Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | L1 | Accepted-AOC due to L1 | |
| 2 | L2₹1.2 L+₹1,169.68 (0.96%)Rejected-Finance 15NO KEDLA DIST RAMGARH JHARKHAND | KEDLA | RAMGARH | JHARKHAND | L2 | Rejected-Finance due to L2 | |
| 3 | L3₹1.2 L+₹3,369.68 (2.77%)Rejected-Finance 2ND FLOOR 76A PHUL SARAI RANCHI ROAD DISTT RAMGARH JHARKHAND | RAMGARH | JHARKHAND | L3 | Rejected-Finance due to L3 |
Tender Value
₹1.4 L
EMD Value
₹1,800
Closing Date
21 Oct 2023, 12:00 pmClosed
PE(EnM)
TNOCP
Installation of 100 KVA, 3.3 KV/440 V distribution transformer, erection of one span 440 V OH Line and wiring in pump section room at 42 NO old quarry at Tapin North OCP under Hazaribagh Area
2023_CCL_290863_1
PE(EnM)/TNOCP/Tender/23-24/27
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
TNOCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,800
21 Oct 2024
10 Oct 2023
23 Oct 2023
11 Oct 2023
21 Oct 2023
11 Oct 2023
11 Oct 2023 - 14 Oct 2023
Amount
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 diameter and above including binding etc as reqd.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 diameter and above including binding etc as reqd.
Supply and Erection of stay set complete (Galvanized) with 19/20 mm dia X1.8 m long stay rod, anchor plate of size 45cmX45cmX7.5mm, thimble, stay clap, turn buckle (20 mm x 60 cm), 7/4.00mm dia GI stay wire & strain insulator etc in cement concrete 1:3:6 (1 cement:3coarse sand:6 graded stone aggregate 40 mm nominal size) foundation including excavation & refilling etc as required.
Erection of cradle guard as required.
Erection of angle iron/ channel iron cross arm on wood/RCC/PCC/steel tubular/rail pole etc as required.
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
Earthing with copper earth plate 600mm X600mmX3mm thick including accessories, and providing masonry enclose with cover plate having locking arrangement and watering pipe of 2.7meter long etc with charcoal/ cock and salt as required
Providing and fixing 25 mm x 5 mm G.I strip on surface or in recess for connection etc. as required.
Supplying and drawing of 2 x 4 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of 150 mm X 150 mm X 60 mm deep sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
Supplying and fixing of 5/6 amps switch piano type switch/ socket on the existing switch box/ cover including connections etc. as required.excavation & refilling etc as required.
Supplying and fixing of15/16 amp piano type switch/ socket on the existing switch box/ cover including connections etc.
Supplying and fixing of 3 pin 5/6 amp socket outlet piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
Supplying and fixing of 6 pin 15/16 amp socket outlet piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.together, including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc. and painting with primer and finish paint as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load as required .Single pole and neutral. in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Providing & Fixing concrete earth chamber pit of size 310 X 310 X170 for earth pit as required.
Installation of 100 KVA, 3.3 KV/440 V Transformer
Installation of 11KV grade GOAB Switch
Installation of Horn gap Fuse
Cradle guard making
Installation of Light fitting
Pole painting
Total impact of GST for the purpose of CTC
Auto Power Enterprises
VIDYA ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .