Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NIL | NA | NA | 121004 | Admitted-Finance |
| 2 | Admitted-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
13 Mar 2021, 6:00 pmClosed
GE (N) Tezpur
GE (N) Tezpur co 99 APO
REPAIRS/MAINT/SERVICING OF DG SETS, VOLTAGE STABILIZERS INCLUDING REPLACEMENT OF UNSERVICEABLE SPARES AND OTHER CONNECTED ITEMS AT NAA UNDER GE (N) TEZPUR
2021_MES_421920_1
GE(N)/TEZ/2020-21/8458
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Tezpur
As per tender docus
8 documents required · 8 mandatory
₹500
GE (N) Tezpur
₹24,000
Yes
16 Mar 2021
13 Feb 2021
15 Mar 2021
13 Feb 2021
13 Mar 2021
27 Feb 2021
14 Feb 2021 - 21 Feb 2021
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Labour only for carrying out Maintenance of DG set of various capacity as indicated below as directed by Engr- in -charge for the following DG sets of Make:- Kirloskar/Mahindra & Mahindra. Note: (I) Maintenance of DG set to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (II) Materials/Spare parts/Lub oil required for above maintenance shall be measured and paid seperately under repective items as "Supply only Materials".
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Supply only of Lub Oil of specific grade (20W40 or Eqv.) for carrying maintenance under SL No-1 above. Make-Kirloskar/ Servo pride(IOC)/Castrol/Veedol or Equivalent.
Supply only of Premix Coolent of radiater water for carrying maintenance under SL No-1 above.Make Bharat/Greaves or Equivalent
Supply only of Lub Oil filter element with 'O' ring, for carrying maintenance for the DG set of various capacities and make as indicated below:-
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Supply only of Fuel filter element with 'O' ring, for carrying maintenance for the DG set of various capacities as indicated below:-
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set of various capacities as indicated below:-
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Takingdownt worn out and Replacement of Fan Belt for dynamo for the following DG Sets:-
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Taking down and replacement of Radiator Fan Belt of the following DG set.
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Takingout and repair/replacement of Water Pump Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp of following DG Sets:-
100 KVA DG set
62.5 KVA DG set
40 KVA DG Set
30 KVA DG Set
15 KVA DG Set
7.5 KVA DG Set
Supply only for filling of Distilled Water for Batttery.
M&L for takingout and replacement of Indicator lamp for R-Y-B phase.
M&L for Takingout and repalcement of oil presure meter for 30/62.5/100 KVA DG set.
M&L for Taking down and replacement of Water temperature meter (as per sample) for 30/62.5/100 KVA DG Set.
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush for the DG set of capacity 7.5 KVA.
As per item no 14 but for the DG set of capacity 15 KVA.
As per item no 14 but for the DG set of capacity 30/40 KVA.
As per item no 14 but for the DG set of capacity 62.5 KVA.
As per item no 14 but for the DG set of capacity 100 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush etc for the DG set of capacity 100 KVA.
As per item no 19 but for the DG set of capacity 62.5 KVA.
As per item no 19 but for the DG set of capacity 30/40 KVA.
As per item no 19 but for the DG set of capacity 15 KVA.
As per item no 19 but for the DG set of capacity 7.5 KVA.
Takingout burnt/unservieable alternator assembly and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush etc for the DG set of capacity 100 KVA.
As per item no 24 but for the DG set of capacity 62.5 KVA.
As per item no 24 but for the DG set of capacity 30/40 KVA.
As per item no 24 but for the DG set of capacity 15 KVA.
Takingout and replacement of complete self starter of DG set of Various capacity as mentioned below:-
100 KVA DG Set .
62.5 KVA DG Set.
40 KVA DG Set .
30 KVA DG Set .
15 KVA DG Set.
7.5 KVA DG Set.
M&L for fixing the asbestos rope on silencer of DG set of various capacity including cladding with asbestos powder over wire mesh.
M&L for cleaning of the fuel tank by vacating the tank, replacement of fuel level indicator and spray painting of tank by scraping the existing paint using enamel paint of two coat with matching the existing clour.
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 20-125 KVA
M&L for Replacement of Voltage regulator Device (AVR) for the DG set of capacity 20 to 50 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
M&L for Replacement of Voltage regulator Device (AVR) for the DG set of capacity 62 to 100 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
Reparing/Overhauling & calibration FIP with injection of 100 KVA all as specified and directed by EIC and manufacturer instruction.
Reparing/Overhauling & calibration FIP with injection of 62.5 KVA all as specified and directed by EIC and manufacturer instruction.
M&L for Earthing complete with galvanized steel earth electrode 60cm x 60 cm x 6.3 mm buried directly in ground vertically to a depth not less than 3.25 mtr below ground level with the top edge not less than 2.5 mtr below ground level connected to galvanised strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, watering pipe of 40 mm bore GI pipe medium grade, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, desposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and directed. NOTES 1. The unit rate includes for protection GI pipe of 15 mm bore including excavation for earth pit in any type of soil disintegrate rock and refilling of soil after removing stone from soil. and galvanised wire 4.00 mm dia from top of earth plate upto 7.5 meter above ground level.
M&L for fixing of 120 AH,12 Volt lead acid battery of Make: Exide New Express or equivalent.
M&L for fixing of 180 AH,12 Volt lead acid battery of Make: Exide New Express or equivalent.
Supply & Fix manual change over switch system 3 phase ,415 volt , AC , 200 Amp with sheet steel enclouser extended handle all as specified and directed by EIC.
M & L for replacement of voltmeter(LED/Digital) 0-500 volt range as per sample.
M & L for replacement of Ampere meter (LED/Digital) 0-300 amp range as per sample.
Supply and Replacement of battery charger of 12/24 Volt.
MD. LATIFUL AHMED HUSSAIN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .