(a) Repairs to veterinary hospital located in HSL Colony premises. (b) Repairs to public library located in S2 and S3 quarters.
2023_HSL_93558_1
OS/CM/001908/000040R
Open Tender
Civil Works
Works
30 days
Hindustan Shipyard Limited
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹6,000
Yes
2 Nov 2023
12 Oct 2023
26 Oct 2023
12 Oct 2023
25 Oct 2023
13 Oct 2023
Repairs to Public Library located in S2 & S3 quarters (part - A, for civil works)
Provide and lay water proofing treatment consisting of: (i) removing the existing damaged top layer of concrete and cleaning of roof slab. (ii) Repairing of all surface cracks wider than 3mm with polymer modified mortar prepared with Sikatop 77 acrylic polymer. (iii) Providing and laying cement plaster in CM 1:6 (where ever required to cover the undulations of slab surface) duly admixed with Sika Plastocrete Super @ 0.2% by weight of cement, over a bond coat of Sika Latex Cement Slurry to make the surface smooth and even at low levels. (iv) Application of priming coat of compatible bituminous primer Sika WP Shield Primer W or Shalikote @ 0.300 kg per sqm over the cleaned and prepared roof surface complete as per satisfaction of the Engineer-in-Charge. (v) Providing and laying STP(Shalimar) or Sika Atactic Polypropylene Polymer (APP) modified five layer prefabricated waterproofing membrane with thermal fusible properties on both side and having minimum thickness of 3.0mm and unit weight not less than 4.0 kg/sqm reinforced with non woven spun bonded polyester reinforcement @ 160 gm / sqm, <-50C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly, leaving no bare edge or end of APP membrane and finishing the surface with trowel or otherwise to obtain a uniform surface. The minimum side lap and end lap shall be kept at 75mm and 100 mm respectively. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane and membrane shall be laid over a coat of bituminous primer @ 0.300 kg./ltr per sqm made by the same membrane manufacture after necessary surface preparatory works such as cleaning the surface thoroughly and shall be finished in all respect as per direction of Engineer-in-Charge. (vi) Applying two coats of aluminium paint over the surface to protect from sun rays etc., complete
Chipping of unsound/weak concrete material from slabs & whereevr required etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and necessary scaffolding rrangements and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles etc., complete all as directed.
Supply and apply the NitoZinc primer of fosroc make to the existing prepared surface of reinforcing bars to protect from corrosion complete all as directed.
Providing building up of isolated damaged portions in ceilings & whereever required using polymer modified cementations mortar with cement sand ratio 1:3 using Nito bond SBR/ approved equivalent at the rate of 7lts/ bag of cement to an minimum thickness of 25 mm to 50 mm over the primed surface usisng Nito bond SBR in 1:1:3 by volume (Nitobond SBR :water: cement). Repair mortar has to be applied before priming coat dries, if the bonding compound dried it should be re- coated and curing the repair mortar after competion of repair work with Nito bond AR (1 part of water by volume) as a curing membarance at a coverage of 8-10 Sq.m / lit cost including scaffolding & staging work up to 5 M height and wherever necessary, all complete as specified and directed by the engineer in charge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level in all shapes and sizes in cement mortar (1:4) including cost of Cement (PPC-Ramco, ACC, Ultratech, Nagarjuna & Jaypee) and all materials & men etc., complete
Providing 20 mm thick plaster with CM (1:4) to walls at all heights, lintel soffits, chajjas, projections, narrow bands, widths, in damaged floors and where ever required etc., including cost of Cement (PPC-Ramco, ACC, Ultratech, Nagarjuna & Jaypee) and all materials, tools, plant and labour, scaffolding arrangements and curing all as per specifications and directions of the engineer.
Removing old paint by machine scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. including necessary scaffolding and staging where ever required etc., complete all as directed.
Applying two coats of dampproof protect layer with Fosguard of fosroc make to the damaged areas of walls as per the directions of engineers incharge etc., Complete all as directed.
Providing Plain Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) in flooring, plinth protection and levelling courses with 20 mm nominal size stone aggregate finished with a floating coat of neat cement with coloured pigment and cement slurry, etc. complete and including cost of Cement (OPC 53 Grade- Ultratech, ACC, Nagarjuna, Maha etc.) and all materials & men etc., complete
Providing sal / igisha wood work in frames of doors and other frames, wrought framed, wooden rafters and fixed in position etc., after removing the damaged wooden frame etc., complete
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters supply and fixing of good quality of SS butt hinges of required size with necessary screws etc., complete (over all area of door shutter is to be measured).
Apply two coats of premium quality acrylic Interior emulsion paint over a coat of primer, required shade to wall surfaces from approved brands Asian paints (Royal shine), Berger (silky luxury) including necessary scaffolding and where ever specified by Engineer etc., complete all as directed.
Apply two coats of premium quality weather proofing arcylic Exterior emulsion paint over a coat of primer, required shade to wall surfaces from approved brands Asian paints (apex ultima), Berger (All guard) where ever specified by Engineer after through scrapping & cleaning of old surface including necessary scaffolding etc., complete
Apply two coats of white washing with Suryace / Hi-Tech Gold to internal and external walls including scrapping of old wall surface and necessary scaffolding and where ever specified by Engineer etc., complete all as directed.
Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests with 100 mm sand cast Iron P or S trap, conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required of Parryware / Hindware / Equivalent make including removal of old pan etc., complete.
Providing two (2) coats of synthetic enamel paint to doors, windows, structural steels, grills and wherever ever required for wooden surfaces and steel surfaces (after removing the rust by using wire brush or sand paper for steel surface / clean the surface of wood) of approved brand (Asian / Berger / Shalimar / Nerolac) and required colour to give an even shade on old work / new work including applying suitable (red oxide primer on steel surface) prime coat complete all as directed
Supplying and fixing of 20 mm thick granite inauguration plaque of size 1000x700mm polished granite slab with appropriate size of lettering in gold colour engraving with suitable colour and shade inauguration curtain including remote control operation etc; complete all as directed by Engineer.
Repairs to Public Library located in S2 & S3 quarters (part - A, for electrical works.)
Supply, Fixing, Testing & Commissioning of 40A DP Isolator, and 01 No's 1-phase 40A Digital Display Energy Meter of L&T make. along with Porcelian Cutout & Neutral Link (Make: Cona) arrangement on a wooden board all as directed by Engineer in Charge.
Supply, Fixing, Termination, Testing & Commissioning of 06 No's 20A 1P MCB along with suitable enclosure all as directed by Engineer in Charge.
Supply, Fixing, Termination of 12Way Modular Switch Board consisting of 08 No's 6A modular switches, 01 No 6A socket & 02 No Fan Step Regulator located in Main Corridor and Main Doctor Room all as directed by Engineer in Charge.
Supply, Fixing, Termination of 8Way Modular Switch Board consisting of 05No's 6A modular switches, 01 No 6A socket & 01 No Fan Step Regulator located in Doctor, Staff and Store room all as directed by Engineer in Charge.
Supply, Fixing, Termination of 3Way Modular Switch Board consisting of 01 no 16A Socket with Switch for Refrigerator / Heater / Medical Equipment in rooms all as directed by Engineer in Charge.
Supply, Fixing, Termination of 2Way Modular Switch Board consisting of 02No's 6A modular switches for exhaust fan and bulb in Bathroom all as directed by Engineer in Charge.
Supply, Fixing, Termination of 1Way Modular Switch Board consisting of 01No's 05A modular call bell switch & calling bell of Ding Dong Sound at Suitable Location all as directed by Engineer in Charge.
Supply, fix, test and commissioning of 1200mm sweep ceiling fan suitable length connection pipe, Modular Step type regulator all as directed by Engineer in Charge.
Supply, fix, test and commissioning of pin type brass holders with PVC enclosure of Anchor/ Cona/ equivalent make including 10W LED bulbs of Bajaj/ Philips complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of 20 W LED Batten lamps of make Havells / Phillips / Crompton complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of water tight bulhead fitting with pin type holder with 10W LED bulb complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of 180mm Exhaust Fan of make Havells / Phillips / Crompton complete all as directed by Engineer in Charge.
Supply, fix, test and commissioning of 20Amps MCB with metal box for 1.0 Tonne AC unit complete all as directed by Engineer in Charge.
Providing earth pits including Excavation, placing of 1.5 inch dia GI Pipe of suitable length along with necessary reducible sockets, nut & bolts, funnel and all other accessories, Salt, Charcoal/Coke, RCC Cover etc. as specified by the Engineer Incharge (including connection/drawing of Earth conductor up to earth electrode) all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for lights/ bulbs / fans & exhaust fans etc., with flush type switches for controlling these loads complete all as directed using 1.5 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs in Inch PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for all switch boards using 2.5 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs and 1 run for earth (green colour) in 1 Inch PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for all switch boards using 4.0 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs and 1 run for earth (green colour) in PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Removal of old fittings, battens and wirings in the quarters and handing over the same at Colony stores complete all as directed by Engineer in Charge.
Repairs to Veterinary Hospital located in HSL Colony Premises (part - B, for civil works)
Provide and lay water proofing treatment consisting of: (i) removing the existing damaged top layer of concrete and cleaning of roof slab. (ii) Repairing of all surface cracks wider than 3mm with polymer modified mortar prepared with Sikatop 77 acrylic polymer. (iii) Providing and laying cement plaster in CM 1:6 (where ever required to cover the undulations of slab surface) duly admixed with Sika Plastocrete Super @ 0.2% by weight of cement, over a bond coat of Sika Latex Cement Slurry to make the surface smooth and even at low levels. (iv) Application of priming coat of compatible bituminous primer Sika WP Shield Primer W or Shalikote @ 0.300 kg per sqm over the cleaned and prepared roof surface complete as per satisfaction of the Engineer-in-Charge. (v) Providing and laying STP(Shalimar) or Sika Atactic Polypropylene Polymer (APP) modified five layer prefabricated waterproofing membrane with thermal fusible properties on both side and having minimum thickness of 3.0mm and unit weight not less than 4.0 kg/sqm reinforced with non woven spun bonded polyester reinforcement @ 160 gm / sqm, <-50C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly, leaving no bare edge or end of APP membrane and finishing the surface with trowel or otherwise to obtain a uniform surface. The minimum side lap and end lap shall be kept at 75mm and 100 mm respectively. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane and membrane shall be laid over a coat of bituminous primer @ 0.300 kg./ltr per sqm made by the same membrane manufacture after necessary surface preparatory works such as cleaning the surface thoroughly and shall be finished in all respect as per direction of Engineer-in-Charge. (vi) Applying two coats of aluminium paint over the surface to protect from sun rays etc., complete
Chipping of unsound/weak concrete material from slabs & whereevr required etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and necessary scaffolding rrangements and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles etc., complete all as directed.
Supply and apply the NitoZinc primer of fosroc make to the existing prepared surface of reinforcing bars to protect from corrosion complete all as directed.
Providing building up of isolated damaged portions in ceilings & whereever required using polymer modified cementations mortar with cement sand ratio 1:3 using Nito bond SBR/ approved equivalent at the rate of 7lts/ bag of cement to an minimum thickness of 25 mm to 50 mm over the primed surface usisng Nito bond SBR in 1:1:3 by volume (Nitobond SBR :water: cement). Repair mortar has to be applied before priming coat dries, if the bonding compound dried it should be re- coated and curing the repair mortar after competion of repair work with Nito bond AR (1 part of water by volume) as a curing membarance at a coverage of 8-10 Sq.m / lit cost including scaffolding & staging work up to 5 M height and wherever necessary, all complete as specified and directed by the engineer in charge.
Pressure grouting in to the base slab of existing building by drilling the holes and grouting the mixture of Fosroc chemicals like cebex 100, nitto bond SBR or nitto bond AR and conplast 4211c with suitable proportions as per manfacture specifications and then seal the pocket by using Renderoc plug matarial complete all as directed by the engineer.
Providing 20 mm thick plaster with CM (1:4) to walls at all heights, lintel soffits, chajjas, projections, narrow bands, widths, in damaged floors and where ever required etc., including cost of Cement (PPC-Ramco, ACC, Ultratech, Nagarjuna & Jaypee) and all materials, tools, plant and labour, scaffolding arrangements and curing all as per specifications and directions of the engineer.
Removing old paint by machine scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. including necessary scaffolding and staging where ever required etc., complete all as directed.
Applying two coats of dampproof protect layer with Fosguard of fosroc make to the damaged areas of walls as per the directions of engineers incharge etc., Complete all as directed.
Providing Plain Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) in flooring, plinth protection and levelling courses with 20 mm nominal size stone aggregate finished with a floating coat of neat cement with coloured pigment and cement slurry, etc. complete and including cost of Cement (OPC 53 Grade- Ultratech, ACC, Nagarjuna, Maha etc.) and all materials & men etc., complete
Providing sal / igisha wood work in frames of doors and other frames, wrought framed, wooden rafters and fixed in position etc., after removing the damaged wooden frame etc., complete
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing 35 mm thick panelled cum glazed window shutters of second class teak wood with SS butt hinges of required size with necessary screws etc., after removing the existing window shutter etc., complete (over all area of window shutter is to be measured).
Providing and fixing ISI marked 35mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters supply and fixing of good quality of SS butt hinges of required size with necessary screws etc., complete (over all area of door shutter is to be measured).
Apply two coats of premium quality acrylic Interior emulsion paint over a coat of primer, required shade to wall surfaces from approved brands Asian paints (Royal shine), Berger (silky luxury) including necessary scaffolding and where ever specified by Engineer etc., complete all as directed.
Apply two coats of premium quality weather proofing arcylic Exterior emulsion paint over a coat of primer, required shade to wall surfaces from approved brands Asian paints (apex ultima), Berger (All guard) where ever specified by Engineer after through scrapping & cleaning of old surface including necessary scaffolding etc., complete
Repairs to existing Entrance MS gate by removing the old gate and add required bars / flat bars / angels and refix the same in position after repair works etc., and also provide a required MS aldrops and MS tower bolts and MS hinges for gates and making good to the walls etc., including all materials and welding consumables and equipment and labour etc., including priming coat with approved steel primer and two coats of enamel paint etc., complete all as directed by the Engineer Incharge.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer and two coats of enamel paint etc., all complete
Construction of Random rubble masonry with hard stone in foundation in CM (1:6) below plinth level and in ground floor, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) cost of cement (PPC-Ramco, ACC, Ultratech, Nagarjuna & Jaypee) including necessary scaffolding and all materials and pointing on wall surface etc., (Stone will be issued free by HSL, Contractor has to collect fro Colony maintenance stores and transport to the site including loading and unloading of materials)
Apply two coats of white washing with Suryace / Hi-Tech Gold to internal and external walls including scrapping of old wall surface and necessary scaffolding and where ever specified by Engineer etc., complete all as directed.
Providing two (2) coats of synthetic enamel paint to doors, windows, structural steels, grills and wherever ever required for wooden surfaces and steel surfaces (after removing the rust by using wire brush or sand paper for steel surface / clean the surface of wood) of approved brand (Asian / Berger / Shalimar / Nerolac) and required colour to give an even shade on old work / new work including applying suitable (red oxide primer on steel surface) prime coat complete all as directed
Supply of 110 mm dia UPVC (SWR) Soil and waste pipes conforming to IS : 13592 Type B, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes (supreme/ prince make) complete
Supply of 110 mm / 4 Inch dia UPVC(SWR) rain water downtake pipes (supreme/ prince make) conforming to IS : 13592 Type A, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes and required drain traps/ filters at roof level to arrest the leaves etc. complete
Supplying and fixing of 20 mm thick granite inauguration plaque of size 1000x700mm polished granite slab with appropriate size of lettering in gold colour engraving with suitable colour and shade inauguration curtain including remote control operation etc; complete all as directed by Engineer.
Repairs to Veterinary Hospital located in HSL Colony Premises (part - B, for electrical works.)
Supply, Fixing, Testing & Commissioning of 40A DP Isolator, and 01 No's 1-phase 40A Digital Display Energy Meter of L&T make. along with Porcelian Cutout & Neutral Link (Make: Cona) arrangement on a wooden board all as directed by Engineer in Charge.
Supply, Fixing, Termination, Testing & Commissioning of 06 No's 20A 1P MCB along with suitable enclosure all as directed by Engineer in Charge.
Supply, Fixing, Termination of 12Way Modular Switch Board consisting of 08 No's 6A modular switches, 01 No 6A/16A Twin socket & 02 No Fan Step Regulator located in Main Corridor and Main Doctor Room all as directed by Engineer in Charge.
Supply, Fixing, Termination of 8Way Modular Switch Board consisting of 05No's 6A modular switches, 01 No 6A/ 16A Twin Socket socket & 01 No Fan Step Regulator located in Doctor, Staff and Store room all as directed by Engineer in Charge.
Supply, Fixing, Termination of 3Way Modular Switch Board consisting of 01 no 6A/ 16A Twin Socket with Switch for Refrigerator / Heater / Medical Equipment in rooms all as directed by Engineer in Charge.
Supply, Fixing, Termination of 2Way Modular Switch Board consisting of 02No's 6A modular switches for exhaust fan and bulb in Bathroom all as directed by Engineer in Charge.
Supply, Fixing, Termination of 1Way Modular Switch Board consisting of 01No's 05A modular call bell switch & calling bell of Ding Dong Sound at Suitable Location all as directed by Engineer in Charge.
Supply, fix, test and commissioning of 1200mm sweep ceiling fan of Crompton / Orient make with suitable length connection pipe all as directed by Engineer in Charge
Supply, fix, test and commissioning of pin type brass holders with PVC enclosure of Anchor/ Cona/ equivalent make including 10W LED bulbs of Bajaj/ Philips complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of 20 W LED Batten lamps of make Havells / Phillips / Crompton complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of water tight bulk head wall light fitting with pin type holder with 10W LED bulb of Crompton / Havells / Phillips make complete all as directed by Engineer in Charge.
Supply, install, test and commissioning of 180mm Exhaust Fan of make Havells / Phillips / Crompton complete all as directed by Engineer in Charge.
Supply, fix, test and commissioning of 20Amps MCB with metal box for AC unit complete all as directed by Engineer in Charge.
Providing earth pits including Excavation, placing of 1.5 inch dia GI Pipe of suitable length along with necessary reducible sockets, nut & bolts, funnel and all other accessories, Salt, Charcoal/Coke, RCC Cover etc. as specified by the Engineer Incharge (including connection/drawing of Earth conductor up to earth electrode) all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for lights/ bulbs / fans & exhaust fans etc., with flush type switches for controlling these loads complete all as directed using 1.5 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs in Inch PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for all switch boards using 2.5 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs and 1 run for earth (green colour) in 1 Inch PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Supply of material required and providing concealed wiring for all switch boards using 4.0 Sq.mm FR PVC wire of Havels/Finolex make of 2 runs and 1 run for earth (green colour) in PVC conduit of sudhakar make with fixing clamps to be done all as directed by Engineer in Charge.
Removal of old fittings, battens and wirings in the quarters and handing over the same at Colony stores complete all as directed by Engineer in Charge.
Note : 1) The firm/Contractor shall arrange all necessary safety equipments like warning boards, safety belts and barricades etc., during execution of work. 2) The useful materials obtained during progress of work shall be handed over to Colony Maintenance Department unless otherwise specified/indicated. 3) The bidders/firms have to check the site conditions prior quoting for the tender. 4) All materials & labour including scaffolding materials is in contractor scope and applicable to all the schedule items, unless otherwise specified in that item.
MEGHA ENGINEERING AND INFRASTRUCTURE
RENUKA ENGINEERING WORKS
Sadiya Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .