Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.8 L+₹1.5 L (5.26%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected as registered/ notarised MoU between contractor and OEM not uploaded/ submiteed. |
Tender Value
₹28.4 L
EMD Value
₹56,860
Closing Date
14 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
REPAIR AND MAINTENANCE OF PASSENGER/GOODS LIFT AT WECROS BUILDINGS AT NAVAL DOCKYARD VISAKHAPTNAM UNDER GE(I) (DM) VISAKHAPATNAM
2023_MES_615548_1
8852/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM, Visakhapatnam
₹56,860
Yes
19 Oct 2023
24 Aug 2023
21 Sept 2023
24 Aug 2023
14 Sept 2023
31 Aug 2023
Amount
NOTE(for item no 1 to 4) : (a) The comprehensive maintenance work of lifts shall be carried out by OEM only. It is an express condition of the contract that, tenderers shall upload the MoU between contractor & OEM at the time of submission of technical bid in this regard duly signed by all concerened. The documents of MoU between contractor & OEM shall be Registered/Notarised and the same will be produced by the lowest tendered in original within a week from the date of evaluation of financial bids. (b) The maintenance records for maintenance schedule will be maintained by the contractor. Preventive maintenenac consists of carrying out routine check by skilled personnel as specified in particular specification and as recommnedned by OEM. (c) The contractor shall maintain lift in good working conditions without breakdown. The contractor is advised to maintain the rigourous maintenance schedule to avoid any breakdown and send the maintenance personnel regularly and also store the spare parts (Spare parts should be as per OEM's specifications) so that any breakdown can be attended promptly without any loss of time.
(d) The comprehensive maintenance schedule rate includes all the spare parts/ defective equipments and lubrication to all moving parts, topping up of oils as per the lubrication chart including consumable which are required for satisfactory maintenance of the Lift as per specification of OEM, The contractor shall not be paid anything extra for these parts/ equipments and contractor shall also bear the costs of all the defects arising during the period. (e) The contractor shall Service the lifts at regular intervals and as frequently as the OEM directed based on the nature and condition of the lifts, The lift should be maintain in safe and proper working condition. All parts of the lift shall be checked, cleaned and lubricated to keep them both mechanically and electrically in perfect working condition. (f) Renewal all wire ropes and chains (Where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cable and hoistway and machine room elevator wiring. If replacement of main hoist steel rope / trailing cable is required at any time as per recommendation of OEM, the same shall be done by contractor and only cost of hoist steel rope / trailing cable shall only be paid seperately as supply only rate under respective items in this schedule. (g) Replacement of the gear and motor bearing whenever requires as per recommendtion of OEM, cost of the same is included in the rate of Comprehensive maintenance.
(vii) Complaint/ breakdown will be attended/ rectified within 02 to 03 hours after informing the complaint by JE/ AGE E&M or maximum upto 24 hrs after informing/ registering.The contractor shall generally be liable for 24 hours call back services but strictly ensure availability of his responsible representative round the clock daily during the entire period of the contract for attending all types of complaints. They shall promptly attend and call back shall not be kept pending for more than 4 hours (unless it has the prior written approval of the Garrison Engineer). The contractor shall obtain signature of authorized representative of the GE at MES office in token of satisfactory completion of defects. The minor defects shall be made good by the contractor within and including 24 hours time and for major defects shall be made good by the contractor within and including 72 hours time failing which flat rate recovery of Rs 2000.00 per day per lift shall be made from the contractor. In case of minor defects relaxation period for repairs is 24 hrs. However beyond 24 hrs and upto 36 hrs rate of recovery shall be half the rate of Rs 2000/-. In case of major defects relaxation period for repair is 72 hrs. However beyond 72 hrs and upto 84 hrs rate of recovery shall be half of Rs 2000/- and beyond 36 hrs for minor defect and 84 hrs for major defects full recovery @ Rs 2000/- shall be made from contractor. This provision of recoveries shall continue till the lift is completely made functional. per day per lift will be recovered from the contractor's dues."
(viii) Breakdown maintenance consists of :- (a) Attending the fault that may occure and carryout necessary repairs to and replacement of Relys, contactor, Addon block, LED segment, sill plate, minor electronics component and spares etc included in the comprehensive maintenance for item no 01 to 05. electrical and control circuit and mechanical components of the all lifts that may occure during the operation. (ix) It is specifically brought out that this maintenance includes repair/replacement of each and every part of the lift except the replacement of the following items:- (a) V V V F drive (b) IR sensor (c) Inverter (d) Cabin operating panel (e) Door drive unit (f) Drive control panel (g) Governor complete set (h) PLC and deflector pulley set (j) Travelling cable. (k) Trailing cable (l) Converter card of automatic rescue device (m) Mosfet card (n) Maintenance free sealed battery (o) Shaft information system (p) Door motor (q) Micro processor based controller (r) Cost of all other parts which are not mentiond under note no (ix) (a) to (q) or in this schedule but required as per recommendation of OEM for smooth & safe functioning of lifts is included in the quoted rates. (x) The quoted rates against these items shall also include artificial load testing of each lift twice in the total contract period .The rtificial load testing shall be carried out at an interval of not more than six monts. Artificial load shall be arrange by department. Handling and transporting of artifical load from the store yard to work site shall be arrange by contractor].
Supply only main controller transformer primary 415 VAC secondary -24/110/130/230/270 VAC 500V. Make : SSMP
Supply only BRAKE COIL 110 VDC / 230/270 VDC Make : ELECON
Supply only Retiring Cam working on 120 VDC. Make : IES
Supply only illuminated push button working on 12/24 VDC Make : IES
Supply only main contactor with coil, 60 Amps , Power contactor with 2 Nos + 2NC aux. Contacts and with 230 V DC Coil. Make : C&S/AB / TELEMECANIQUE
Supply only auxiliary contactor. 04 Nos + 4NC with 230 V AC Coil. Make : C&S/AB/TELEMECANIQUE / L & T.
Supply only break, protective device to lock / doors mechanically. Make : IES
Supply only Axial Flow Cabin Fan
Supply only Gate lock for collapsible gate complete all as specified and directed.
Supply only main hoist rope of size 13mm heavy duty conforming to relevant IS. Make : USHA MARTIN
Supply only power contactor, 32 Amps with 02 Nos + 2 NC. Aux contacts with 230 V AC/110V DC. Make : SIEMENS / TELEMECANIQUE / L & T/C&S/AB
Supply only 3 change over 24 volts DC relay. Make : PLA/OEN
Supply only 2 change over relay with 12/24 volts DC coil. Make : PLA / OEN
Supply only Gear oil Servo 320
Supply only digital car position indicator BCD logic board. Make : IES.
Supply only Al. Sill for collapsible gate of opening upto 1800mm. Make : IES.
Supply and fix ARD converter with 72 Volts DC to 24 Volts DC Input / output complete all as specified and directed. Make : Jeltron or equivalent as approved by GE.
Supply and fix MOSFET card with 72Volts AC to 230Volts AC complete all as specified and as directed. Make : JELTRON / IES
Supply only power contractor 32 Amps with 24/48 V DC coil. Make : Siemens/Telemequenices
Supply only trailing cable 10 core x 0.50 Sqmm Make : BST / GG / Rolliflex
Supply only infrared sensor for car door including transmitter, receiver, and control unit working on 230VAC. Make : Cedes / TL Jones
Supply only variable voltage variable frequency drive suitable for lift including setting of all parameters to suit the controller with full load complete after taking down old unserviceable one complete all as specified and as directed. Make: Toshiba / Yasakawa / Control Tech / EMERSON
Supply only break unit complete for machine unit of lift.
Supply only door motor with built in rotary encoder, VVVF drive for car door operator complete all as specified and as directed. Make: TOSHIBA / MONARCH
M&L for taking down unserviceable / burnt main motor 3 phase, 415V, 10 to 15 HP, 1450 RPM and rewinding the same using copper wire of suitable gauge and all insulation, varinishing, drying and refixing of the same in position after testing complete including replacement of necessary nuts and bolts for foundation, etc., complete all as per manufacturers instructions and as directed.
Supply and fix speed reduction gear box suitable for elevator with phosphorus bronze worm wheel and stainless steel worm shaft housed in cast iron housing with suitable bearings for worm wheel and worm shaft. The gear box shall be oil cooled with glass inspection window to inspect the oil level in the gear box. The gear box shall be provided with necessary eye bolt for handling the gear box for transportation and erection. The shaft shall be provided with necessary key to lock the flange properly complete all as specified and as directed. Make : ELECON / MONTANARI / SHANTI
Supply and fix 3 phase induction motor up to capacity 5.5KW suitable for elevator and VVVF drive working on 400VAC supply, 50Hz frequency, 4 Pole, S4 class duty 40%, flange mounting with 'F' Class insulation. The shall have double shaft extension for fixing coupling flange on one end and on other end to fix fly wheel, both the shaft end shall be provided with locking key to fix flange and fly wheel properly. Shaft dia shall be not less than 55mm, thermistor for over heat protection shall be provided with IP21 protection complete all as specified and as directed. Make : MONTANRI / SIEMENS / BHARAT BIJLEE
Supply and fix dual shaft extended brake unit working on 110 VDC supply, the brake unit shall have 2 coils with emergency release handle along with drum and arms with brake bands of 6mm thickness complete all as specified and as directed. Make : MONTANRI / IES
Supply and fix Mild steel frame suitable for mounting elevator gearbox along with traction sheave, motor, break unit and other components of machine unit of elevator, the frame shall be provided with anti vibration rubber pads along with all hardware required to fix the complete machine unit, the frame shall be made out of suitable 'C' channel and 'I' beam complete all as specified and as directed. Make : IES
Supply and fix cast iron heat treated traction sheave suitable for 13mm elevator steel rope along with locking key to mount on gear box the sheave shall be of 520mm dia with 4 grooves for rope complete all as specified and as directed. Make : MONTANRI / IES
Supply and fix car door operator complete including 0.5 KW PM Motor, VVVF drive suitable for PM motor, Al.skate, Al. sill and all necessary hardware complete all as specified and as directed. Make : FERMATOR / IES
Supply and fix shaft information system working on 24VDC magnetic type with fixing brackets, magnets and all necessary fixing hardware complete all as specified and directed.
Supply and fix Car operating panel suitable for Auto Door / Goods Lift serving up to 7 floors with illuminated push button working on 24 VDC and digital position indicator with travel direction indicator working on 24VDC. All shall be mounted on 1.5mm thick stainless steel 304 grade sheet with acrylic sheet for digital position indicator. All necessary hardware shall be provided to fix the COP at site complete all as specified and as directed.
Supply and fix Landing Door Mechanism suitable for Centre Opening Auto door 800mm along with SS Panels with Vision Panel complete all as specified and as directed.
Automatic Rescue Device unit complete for Manual / Auto operated door, Goods / Passenger lift of capacity 2000K/3000 Kg with main motor up to 11 KW Motor with VVVF for Power Control, battery backup of 72 V shall be provided with battery charging unit / circuit. Inverter circuits with Transformer for break door control shall be incorporated. All indications like battery charging, Rescue Operation ON, Lift moving up, Lift moving down, Safety Complete, Lift at floor shall be on the front panel, battery 12 V 7.2 AH-07 No's. All necessary power and control wiring kit between existing controller and ARD shall be provided along with shaft information system for the lift direction including suitable capacity battery for backup system complete all as specified and as directed. Make : IES / JELTRON
Supply and fix Microcontroller based processor control for AR Device working on 24Volts DC with 24 Volt input / output complete all as directed. Make : IES
Supply only landing push button with display box complete all as specified and as directed. Make : IES
Supply and fix 12 relay card suitable Automatic Rescue Device, Relay shall be 1 C/O with 24 VDC coil, 6Amps current rating contacts, each relay shall be provided with LED indicator and Varistor for protection on output side. Plug in connectors shall be provided on Input and Output side complete all as specified and as directed. Make JELTRON / IES
Supply only 12 volts 7 AH maintenance free sealed battery complete all as specified and as directed. Make: Exide/Amco
Supply and fix micro processor micro logix 1200 (40 I/O) programmable type 1762-L40BWA, input power 230Volts AC +/- 15% at 47 to 63Hz power supply usage 82VA, output voltage 24 V DC at 400MA. Input :- Input circuit type 24V DC sink / source, on state voltage range 10 to 24V DC, OFF State voltage 0 to 5VDC, Input impedance 2.7 K Ohm. Output :- Output type relays, current per group of 4 relays 8 Amps, Turn ON/OFF times 10 millisecond, relay contact rating 24Volt DC 2.0 Amps for full collective operation to match existing auto door lift including software installation and necessary relays and contactors complete all as specified and directed. Make : Allen Bradley
S&F Microcontroller based processor control for ARD working on 24 V DC,plug type connectors on input and out put side ,output side shall have 2 connectors one for relay bd and other one for status indicator on ARD door including all input shall be protected by opt couplers all as specified and directed. Make:- JELTRON /IES
S&F false ceiling made out of 1.2mm MS with powder coated finish incl fan grill and 4 Nos 5 Watt LED down light .Incl taking down the old false ceiling complete all as specified and directed. Make:- IES
Material and labour for replacement of collapsible gate assembly including roller wheels, wheel track (bottom and top) of existing size at site for any floor / wall including replacement of unserviceable rubber bushes, grill, handles and greasing complete all as specified and directed.
Material and labour for preparation of old painted surface of passenger/ Goods lift cabin car including door/ collapsible gate at all floors, control panel, motors, gearbox, counter weights and other steel surfaces and applying one coat of synthetic enamel paint of shade same as existing all as specified and directed.
Supply and fix , cabin top for 2000 Kgs Goods lift with all necessary cut outs made out of 2mm thick MS sheet and false ceiling made out of SS sheed including new down lights & cabin fan after taking down old U/S MS cabin top complete all as specified and directed.
Supply and fix Cabin panels of all 2 sides of lift made out of stainless steel sheet of 1.5mm suitable for 10 Passenger lift including taking down old U/S MS cabin panel complete all as specified and directed.
Supply and fix Cabin panels of all back and front sides of lift made out of stainless steel sheet of 1.5mm suitable for 10 Passenger lift including taking down old U/S MS cabin panel complete all as specified and directed.
Supply and fix , Cabin Cabin bottom for 10 Passenger lift made out of MS Chanel with 19mm plywood on top and 1.5mm PVC vinyl flooring including all necessary fixtures for fixing on existing car sling with hardware including taking down old U/S MS cabin bottom complete all as specified and directed.
Supply and fix , cabin top for 10 Passenger lift Goods lift with all necessary cut outs made out of 2mm thick MS sheet and false ceiling made out of SS sheed including new down lights & cabin fan after taking down old U/S MS cabin Top complete all as specified and directed.
SANTOSH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .