Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.0 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹79.9 L+₹3.8 L (5.04%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹81.5 L+₹5.5 L (7.24%)Rejected-AOC CHETTIYADA KANNADY PO PULINCUNNOO ALAPPUZHA | L3 | Rejected-AOC Rejected | |
| 4 | L4₹82.1 L+₹6.1 L (8.00%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹84.6 L+₹8.6 L (11.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹84.7 L
EMD Value
₹50,000
Closing Date
28 Apr 2025, 6:00 pmClosed
Executive Engineer
Office of Executive Engineer K D division Mancombu
GENERAL Kannankari Padasekharam KP Flood control works to Kannankari Padasekharam in Neelamperoor Panchayath in Kuttanad Assembly Constituency General Civil Work
2025_Irrig_758920_1
IRR/KP/TR/7817/2024_5_1_1/1
Open Tender
Civil Works - Others
Item Rate
365 days
Neelamperoor Panchayath
No
13 documents required · 13 mandatory
₹2,760
Yes
₹50,000
Yes
9 Jul 2025
7 Apr 2025
30 Apr 2025
7 Apr 2025
28 Apr 2025
7 Apr 2025
7 Apr 2025 - 28 Apr 2025
Amount
Appendix 1 - Protection Works of Outer bunds
OD27293/2024-2025:Earthwork in excavation in or under water by mechanical means(Hydraulic excavator) /manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plain) including disposal of excavated earth, lead up to 50m and lift upto 1.5m,disposed earth to be leveled and neatly dressed. All kinds of soil. certificate:- Certified that the observed data is prepared by taking the rate and labour charges as per schedule of rates and has been prepared as per the actual observation at site
OD27292/2024-2025:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
OD27294/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble ( without bond stone)including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Appendix 2- Clay Bund Formation
OD27277/2024-2025:Earthwork in rough excavation banking excavated earth in layers not exceeding 20 cm in depth,breaking clods and dressing up in embackment for roads ,flood banks,marginal banks and guid banks with all leads and lifts in allkinds of soil(based on DSR 2.2.1-2.4-2.5+20% )under excavation in stiff kayal clay.
Appendix 3 -Construction and maintenance of Vachal
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
60.7.3:DISMANTLING DR - Dismanling , clearing away and carefully stacking materials useful for reuse for any thickness of walls in DR masonry including disposal of debris within a distance of 150m.
60.7.8:DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
OD36014/2024-2025:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
OD27276/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble ( without bond stone)including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Appendix 4 - Repair of Motorshed - 1 no.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD36202/2024-2025:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD38585/2024-2025:Filling with Quarry muck -Filling up low lying and water logged area with quarry muck, spreading in layers, levelling the top at site and consolidation by ramming etc. complete for improving the CBR value of subgrade.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Appendix 5 - Construction of Ramp - 4 Nos
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD36544/2024-2025:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD36551/2024-2025:Filling with Quarry Muck- Filling up low lying and water logged areas with quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc. complete for improving the CBR value of subgrade
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Appendix 6 - Maintenance of thoompu
OD37718/2024-2025:Providing drainage outlet by using best quality PV C Pipe 200mm dia including all cost and labour for cutting , placing etc
Joseph Thomas (BID ID -2203295)
JOSHY VARGHESE (BID ID -2203473)
James Thomas (BID ID -2203300)
VIJAY V NAIR (BID ID -2203480)
Bidder Name
sanalkumar v d
Joseph Thomas
James Thomas
JOSHY VARGHESE
VIJAY V NAIR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1233457.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .