Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 LAccepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | 1 | Accepted-AOC LOWEST ACCEPTED | |
| 2 | 2₹3.2 L+₹46,674 (16.9%)Rejected-AOC VENGARA LAC SL NO 2412 KOTTAPPARAMBU AREEKKULAM ROAD | IDUKKI | KERALA | 685533 | 2 | Rejected-AOC REJECTED | |
| 3 | 3₹3.4 L+₹59,613 (21.6%)Rejected-AOC | 3 | Rejected-AOC REJECTED | |
| 4 | 4₹3.5 L+₹74,968 (27.2%)Rejected-AOC | 4 | Rejected-AOC REJECTED | |
| 5 | 5₹6.3 L+₹3.6 L (129.7%)Rejected-AOC 676301 | MALAPPURAM | KERALA | 676301 | 5 | Rejected-AOC REJECTED |
Tender Value
₹4.4 L
EMD Value
₹8,932
Closing Date
26 Jun 2023, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Secretary Nannambra Grama panchayat
Secretary Nannambra Grama panchayat
WARD 7,8,19 INSTALLATION OF MINIMAST LIGHT
2023_DP_581362_1
A2-6252/23
Open Tender
Electrical Works
Item Rate
NANNAMBRA PANCHAYAT
Please refer Tender documents.
5 documents required · 5 mandatory
₹932
₹8,932
3 Feb 2024
12 Jun 2023
29 Jun 2023
12 Jun 2023
26 Jun 2023
12 Jun 2023
Amount
Electrification
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD9687/2023-2024:Supply Conveyance, installation, testing and commissioning of g 25A, 2Pole, AC 1 rated power contactor with 1NO+1NC auxiliary contacts & with AC coil
OD9690/2023-2024:Supply Conveyance, installation, testing and commissioning of 24 Hours Analog Timer for operating automatic ON-OFF function
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.1.1.2:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD9691/2023-2024:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD9692/2023-2024:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD9693/2023-2024:Supplying and Providing and fixing 25 mm X 3mm G.I. strip earth lead from the test joint to the earth plate
OD9694/2023-2024:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthling system
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD9703/2023-2024:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc
OD9704/2023-2024:Providing and fixing Notice plate of 500 mm X 400 mm, made of mild steel, at least 6 mm thick, and vitreous enameled white on both sides, and with inscription on front side as required as per the instruction.
OD10225/2023-2024:Supply and installation of dust and vermin proof sintex box ( MB 3425) and to fix kseb meters, fuse unit, CTs, etc as required , including fixing it on existing concrete pillar. Giving connection as required
OD10226/2023-2024:Supply and installation of dust and vermin proof sintex box (3425) and to fix MCB and isolator etc. as required , including fixing it on existing concrete pillar. Giving connection as required.
OD10258/2023-2024:Supply,Conveyance and fixing the following size of GI pipe along with painting 2 coats of synthetic enamel paint over a coat of synthetic enamal paint over a coat of zinc chromate primer etc as required 40 mm dia GI pipe (medium class )
OD9706/2023-2024:Charges for preparation of KSEB test Report for submitting to the concerned KSEB section office
M POWER TRADING SYSTEM
SAJITHLAL K
AJITH
AK ELECTRICALS
Bidder Name
AJITH
SAJITHLAL K
AK ELECTRICALS
M POWER TRADING SYSTEM
ELEKTRA ENGINEERING
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .