Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.7 L+₹1.5 L (7.81%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.6 L+₹2.4 L (12.8%)Rejected-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.4 L+₹4.2 L (21.8%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.5 L+₹4.3 L (22.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹29.1 L
EMD Value
₹58,240
Closing Date
2 Aug 2023, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
Special Repair to internal electrifications including light fittings and fixtures in certain OMQs and SMQs at AF Stn Jodhpur and Special Repair Replacement of building earthing in SMQ at AF Stn Jodhpur
2023_MES_607929_1
8403/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (AF) No 02 Jodhpur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹58,240
Yes
5 Sept 2023
4 Jul 2023
4 Aug 2023
4 Jul 2023
2 Aug 2023
19 Jul 2023
4 Jul 2023 - 12 Jul 2023
Amount
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonry walls, with or without reinforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by Engr-in-charge. Note : Rate of PVC Conduit included in relevant point wiring and shall not be paid separately.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly, drawn in surface/concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relevant item.
One light / fan point controlled by one switch one way.
One light point controlled by two Nos 5 Amps switch two way
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independent board.
One bell point controlled by one switch 5 Amps bell push.
All as per item ser No 3.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independent board.
All same as per item ser No 3.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole two way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F Bell Push modular single pole one way 6 Amps 230 volt 1 module.
S&F Stepped type modular electronic fan regulator, socket size, flush type 230V AC.
S&F Ceiling rose surface bakelite 65x50mm three terminal.
S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or square box using necessary screw & gutti complete all as specified.
S&F electronic Bell Bul-Bul music, 230 volt, single phase.
Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unscrewing from position, dismantling blades, stacking carefully at site for reuse of serviceable fans complete all as directed and specified.
Taking down carefully Electric geysers by disconnecting electrical connections, stacking carefully at site for reuse of serviceable Geysers or deposit to E/M store if new geyser provided against replacement all as directed and specified.
Taking down carefully Energy meters by disconnecting electrical connections, stacking carefully at site for reuse of serviceable meters or deposit to E/M store if new meter provided against replacement all as directed and specified.
Fixing only light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note : Serviceable light fittings taken down against item No 01 shall be used at site as directed by Engr-in-charge.
Supply and fixing in repair LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, correlated colour should be minimum 6000 degree kelvin complete all as specified and directed.
Supply and fixing in repair LED light fitting wall /roof mounted, Aluminium housing, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distortion (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, correlated colour should be minimum 6000 degree kelvin complete all as specified and directed.
S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, including suitable bracket for fixing light on wall or any indicated location all as specified and as directed by Engr - in Charge. Make : Havells Cat No: ENDURAPEARLSL25W or equivalent model/Make approved makes.
S&F in repair LED light fitting 1 x 10W bulkhead luminaires including in build LED light driver perfect interior and exterior application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
NOTES FOR LED LIGHT FITTINGS & BULBS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
M&L for cutting holes 300mm diameter for preparing opening through wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge.
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Fan taken down against item No 16.00 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleaning of dust etc.)
Fixing only exhaust fan 300mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Exhaust Fan/wall fans taken down against item No 16.00 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleaning of dust etc.)
Fixing only and connecting electric meters upto 100 amps with necessary incoming and outgoing copper cable using suitable size copper alloy thimbles/lugs and numbering of connected married accommodation number all as specified and directed. Note : Serviceable meter taken down against item No 18.00 shall be used for re-fixing.
Installation only Electric Storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & Nuts, gutties etc., complete all as specified and directed. NOTE: Taken down serviceable geyser against item No 17.00 shall be used after cleaning and necessary repairs.
S&F Exhaust fan 300 mm sweep, copper wounded, four blade, metal body, BEE approved/ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.) including taking down old unserviceable sub-main wiring complete all as specified for Two runs of 2.5 Sq.mm main Phase-Neutrals supply cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire in green colour (for servant qtr supply).
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.,) including taking down old unserviceable sub-main wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green colour. (for SMQ)
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.,) including taking down old unserviceable sub-main wiring complete all as specified for Four runs of 6.0 Sq.mm main R-Y-B-N supply cable alongwith two run of single core 6.0 Sq.mm for continuous earth wire in green colour. (for OMQ)
S&F sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 16 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested complete including taking out old all as directed.
S&F sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested complete including taking out old all as directed.
S&F sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested complete including taking out old all as directed.
M&L for MCB TPN/FP, 63 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 6 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof bakelite/hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incoming and outgoing control MCCB/MCBs, each meter compartment shall provide with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated Sameness grey paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 160 Amps, 4 pole as incommer and vertical or horizontal copper busbar chamber for taking connection to incommer MCB of each meter by using 10 Sqmm, PVC insulated multi-stranded copper conduction wire single core in proper colour codes all as specified and items accommodated as under :- (a) MCCB 160 Ams, 4 pole, 16 kA, (Ics=100 % of Icu) - as incommer (b) Copper Busbar 200 Amps duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set (c) 2 runs of PVC insulated single core multi-stranded FRLS grade copper wire for connection from bus bar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles. (d) MCB SPN 63 Amps on each meter incomming pre-wired - 6 Nos ( One incomming each meter) (e) MCB SPN 40 Amps on each meter outgoing pre-wired - 6 Nos (One outgoing on each meter) (f) LED Indicator lamp (R,Y,B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter panel on wall surface and re-fixing energy meter inside panel, making all incoming and outgoing electrical connections with existing input cable and outgoing wires.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antenna on roof of building complete all as specified. Note : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deems to be included in quoted rates.
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of width all-around of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly reinforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Supply and laying GI Pipe 15 mm dia, light grade for protection of GI Earth wire 4.0mm dia complete all as specified & directed. Note : Quoted rate deems to be include cost of GI Saddle used for fixing GI pipe on wall by using screw and guttis not exceeding distance 0.6mtr.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0mm dia galvanised iron or steel wire all as specified.
RISING ELECTRICALS
new india engineers
Shri Electrical Enterprises
J AND T Enterprises
Siddharth Constructions
M/S BUDHRAM BISHNOI
GINTASH ENGINEERS AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .