Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance TC 13 352 4 KARTHIKA TOWER VANCHIYOOR P O TVM 695035 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695035 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,487
Closing Date
8 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical
The Executive Engineer Electrical, BSNL ELECTRICAL DIVISION I Floor, Central Telephone Exchange, Press Road, Statue,Trivandrum 695001
SITC of outdoor metering cublicle panel, HT cabling and related works at TE Kaithamukku (Revised)
2020_BSNL_53579_1
NIT_07_EDT_2020_21
Open Tender
Electrical Works
Item Rate
90 days
Trivandrum
as per documents attached
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer Cash, BSNL, Trivandrum SSA
₹16,487
Yes
12 Aug 2020
22 Jul 2020
11 Aug 2020
22 Jul 2020
8 Aug 2020
22 Jul 2020
90 days
Amount
SITC of outdoor metering cubicle made of powder coated 14 G sheet steel with suitable base frame comprising of 11KV, 630A, 25 KA for 1 sec, 350 MVA short circuit fault level Load Break Switch with earth switch, 1 no. resin cast fixed type PT - 3 ph, 25 VA, 11 KV/110V, Cl 0.2, 3 nos.Resin cast CTs - */5A, 10 VA, Cl 0.2S, S/F TOD Meter with Accuracy class 0.2S along with necessary supports, 630 A TP Copper bus, HT fuses - 3 nos. (suitable rating), space heater with thermostat, shunt trip coil, seal off bushings i/c erecting the metering cubicle with suitable angle iron frame and concrete foundation etc as required and as per attached specifications.(CTs, PT and TOD meter shall be of KSEB approved make only ) Note: 1. The CT-PT unit and the HT TOD meter shall be got tested from the local TMR as per KSEB norms.2 ) The fee for the CT/PT/TMR testing shall be paid by the agency and has to liaise with various KSEB offices for the completion of work .Nothing extra will be paid on this account by the department. 3. CT Ratio shall be as per the direction of Engineer in-Charge.
Supply of armoured, aluminium conductor XLPE power cable of 11 KV (earthed system) grade conforming to IS 7098(PartII) amended up to date as per the following size aluminium conductor XLPE UG cable with ISI mark complete as required. (a) 3 x 300 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a)Above 120 sq. mm and upto 400 sq. mm... Note: M Sand may be used instead of river sand.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a)Above 120 sq. mm and upto 400 sq. mm... Note: M Sand may be used instead of river sand.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. (a) Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Above 120 sq. mm and upto 400 sq. mm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : (a) 300 sqmm
Supply and fixing of suitable size MS channels, angles, flats for providing cable tray, support for runway etc including welding, grouting, painting with approved synthetic enamel paint after two coats of anti corrosive primer, providing mechanical fasteners/ suitable suspension arrangement etc complete as reqd.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete (a)100 mm dia
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse M-sand) at all levels
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine M-sand) at all levels
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse M-sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Demolishing cement concrete manually/ by mechanical means (3''/4''/6'' thick )including disposal of material within 50 metres lead as per direction of Engineer - in - charge
Providing M-sand for filling the duct chamber i/c transporting ,leading, filling etc as required
Hari and Gopal
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .