| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance | L1 | Accepted-Finance being lowest | |
| 2 | L2₹5.0 L+₹1,349.72 (0.27%)Rejected-Finance | L2 | Rejected-Finance higher quoted amount in comparison of L1 | |
| 3 | L3₹5.4 L+₹38,283.72 (7.69%)Rejected-Finance | L3 | Rejected-Finance higher quoted amount in comparison of L1 | |
| 4 | L4₹5.5 L+₹53,728.12 (10.8%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance higher quoted amount in comparison of L1 | |
| 5 | L5₹6.5 L+₹1.5 L (30.3%)Rejected-Finance | L5 | Rejected-Finance higher quoted amount in comparison of L1 |
| Sl No | Description | Qty | Unit | M/s Shri Inder Construction Company L4 | Habib Traders L3 | M/s Rashid Mohammed L1 | Rakesh Choudhary Contractor L2 | SHRI K P ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out soft/loose soil complete. | 27.88 | Cum | 300 ₹8,364 | 500 ₹13,940 | 250 ₹6,970 | 200 ₹5,576 Lowest | 350 ₹9,758 |
| 2.00 | Returning, filling in excavated approved soil,(soft/loose soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete. | 11.46 | Cum | 300 ₹3,438 | 1,500 ₹17,190 | 60 ₹687.6 Lowest | 80 ₹916.8 | 130 ₹1,489.8 |
| 3.00 | Removing excavated soil exc 50 m but not exceeding 250 m and depositing where directed at a level not exceeding 1.5m above the starting point complete. | 15 | Cum | 250 ₹3,750 | 900 ₹13,500 | 65 ₹975 Lowest | 100 ₹1,500 | 320 ₹4,800 |
| 4.00 | M&L for PCC ( 1:4:8) Type D-2 using 40 mm graded aggregate as in fdn | 1.68 | Cum | 3,850 ₹6,468 | 4,500 ₹7,560 | 4,500 ₹7,560 | 2,800 ₹4,704 Lowest | 5,850 ₹9,828 |
| 5.00 | M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge. | 70 | Cum | 3,840 ₹2,68,800 | 3,500 ₹2,45,000 Lowest | 3,700 ₹2,59,000 | 4,300 ₹3,01,000 | 4,880 ₹3,41,600 |
| 6.00 | Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge. | 142.82 | Sqm | 70 ₹9,997.4 Lowest | 150 ₹21,423 | 80 ₹11,425.6 | 100 ₹14,282 | 250 ₹35,705 |
| 7.00 | M&L For Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering | 1.8 | Cum | 1,050 ₹1,890 | 2,500 ₹4,500 | 400 ₹720 Lowest | 700 ₹1,260 | 1,700 ₹3,060 |
| 8.00 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. | 1.8 | Cum | 1,050 ₹1,890 | 3,500 ₹6,300 | 900 ₹1,620 Lowest | 1,500 ₹2,700 | 2,250 ₹4,050 |
| 9.00 | M&L for 75mm thick PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in sub bases all as specified. | 12 | Sqm | 400 ₹4,800 | 250 ₹3,000 | 250 ₹3,000 | 200 ₹2,400 Lowest | 510 ₹6,120 |
| 10.00 | M&L rendering 15mm thick in 1:6 cement plaster on stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed. | 39.42 | Sqm | 270 ₹10,643.4 | 230 ₹9,066.6 Lowest | 250 ₹9,855 | 260 ₹10,249.2 | 310 ₹12,220.2 |
Tender Value
₹6.3 L
EMD Value
₹12,500
Closing Date
10 Jul 2025, 6:00 pmClosed
AGE I POKARAN
MILITARY ENGINEER SERVICES ASST GARRISON ENGINEER I POKARAN MILITARY STATION POKARAN-345021
PROVN OF PUMP OPERATOR ROOM CUM DRIVERS REST ROOM AT MAIN PUMP HOUSE UNDER AGE (I) POKARAN
2025_MES_713789_1
8301/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I POKARAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I POKARAN
₹12,500
Yes
11 Aug 2025
12 Jun 2025
17 Jul 2025
12 Jun 2025
10 Jul 2025
26 Jun 2025
13 Jun 2025 - 20 Jun 2025
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out soft/loose soil complete.
Returning, filling in excavated approved soil,(soft/loose soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil exc 50 m but not exceeding 250 m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for PCC ( 1:4:8) Type D-2 using 40 mm graded aggregate as in fdn
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses all as specified & directed by Engineer-in-Charge.
M&L For Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in sub bases all as specified.
M&L rendering 15mm thick in 1:6 cement plaster on stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L rendering 5mm thick in 1:3 cement plaster on ceiling of stone surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L rendering 15mm thick in 1:4 cement plaster on of stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L preparation of new wall surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer,including 3mm thick wall care putty on wall complete all as specified and directeded.
M&L preparation of new wall surface and applying three coat of white wash on surfaces of ceiling complete all as specified & directed by Engineer-in-charge.
M&L Finishing walls with Acrylic Smooth exterior paint of required hade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
S&F for Non- skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with screed bed 15 mm thick CM 1:6 complete all as specified & directed
. --Ditto-- all as per item No 16 above but as in skirting over & including 10mm thick backing coat of CM 1:4 all as specified.
S&F pressed steel frames for door with one are more rebates including necessary fixing lugs, hings lock strike plate etc
S&F 35mm thick factory made plain framed, panelled shutters (two panels) With lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated all as specified.
S & F, 35 mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
S&F 100mm size butt hinges, heavy wt, cold rolled mild steel complete.
S&F Aluminium anodised, barrel tower bolt of extruded section and fix of length 125mm
S&F Aluminium handles, cast type, anodised of size 150mm long.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F in repair decorative type curtain rod, stainless steel 25 mm dia with not less than 1 mm wall thickness complete all as specified and directed by Engineer-in-charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 150mm size.
S&F stainless steel wire 0.36mm normal dia of wire and average width of aparture 1.40mm complete all as specified & directed by Engineer-in-charge.
M&L for preparing new/previously untreated steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete.
M&L for sheet glass 4.00mm thick, ordinary quality and glazing with, rubber packing exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L for 5cm sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete complete all as specified and as directed by the Engineer-in-Charge
M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and fair w/o using extra cement
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete complete all as specified and as directed by the Engineer-in-Charge
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 25 to 55 mm as per the requirements all as directed by Engr-in-Charge.
M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC (WPC will be measured and paid separately as supply only)
Supply only integral Waterproofing compound.
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced and sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane all as speficied and directed. and applying one coat of aluminium paint @ 100ml/sqm on top of APP membrane to get uniform finish complete all as per specified and directed.
M&L point wiring complete with 1.5 Sqmm single core PVC insulated cable 1100 Volts grade multistranded copper conductor drawn through in PVC Conduit concealed on underground stone / brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point / Exhuast Fan / Bell point controlled by one 5 Amps One way switch and making good surfaces all as specified and directed by Engineer-in-Charge.
All as per Item No. 01 but for one 3 pin 5/6 Amps switch socket outlet on same board
All as per Item No. 01 but for one 3 pin 5/6 Amps switch socket outlet on independent board
All as per item No.1 above but wiring with 4.0 Sq mm and 2.5 sqmm for earth continuity for 3 pin 15/16 Amps switch socket combination
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed.
M&L switch piano flush type single pole one way 15 Amps complete all as specified and directed.
M&L Switch Socket Combination outlet, multipurpose, 2 pin 5 amps/3 pin 5 amps controled by one switch 5 amps, flush type complete all as specified and directed.
M&L Universal socket outlet with shutter, 5/15 amps controlled by one switch 15 amps, flush type complete all as specified and directed.
S&F Ceiling fan regulator Stepped type, 120 W-2 module AC 240 V all as specified and directed
M&L lamp holder insulated body with back plate suitable for battern fittings
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais all as specified
S&F Sheet Modular metal enclosure DB SPN 240 Volts 8 Way single door type with 200 Amps busbar for fixing of MCBs
S&F MCB Single pole and neutral, 40A, 240Volts AC all as specified
S&F MCB Single pole, 5-32A,240Volts AC all as specified
supply and fix LED Lamp Retro fit type 9 watts 230 V and all as specified by Engr-in-charge
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead all as specified
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm incl all as directed. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
Supply and spread approved Tibba sand for foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness will be measured for payment purpose
Supply and lay GI tubing , 40 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
Rakesh Choudhary Contractor (BID ID -3352840)
Habib Traders (BID ID -3349057)
M/s Shri Inder Construction Company (BID ID -3338623)
SHRI K P ENTERPRISES (BID ID -3353637)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .