Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.0 CrAccepted-AOC COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | ₹1.0 Cr | L-1 | Accepted-AOC As quoted lowest L-1 Bidder |
| 2 | L-2₹1.1 Cr+₹7.8 L (7.75%)Rejected-AOC POST OFFICE ROAD DHARMANAGAR DHARMANAGAR NORTH TRIPURA | NORTH TRIPURA | TRIPURA | 799250 | ₹1.1 Cr+₹7.8 L (7.75%) | L-2 | Rejected-AOC As quoted 2nd lowest |
| 3 | L3₹1.2 Cr+₹16.2 L (16.1%)Rejected-AOC GOPINAGAR BISHALGARH SEPAHIJALA PIN 799102 | BISHALGARH | SEPAHIJALA | TRIPURA | 799102 | ₹1.2 Cr+₹16.2 L (16.1%) | L3 | Rejected-AOC As quoted 3rd lowest |
| Sl No | Description | Qty | Unit | Asish Debnath | NIKHIL DAS | Bimal Debnath |
|---|---|---|---|---|---|---|
| .10Schedule- 1 (Supply) | ||||||
| 1.10 | 12-mt long Galvanished Pole | 56 | No | 10,63,944 ₹12,55,453.92 Lowest | 11,86,440.64 ₹13,99,999.96 | 13,16,000 ₹15,52,880 |
| 1.20 | 9-mt long Steel Tubulor Pole (SP-30) | 26 | No | 2,73,000 ₹3,22,140 | 2,42,372.78 ₹2,85,999.88 Lowest | 4,55,000 ₹5,36,900 |
| 1.30 | M.S. Stay set [HT] | 45 | Set | 33,750 ₹39,825 | 27,000 ₹31,860 Lowest | 63,900 ₹75,402 |
| 1.40 | Stay insulator (HT) | 45 | No | 2,250 ₹2,655 | 1,529.1 ₹1,804.34 | 1,350 ₹1,593 Lowest |
| 1.50 | GI Stay wire 7/4 mm | 225 | Kg | 11,250 ₹13,275 Lowest | 16,875 ₹19,912.5 | 22,500 ₹26,550 |
| 1.60 | Galvanished Ch. 100 x 50 x 50 x 6 mm | 95.6 | Kg | 9,082 ₹10,716.76 | 7,648 ₹9,024.64 Lowest | 9,560 ₹11,280.8 |
| 1.70 | Galvanished Ch. 75 x 40 x 40 x 6 mm | 2,190 | Kg | 2,08,050 ₹2,45,499 | 1,75,200 ₹2,06,736 Lowest | 2,19,000 ₹2,58,420 |
| 1.80 | Galvanished Angle 65 x 65 x 6 mm. | 1,108 | Kg | 1,05,260 ₹1,24,206.8 | 88,640 ₹1,04,595.2 Lowest | 1,10,800 ₹1,30,744 |
| 1.90 | 11 KV Polymeric Disc insulator [45 KN] | 302 | No | 45,300 ₹53,454 Lowest | 60,400 ₹71,272 | 60,400 ₹71,272 |
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
8 Oct 2025, 10:00 amClosed
Dy. General Manager,ED Kailashahar
Gournagar, Kailashahar, Unakoti Tripura
Renovation of 11 KV Dedicated Feeder IBBFL and line connectivity from 33 KV Sub-station Tillabazar, kailashahar to Power connectivity at Tillabazar, Ranguati, latiapura, maguruli, Hiracherra and Sartlongbari BOP(s) including 11 KV Dedicated IBBFL
2025_POWER_65871_1
DGM/ED-KLS/2025-26/02
Open Tender
Electrical Works
Percentage
Kailashahar
Please refer Tender documents.
8 documents required · 8 mandatory
₹10,000
₹2.5 L
6 Dec 2025
23 Sept 2025
9 Oct 2025
23 Sept 2025
8 Oct 2025
23 Sept 2025
Schedule- 1 (Supply)
12-mt long Galvanished Pole
9-mt long Steel Tubulor Pole (SP-30)
M.S. Stay set [HT]
Stay insulator (HT)
GI Stay wire 7/4 mm
Galvanished Ch. 100 x 50 x 50 x 6 mm
Galvanished Ch. 75 x 40 x 40 x 6 mm
Galvanished Angle 65 x 65 x 6 mm.
11 KV Polymeric Disc insulator [45 KN]
11 KV Polymeric Disc fittings.
11 KV Polymeric composite Pin insulator
11 KV Covered Conductor 70-Sq.mm (Weasel) Triple layer type
GI wire (8 SWG)
LA - 9 KV 5 KA (set of 3 no)
11 KV GOS (3 phase Porcelin type)
11 KV DOF (3 phase Porceilin type)
Cut Out [200 A]
ACSR Weasel (30 sq mm) Conductor
PVC Cable 70-sqmm
PVC Cable-120-sq.mm
60-Kg Salt & 55-Kg Charcoal for earthing (1-Pit)
2.5-mt long 40-mm dia G.I.Pipe (TATA/JINDAL)
Wooden plank (Gamai/Karai)
Bi-Mettalic Lugs-120-sq.mm
PVC Pipe 1" size
11-KV Grade 3Core XLPE Cable 3CX185 Sq.mm
11-KV Heat shrikable Straight through Type XLPE 3 Core 185-Sq. mm Jointing kit
11-KV XLPE Cable jointing kit 185-Sq.mm, Outdoor
Stay clamp of MS Flat (50x6-mm)
Bracket clamp of MS Flat (50x6-mm)
Nuts & Bolts (assorted) size
First Class bricks
Fine sand
HDPE Pipe 200 mm dia Wall thickness minimum 11.8 mm, maximum 13.1 mm
Erection of 12-mt length of Galvanished Pole at any kind of soil upto a depth of 1/6 th of pole height including excavation of earth refilling the pit with soil upto the ground ;level ramming & making complete in all respect
Erection of 9-mt length of S.T. Pole at any kind of soil upto a depth of 1/6 th of pole height including excavation of earth refilling the pit with soil upto the ground ;level ramming & making complete in all respect
Erection of Stay set direct in earth complete with 19mm x 1800mm long stay rod,anchor plate of size 300x300x8-mm thimble,turn buckle,7/3.15 mm dia G.I.Stranded stay wire & stain sulator etc. with supply of M.S.Clamp, Nuts & bolts etc as reqd and making complete in all respect
Erection of M.S.Channel Cross-Arm 2.8-mtr long 100x50x50x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 0.8 -mtr long 100x50x50x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 2.8-mtr long 75x40x40x6 mm for GO,DO & LA (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm 2.8-mtr long 65x65x6 mm (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 0.3 mtr long 75x40x40x6 mm for S.P.Top bracket (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 1.2 mtr long 75x40x40x6 mm for S.P Bottom bracket (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm 1.6-mtr long 65x65x6 mm for S.P.Guard (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 1.7 mtr long 75x40x40x6 mm for D.P.Top bracket (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm 2.2 mtr long 75x40x40x6 mm for D.P Bottom bracket (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm 2.5-mtr long 65x65x6 mm for D.P.Guard (Excluding the cost of Back clamp, Nuts & Bolts)
Erection of 11 KV single Disc insulator set along with necessary fitting
Erection of 11 KV Pin insulator along with Pin
Laying & stringing of 1KM (Single conductor) ACSR 6/1/2.59 mm dia WEASEL including hoisting & binding etc complete as reqd.
Laying & stringing of 1KM (Single conductor) G.I.Wire 8-SWG including hoisting & binding etc complete as reqd.
Laying & stringing of 1KM (Single conductor) 11-KV Covered conductor including hoisting & binding etc complete as reqd.
Erection of 9 KV, 5 KA Single pole metal oxide gapless type LA including necessary connection complete as per technical specification
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & bolts)
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification (Excluding the cost of back clamp, Nuts & bolts)
Laying of 1-Number PVC insulated and PVC sheathed/XLPE Power cable of 11 KV grade of 185-Sq.mm size direct in ground including excavation, sand cautioning Protective covering and refilling the trench as reqd. Trench Size Width-350 mm , height-1200 mm/ sand cautioning H-250-mm, W-350 mm / Protection doble layer Bricks
Laying of 1 Number PVC insulated and PVC sheathed XLPE Power cable of 11 KV grade of all size in the GI Pipe/HDPE for riser including tieup of pipe with poles by the help of MS flat clamp as reqd
Laying of 1 Number PVC insulated and PVC sheathed XLPE Power cable of 11 KV grade of all size in the RCC/HUME/METEL pipe as reqd
Providing of Pre-cast cement concrete cable identification route marker (1-cement : 2 coarse sand : 4 graded stone aggregate 6 mm nomial size)
Installation/positioning of 11/0.433 KV 3-Phase 100- KVA of distribution Transformer on pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing
Erection of 11 KV protective guarding by GI wire 8 SWG as per technical specification across road/river/Telecom line etc in horizontal formation complete
Supply & erection of substation fencing with erection of 6nos 2.50m long ( 65 x 65 x 6mm) Angle post and 4nos( 50 x 50 x 6mm)angle post with grouting of vol 0.045cum at the ratio of 1:2:4(1cement :2R. sand : 4 jhamabrick aggregate) per post. The fencing should be made 9 horizontal line of barbed wire and one gate with shutter (2 x 1.7)m i/c locking arrangement etc complete as per diection of the Engg. in charge.
Fabrication of X-arm by MS Angle/MS Channel as per specification
Earthing with G.I.Pipe 2.5 mtr long & 40 mm dia including excvation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, GI Wire, Nuts & bolts etc as required)
Carriage of 11/0.433 KV 3 Phase 100 KVA by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
Carriage of 11/0.433 KV 3 Phase 100 KVA by Mechnical Transport from the MMD store yard, Agartala to Work site including loading, unloading &as reqd. Upto lead range 165 KM
Carriage of 8/9-mtr long Galvanished pole by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
Carriage of 12-mtr long S.T. pole by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
Carriage of steel materials,ACSR,GI Wire,GOS & DOF LA etc by Mechnical Transport from the Sub-Divisional store yard to Work site including loading, unloading &as reqd. Upto lead range 25 KM
Grouting of 9-Mtr long S.T. Pole (1-Cement : 2-coarse river : 4-graded stone) = .273-cum/Pole
Sub-station Name plate in/c supply as directed by Engg-in-charge
Maintaining adequate clearence from overhead live conductors by Trimming of tree branches for way leaves
Dismentalling of 1 KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including coiling etc complete as required
Straightening of 9-mt long S.T. Pole
Re-adjustment of Stayset complete without dismentalling of turn buckle
Re-stringing of conductor (ACSR 6/1/2.59-mm) including binding,hoisting & jumpering etc as reqd
NIKHIL DAS
Bimal Debnath
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .