Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Jun 2020, 6:00 pmClosed
Chief Executive Offier Cantonment Board Dehradun
Office of Cantonment Board Dehradun
Supply of LED Building Light Street Light LED Bulb 15 Watt 17 Watt LED Batten 15 Watt 21 Watt LED Fixture 70 Watt and 90 Watt for Cantonment Board Dehradun
2020_DGDE_560870_1
XIV/12/Misc Tender/
Open Tender
Electrical Goods/Equipment
Supply
365 days
Cantonment Board Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Chief Executive Officer Cantonment Board Dehradun
₹80,000
19 Aug 2020
26 May 2020
17 Jun 2020
26 May 2020
15 Jun 2020
26 May 2020
Amount
Supply of LED Building Light & Street Light (LED Bulb 15 Watt & 17 Watt ,LED Batten 15 Watt & 20 Watt, LED Fixture 70 Watt & 90 Watt
70 Watt LED make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves,Havells,Osram,) - specifications- 1.1. Electrical Specifications ( LED Driver)-Input Voltage: AC 140 to 270 V AC with Auto resetting Safety Cut-off, Input Frequency : 50Hz +/-3%, Power Factor : >0.95, Usage Hours: 12 Hours, LED Drive Current : ≤ 700Ma, Driver Efficiency- : >85%, IEC Compliance : Confirming to IEC-61347-1 & IEC 61347-2-13, IEC 61547,610-3-2,CISPR-15, Control Gear : Integral Design (Tested & Certified for Performance & Safety mandatory from Government approved lab), Driver : Drivers should be constant current constant voltage drivers with separate compartment and active power factor correction topology to ensure optimum driving of LED, also driver compartment should be IP66. Driver should also have Surge, Double phase protection, no load, open circuit and short circuit protection. LED driver should have SELV compliance for safe operation and maintenance. 1.2 Electrical Specifications ( LED Driver) THD(I) : ≤10%, Humidity : 10% to 90% RH, Working Temp : -10C to +50C, Operating temperature of module should not rise above 30C from ambient temperature.LED Luminaire Specifications Life Expectancy : Equal or more than 50000 burning hrs with Minimum 70% lumen maintenance @ Ta 25C, Color Temp : >5700K ± 300K, Color Rendering Index : ≥70± 2, Lumen/watt : ≥ 100 lm/W of system level, LM79 from third party NABL lab (CPRI/ERDA/UL/MSME), Wattage : ≥ 70W / Min lumen output available from system: ≥7000 lumens, Make of LED Source : High Power LED-CREE/CITIZEN/LUMILEDS, Electrical Connector : Armored 1.5Sq MM cable of 0.3meter should be provided, Surge Protection : ≥ 5KV, Lamp Housing : The body shall be robust,corrision resistant superior in finish & without any cracks or throuh holes,made in a single piece by epoxy powder coated high pressure die cast LM6 aluminum alloy.The luminaries shall be monolithic construction totally enclosed dust tight & water proof. The luminaries shall be class I luminary.Degree of protection shall be IP66 as defined in Appendix A of IS10322(Part-I 1982)with latest amendments, Heat Sink/Dissipation : Integrted with in luminaire & The dimensions of luminaries shall be adequate to permit sufficient heat dissipation through the body itself,so as to prevent abnormal temprature rise inside the lantren & consequential damage to cover & gasket materials,LEDs,lenses & Electronic Driver, Optical System : The optical system will consists of individual PC/PMMA lenses on high power LEDs designed & tested to achieve typical street lighting distribution from the LED lantern. This is to ensure maximum utilisation of light flux on the carriageway and minimum glare on the footpath side of the lantern and also in the direction of vehicular traffic, Covers : Toughned glass. It shall not get discoloured shall not suffer degradation due to heat and ageing. The cover shall preferably be secured with stainless screws.should conform with IP-66 Class, Gasket : A extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV glass cover and the metal housing to exclude the entry of dust, water, insects, etc. When the luminaries are closed, should conform with IP 66 Class. Felt gasket will not be accepted, Junction Temp : <85 C, Luminaire system efficiency : >=100 lumens/watt (supported by Cat .Ref./ Model no. LM79 Test report from third party NABL approved lab), Ingress protection : IP-66, certificates from NABL lab (CPRI/ERDA/UL/MSME) , Manafactures Logo : Manufactures Word Mark/Name Engraved/Embrossing on die cast housing to allow tracibility/authenticity till life of fixture(Stickering/Printing not allowed)
90 Watt LED make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves,Havells,Osram) - specifications- 1.1. Electrical Specifications ( LED Driver)-Input Voltage: AC 140 to 270 V AC with Auto resetting Safety Cut-off, Input Frequency : 50Hz +/-3%, Power Factor : >0.95, Usage Hours: 12 Hours, LED Drive Current : ≤ 700Ma, Driver Efficiency- : >85%, IEC Compliance : Confirming to IEC-61347-1 & IEC 61347-2-13, IEC 61547,610-3-2,CISPR-15, Control Gear : Integral Design (Tested & Certified for Performance & Safety mandatory from Government approved lab), Driver : Drivers should be constant current constant voltage drivers with separate compartment and active power factor correction topology to ensure optimum driving of LED, also driver compartment should be IP66. Driver should also have Surge, Double phase protection, no load, open circuit and short circuit protection. LED driver should have SELV compliance for safe operation and maintenance. 1.2 Electrical Specifications ( LED Driver) THD(I) : ≤10%, Humidity : 10% to 90% RH, Working Temp : -10C to +50C, Operating temperature of module should not rise above 30C from ambient temperature.LED Luminaire Specifications Life Expectancy : Equal or more than 50000 burning hrs with Minimum 70% lumen maintenance @ Ta 25C, Color Temp : >5700K ± 300K, Color Rendering Index : ≥70± 2, Lumen/watt : ≥ 100 lm/W of system level, LM79 from third party NABL lab (CPRI/ERDA/UL/MSME), Wattage : ≥ 70W / Min lumen output available from system: ≥9000 lumens, Make of LED Source : High Power LED-CREE/CITIZEN/LUMILEDS, Electrical Connector : Armored 1.5Sq MM cable of 0.3meter should be provided, Surge Protection : ≥ 5KV, Lamp Housing : The body shall be robust,corrision resistant superior in finish & without any cracks or throuh holes,made in a single piece by epoxy powder coated high pressure die cast LM6 aluminum alloy.The luminaries shall be monolithic construction totally enclosed dust tight & water proof. The luminaries shall be class I luminary.Degree of protection shall be IP66 as defined in Appendix A of IS10322(Part-I 1982)with latest amendments, Heat Sink/Dissipation : Integrted with in luminaire & The dimensions of luminaries shall be adequate to permit sufficient heat dissipation through the body itself,so as to prevent abnormal temprature rise inside the lantren & consequential damage to cover & gasket materials,LEDs,lenses & Electronic Driver, Optical System : The optical system will consists of individual PC/PMMA lenses on high power LEDs designed & tested to achieve typical street lighting distribution from the LED lantern. This is to ensure maximum utilisation of light flux on the carriageway and minimum glare on the footpath side of the lantern and also in the direction of vehicular traffic, Covers : Toughned glass. It shall not get discoloured shall not suffer degradation due to heat and ageing. The cover shall preferably be secured with stainless screws.should conform with IP-66 Class, Gasket : A extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV glass cover and the metal housing to exclude the entry of dust, water, insects, etc. When the luminaries are closed, should conform with IP 66 Class. Felt gasket will not be accepted, Junction Temp : <85 C, Luminaire system efficiency : >=100 lumens/watt (supported by Cat .Ref./ Model no. LM79 Test report from third party NABL approved lab), Ingress protection : IP-66, certificates from NABL lab (CPRI/ERDA/UL/MSME) , Manafactures Logo : Manufactures Word Mark/Name Engraved/Embrossing on die cast housing to allow tracibility/authenticity till life of fixture(Stickering/Printing not allowed)
Supply only LED driver for cat Ref. SEL UL 70 W IP66 LXN - Make - Surya
Supply only LED driver for cat Ref. SEL UL 36 W IP66 LXN - Make - Surya
Supply only LED Batten 15 watt(aluminium Base) - make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves , Havells,Osram)
Supply only LED Batten 20 watt(aluminium Base) - make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves , Havells,Osram)
Supply only LED Bulb 15 watt - make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves , Havells,Osram)
Supply only LED Bulb 17 watt - make (Philips,Bajaj,Wipro,Surya,Crompton & Greaves , Havells,Osram)
maharaj ji traders
Katsons Technologies Private Limited
ANAND SERVICES
SHARP TRADING CORPORATION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .