PARAYIL KALAVOOR P O VALAVANAD MANNANCHERRY ALAPPUZHA KERALA 688 522 | ALAPPUZHA | ALAPPUZHA | KERALA | 688522 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹30.0 L+₹400 (0.01%)Rejected-Finance NO 9 82 IB CHAKKALAKAL SOUTH CHITTOOR P O ERNAKULAM DIST KOCHI 682 027 | KOCHI | ERNAKULAM | KERALA | 682027 | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹30.2 L+₹19,600 (0.65%)Rejected-Finance 12 SUKUN RAW HOUSE NEW RANDER ROAD GORAT ADAJANPATIA SURAT GUJARAT 395005 | SURAT | GUJARAT | 395005 | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹30.7 L+₹68,465 (2.28%)Rejected-Finance | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹31.2 L+₹1.2 L (3.88%)Rejected-Finance BLDG NO 02 ALACKAPARAMBIL THODAYIL THURAVOOR THEKKU THURAVOOR POST ALAPPUZHA KERALA 688532 | ALAPPUZHA | ALAPPUZHA | KERALA | 688532 | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹48.1 L
EMD Value
₹96,200
Closing Date
5 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2024_MES_672527_1
8360_GE_NW
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹96,200
Yes
16 Dec 2024
6 Sept 2024
7 Oct 2024
6 Sept 2024
5 Oct 2024
21 Sept 2024
6 Sept 2024 - 28 Sept 2024
Amount
M&L for preparing old decorated plastered surfaces of wall and applying one coat of white wash upto and incl 4th storey complete all as specified and directed.
All as per Item No 1 above but from Vth to VIII the storey
All as per Item No 1 above but from IX to XII th storey
M& L for preparation of old decorated plastered or un plastered surfaces of ceiling and applying one coat of white wash upto and including 4th storey complete all as specified and directed.
All as per Item No 4 above but from Vth to VIII storey
All as per item No 4 above but from IX to XII th storey
All as per item No 4 above but XII th storey and above
M&L for preparation by washing, rubbing down and stopping of old distempered and painted wall surfaces and applying one coat of acrylic washable distemper upto and incl 4th storey complete all as specified and as directed.
All as per item No 8 above but from Vth to VIII storey
All as per item No 8 above but from IX to XII storey
All as per item No 8 above but from XIII storey and above
M&L for preparation by washing ,rubbing down and stopping of distempered and painted surfaces of ceiling and applying one coat of acrylic washable distemper any storey complete all as specified and as directed.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint upto and including IV th storey all as specified and as directed.
All as per item No 13 above but from Vth to VIIIth storey
All as per item No 13 above but from IX th to XIIth storey
All as per item No 13 above but from XIII th storey and above
M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint upto and including IV th storey all as specified and as directed.
All as per item No 17 above but fromVth to VIII storey
All as per item No 17 above but from IX th storey and above
M&L for complete removal of existing treatment of wall and applying two coats of acrylic washable distemper over and incl a coat of primer as preparatory to receive distempering upto and incl 4th storey complete all as directed.
All as per item No 20 above but from Vth to VIIIth storey
All as per item No 20 above but from IX th to XII th storey
All as per item No 20 above but XIII storey and above
M&L for preparation by washing rubbing down and stopping of old treated surfaces of wall and applying one coat of cement base paint white/tinted in any storey/ in any position complete all as specified and directed
M&L for complete removal of existing treatement of wall and applying two coats of antifungal paint over a coat of primer on plaster surfaces, preparatory to receive antifungal paint complete all as directed
M&L for preparation of old treated surfaces of wall and applying one coat of exterior antifungal paint complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width and girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
M&L for preparation of new steel surfaces of any description not exceeding 10 cm width and girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
M&L for complete removal of old steel surfaces of any description not exceeding 10 cm width and girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
M&L for preparation of old treated wooden surfaces of any description over 10 cm in width or girth and applying one coat of synthetic varnish complete all as specified and directed Note for Item Nos 1 to 30: The quoted rate shall be inclusive of necessary scaffolding for the height mentioned in respective items
M&L for writing letters or figurers (Block Roman, Italic, or Indian) n exc 30cm height complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F 4mm thick Sheet glass one side frosted, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge.
S&F 4mm thick plain Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified
M&L for repair to aluminium window of any size, pattern and any number of shutter & making good and functional including changing of pivot,repairs to lock, handle, rubber beadings etc. all as directed
M&L PCC 1:2:4 type B-1,using 20mm graded stone aggregate for fixing holdfast including necessary form work
Demolition of cement concrete of any description and in any position not otherwise specifically provided for
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; conforming to Fe-290 Gde E-165 complete all as specified and as directed
Taking down cement plastered on Brick/Concrete wall and ceiling including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10mm thick on brick or concrete wall surfaces with cement mortar (1:4) and wick @3% by weight finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of ceiling surfaces finished even and smooth complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10mm thick on brick or concrete wall surfaces with cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for Liquid water proofing compound complete all as specified and as directed by Engr-in-Charge.
M&L preparation of new plastered surfaces of ceiling including cornices and applying three coat of white wash complete all as specified and as directed
M&L preparation of new plastered surfaces of walls including cornices and applying two coat of acrylic exterior emulsion paint over a coat of suitable exterior primer complete all as specified and as directed
Removal of vegetation /shrubs on inaccessible roofs or protections etc. and spraying of acid of required qty complete from any location of building and making good disturbed surfaces with cement mortar 1:4 or cement concrete 1:3:6 type C1 , using 20mm graded aggregate including necessary scaffolding complete all as specified and as directed.
M&L for Rehabilitation for minor cracks in following 05 stages:- (i) Removing cover concrete portion in the structural elements carefully with mechanical arrangements and hand chiselling, clean the loose dust and clean the reinforcement (ii) Applying anticorrosive coating Nitrozinc primer manufactured by M/s Fosroc Chemicals or equivalent, including providing sacrificial Zinc anode Galvashield XPI before application. (iii) Applying epoxy based bond coat Nitrobond EP manufactured by M/s Fosroc or equivalent as per manufactures instruction (iv) Preparation of Polymer modified mortar by mixing 3 litres of Nitrobond SBR manufactured by M/s Fosroc chemicals or equivalent as per manufactures instruction per bag of cement in cement and sand mortar 1:3 and rendering with trowel . (v) Membrane curing by 'Concure' manufactured by M/s Fosroc chemicals or equivalent up to 4th storey
M&L for Micro concreting in RCC columns and Beams including chemicals, reinforcement, form work averaging thickness not exceeding 100 mm as in following stages ( Upto 4th storey) :- (i) Support the slab and beam which is contributing the load for the column under rehabilitation. (ii) Remove the damaged concrete portions completely (till the reinforcement is exposed from the member) carefully with mechanical arrangements or hand chiselling and clean the dust particles. (iii) Anchoring shear connectors in the form of 'L' shaped bars of 10 mm dia HSD in to the existing concrete by drilling holes not less than 75 mm depth 12 mm dia in staggered position along the perimeter and height of member. Spacing shouldn't be less that 300 mm for all sides. Before anchoring clean the holes with Jet compressed air to remove dust particles and anchor the dowel bars serve as shear connectors with chemical resin capsules manufactured by M/S Fosroc chemicals or equivalent. (iii) Clean the reinforcement and apply Nitrozinc primer manufactured by M/S Fosroc chemicals or equivalent with providing sacrificial Zinc anode Galvashield XPI (iv) Providing leak-proof shuttering system for the jacket portion of the members and micro concrete with Rendroc RG manufactured by M/S Fosroc chemicals or equivalent( compressive strength of Micro concrete should be 45 MPa at 28 days) Note: Reinforcement shall be measured and paid in connected item separately
S&C ENTERPRISES (BID ID -3118190)
M-TECH ENGINEERS (BID ID -3115277)
T K BUILDERS (BID ID -3111692)
SAGA ENGINEERS (BID ID -3119535)
AS ENTERPRISES (BID ID -3119584)
ST ANTONY CONSTRUCTIONS (BID ID -3118974)
Aarjay Tech Engineering (BID ID -3111980)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .