Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹34.4 L+₹1.6 L (4.99%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹34.9 L+₹2.2 L (6.57%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹39.7 L+₹6.9 L (21.1%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹40.1 L+₹7.3 L (22.3%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Jan 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FOR OPERATION AND MAINTENANCE OF HT/LT INSTALLATIONS AND UPKEEPING OF INTERNAL ELECTRIFICATION IN RESIDENTIAL AREA AT SERVICE CENTRE NO 2 AT DRDO COMPLEX CV RAMAN NAGAR UNDER GE(I) RndD (WEST) BEGALURU
2019_MES_306302_1
GE(I) R ND D (WEST)/BAN/65 OF 2019-20 8783E8
Open Tender
Manpower Supply
Item Rate
335 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹80,000
Yes
31 Mar 2020
17 Dec 2019
14 Jan 2020
18 Dec 2019
8 Jan 2020
2 Jan 2020
18 Dec 2019 - 1 Jan 2020
Amount
Providing services for maintenance, operation and up-keeping of HT & LT installations, switch gears, RMU/SF6 / load break units, power controlled, transformers, OCBs and VCBs, OH lines 4 pole structures, GODs, DO fuses, street lights controls, LT panel boards, DG sets, installed in Sub-station No 2 (Service Centre 2), including fuse off call and maintain the equipments as detailed here-in-after and as directed by Engineer - in - Charge. The quoted rate shall deemed to include for the following :- NOTES for Serial Item Nos 1.00 :- i) Manning and Operating round the clock in three shifts on all days including Sundays and Holidays . (0600 Hours to 1400 Hours - Ist Shift, 1400 Hours to 2200 Hours - 2nd shift & 2200 Hours to 0600 Hours - 3rd shift) with Electrician - 1 No and Helper - 1 No per shift . All the above tasks shall be performed by skilled persons possessing the requisite qualifications. Contractor has to produce such certificate issued by the Government authorities to the Garrison Engineer for approval before commencement of work. ii) Cleaning of working areas, equipments, sub stations building and maintenance of garden areas. iii) Proper records of all operating parameters in the prescribed log book/register shall be maintained by the contractor in the installation for periodical check by the Engineer-in-charge. iv) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF and ESI paid against the respective workmen while claiming payments.
Sl Item No 1.00 (contd.,) v) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from the payment due . The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. vi) Tenderer shall arrange insurance to his work-men and relevant proof of the same shall be submitted to the department as and when demanded, cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. Provisions of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF and ESI paid against the respective workmen while claiming payments. vii) Various items required for replacement shall be regulated by the department specified as 'supply only' items here-in-after. However, replacement cost (labour element) of those items shall deemed to be included in the quoted rate of this item. Items mentioned as 'Supply only', shall be supplied by the contractor as per site requirement. viii) The rates quoted by the Contractor / firm shall not be less than minimum wages as notified by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable. In case the rates quoted are less than the minimum wages as mentioned hereinbefore, his/their tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only. Contractor shall not have any claim in this regards.
Periodical checking and attending day to day E/M complaints, connected with internal electrification and maintenance of internal electrification comprising of periodical checking of power DBs including tightening of connections, changing of burnt-out terminals, MCBs, connectors etc., checking of earthing of the LT distribution system, periodical maintenance of earth pits including measurement of earth resistance, attending day-to-day complaints including checking and replacement of burnt-out and unserviceable items like wiring, connected fittings and fixtures, MCB DBs, ceiling fans, exhaust fans, replacement of tube rods of any wattage, choke, starters, point wiring, sub-main wiring, switch socket combination of any capacity, switches, fan regulators, capacitors, replacement of fuses, CFL bulbs, lamp holders etc., complete all as specified, in day time by deploying certified / skilled workers in general shift service center No. 2 and in fuse off call office, on all days including Sundays and holidays, complete all as specified and directed. NOTES for Serial Item Nos 2.00 :- i) Manning and Operating in one shift on all days including Sundays and Holidays (0830 Hours to 1730 Hours with Electrician - 1 No and Helper - 1 No per shift. All the above tasks shall be performed by skilled p persons possessing the requisite qualifications. Contractor has to produce such certificate issued by the Government authorities to the Garrison Engineer for approval before commencement of work. ii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of payment of wages, EPF and ESI against the respective workmen while claiming payments,
Sl Item No 2.00 (contd.,) iii) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from payment due. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. iv) Various items required for replacement shall be regulated by the department mentioned as 'Supply only' items here-in-after. However, replacement cost (labour element) of these items shall deemed to be included in the quoted rate of this item. These 'Supply only' items shall be supplied by the contractor as per site requirement. v) Also refer Schedule 'A' Notes for further provisions forming part of the quoted rate. vi) The rates quoted by the Contractor / firm shall not be less than minimum wages as notified by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable. In case the rates quoted are less than the minimum wages as mentioned hereinbefore, his/their tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only. Contractor shall not have any claim in this regards.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FRLS Grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 4.0 sq.mm size, FRLS Grade, complete all as specified and directed.
Supply only PVC insulated, flexible copper cable, 23/0.0052, 3 core, 230 volts, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one way, complete all as specified and directed.
Supply only calling bell, ding-dong type, 230 V, single phase, complete all as specified and directed.
Supply only bell push, single pole, flush type, 230 V, 5 Amps, complete all as specified and directed.
Supply only fan capacitor of 2.5 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only fan capacitor of 4.0 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only ceiling fan clamps for fixing of ceiling fans with rubber bushings, complete all as specified and directed.
Supply only 18 W, LED tube light, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, complete all as specified and as directed.
Supply only LED down lighter fitting with high lumen output, environmental friendly, energy efficient LED, light fitting with lamps and accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, down lighter 2'x2' along with fixture, 42 W cat No VENUSNEOHE 2x2PLR 18-42 LED865MOD with driver (2'x2') of Havells or techno-commercially equivalent specified here-in-after.
Supply only MCB, SP, 230 V, 6 to 32 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB SPN, 230 V, 6 to 40 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB TPN, 415 V, 63 A current rating, 'C' series, 10 KA breaking capacity complete all as specified and directed.
Supply only MCB TP, 415 V, 100 Amps current rating, 'C' series, 10 KA breaking capacity , complete all as specified and directed.
Supply only PVC casing/capping of 20mm size, complete all as specified and directed.
Supply only PVC casing/capping of 25 mm size, complete all as specified and directed.
Supply only fan regulator electronic type, 230 V, stepped type, 200 W complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 5 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 15 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only LED bulb 9/11 Watt.
Supply only Angle holder complete all as specified and directed.
Supply only, 20/22 W, decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient LED, tube light fitting with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.LUMILINEPLUSBS22WLED865SPCSS of Havells or techno-commercially equivalent specified here-in-after.
All as per SI item No 26.00 but of capacity 9/10 Watt complete all as per Make : Havells Cat No :LUMILINE BS 9W LED 865SPCWH or equivalent specified here-in-after.
Supply only LED street light along with fixture, 60W, IP 65, with high lumen output, environmental friendly, energy efficient LED, street light fitting with lamps and accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, Cat No ENDURAPEARLPLUS SL60WLED757PASYTOPC of make Havells or techno-commercially equivalent specified here-in-after.
Supply only heating coil of 1000 / 1500 / 2000 W capacity geysers complete all as specified and as directed.
Supply only thermostatic switch for any capacity of geysers complete all as specified and as directed.
Supply only PVC connection pipe 15 / 20 mm dia, 450 mm long with coupler & washer on both sides, complete all as directed.
Supply only Four pole MCCB, 100 Amps, 16 kA, thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
Supply only MCCB TPN 200 Amps working on 440 volt, 50 Hz AC supply, 25 KA, SKB2 series complete all as specified and as directed.
Supply only MCCB TPN 250 Amps working on 440 volt, 50 Hz AC supply, 25 KA, SKB2 series complete all as specified and as directed.
Supply only modular switch one way 6 Amps one module.
Supply only modular bell push one way 6 Amps 2/3 pin 2 module.
Supply only modular socket one way 6 Amps one module.
Supply only modular switch one way 16 Amps Combined.
Supply only modular socket 6A/ 16A-2/3 Pin. NOTEs for Sl. Item No. 3.00 to 39.00 (a) These items shall be supplied by the contractor as per requirement at site (b) It must be ensured by the contractor that 10% of above items shall be made available at any point of time for day-to-day maintenance during contract period.
H S S ENGINEERS AND CONTRACTORS
M/S Sneha Enterprises
Arunachaleswara enterprises
Sahara Engineers
Solar Electricals and Electronics
UNIVERSAL ENGINEERING
M/S SRI BALAJI ENTERPRISES
Lucky Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .