Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹9.9 L+₹87,050 (9.61%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹10.0 L+₹91,863 (10.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹13.8 L+₹4.7 L (51.9%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
28 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/Replacement of LT electric supply network and misc works at Upper Garrison at YOL CANTT
2022_MES_572355_1
GE/Y-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (KH) YOL
₹20,000
Yes
9 Feb 2023
31 Dec 2022
30 Jan 2023
31 Dec 2022
28 Jan 2023
14 Jan 2023
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 08:- Excavation and earth work, sand cushioning & cable cover shall be measured and paid separately.
Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50M and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Laying only retrived bricks as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Sand cushioning to under ground cables, 8 cm thick layer before laying and testing the cable and 15 cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Mild steel galvanised light grade 80mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Cleaning of installation area from inside and outside by removing bushes, shurbs, grass and other vegetation materials by screaching out earth surface, cleaning the fungus formation and nearby growth of wild vegetation, bushes to a distance of 50 metres away all as specified and directed.
Supply and fixed in repair of single pointed air termination copper rod 12mm dia, 300mm long having one end flat with one 10mm dia hole fixing on roof top including fixing/fitting of termination rod at one end of GI pipe 25mm dia stand post with the help of nuts, bolts etc and making connection with roof/down conductors and making fixing arrangement of air termination rod over the GI pipe along with aluminium strip etc. all as specified and as directed.
Aluminium strip 25 x 3.15mm fixed on roof, pillars, wall etc, including porcelene isolater having not less than 50mm height with screws & saddles and placed at an interval not less than 50cm in such a manner that strip shoulde not touch the wall /roof/pillar surface etc,. for roof conductors and down conductors above ground above roof/wall/pole, complete fixed in repairs all as specified.
Triming of tree branches after taking shut down from power house, 1.0 metre apart from HT/LT line carefully and considering the span from pole to pole, complete with cleaing the whole area grabbed by the trimed branches of tree, complete all as specified.
Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 12 No's post insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 200 amps capacity including taking down unservicable air break gang operated switch complete, all as specified and directed.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of HT/LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm, 45cm long and errected in ground in such a way that it is 15cm above ground level and 30Cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcmm complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, including taking down old wire complete all as specified.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old poles any length, complete all as specified and directed. Note: Excavation & earth work and PCC shall be measrued and paid separately.
MCCB 4 pole with fixed adjustable thermal and fixed magnectic release, 400 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with thermal and fixed magnectic release, 160 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with thermal and fixed magnectic release, 100 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with thermal and fixed magnectic release, 63 Amps having rupturing capacity 25 KA, including taking out old, complete all as specified and directed.
Digital voltmeter of size 96x96sqmm, flush mounted type, 03 phase, class 0.5 fixed in repair complet all as specified.
Digital Ampere meter flush mounted, 03 phase, class 0.5, fixed in repair, complet all as specified.
Lamp indicator flush mounted type model 03 phase, class 0.5 fixed in repair complet all as specified.
M&L for fabrication of street light bracket made out of GI pipe 40mm dia medium grade GI Pipe minimum 1.5m long including fixing with 02 Nos MS clamps made out of flat iron of size 30mm x5 mm with nut bolts and washer incl painting work complete all as specified and directed Including taking down old one.
Stay assembly complete with MS stay Plate 300X500X6mm thick galvanised stay rod 20mm dia 2.15m long with galvanised bow, galvanised thimble, stay clamp etc. complete all as shown on electrical Plate No.01 of SSR Part-I, including taking down unservicable stay complete, all as specified and directed. Note (excavation, earthwork, PCC work, loop type insulators and stay wire shall be measured and paid separatly.)
Galvanised stay strand strand, 7/4mm dia, complete all as specified.
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5mm, including taking down existing unserviceable complete all as specified.
Plain cement concrete M-7.5 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundation of poles, stays etc. as mass concrete, complete all as specified.
Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded crushed stone aggregate as in foundation of poles, stays etc. as mass concrete, complete all as specified.
Plain cement concrete M-15 nominal mix, type B-1 using 20mm graded crushed stone aggregate as in coping of pole including necessary form work, complete all as specified.
Excavation in trenches n.exc 1.5 metres wide and exc 1.5 metres and not exc 3 metres deep and getting out in any type of soil, all as specified.
Aluminium thimble 150mm fixed in repair complete all as specified.
Aluminium thimble 120mm fixed in repair complete all as specified.
Aluminium thimble 95mm fixed in repair complete all as specified.
Aluminium thimble 75mm fixed in repair complete all as specified.
Aluminium thimble 35mm fixed in repair complete all as specified.
Aluminium thimble 25mm fixed in repair complete all as specified.
Replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
smc engineering company
M/S JATINDERA ENTERPRISES
Eshaan Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .